Verification of Set Up Dual-Chamber Pacemaker Electrical Parameters

The measurement on a dual-chamber cardiostimulator consists of the construction of a unit for the simulation of the cardiac action in a patient’s body. It has an adjustable amplitude (0 - 20 mV), frequency (0 - 100 Hz) and mark-space ratio. The system output impedance should be in the range of 200 - 2000 Ω. It is possible to add a defined noise into the output channel. It is further possible to measure the tolerance of sensing of the atrial and ventricular channel of the dual-chamber cardiostimulator DDDR.

[1]  Martin Cerny Movement Monitoring in the HomeCare System , 2009 .

[2]  John Jenq,et al.  Microsoft SQL server interface for mobile devices , 2007 .

[3]  Jan Unucka,et al.  TRANSCAT DSS architecture and modelling services , 2006 .

[4]  Vilém Srovnal,et al.  Design and development of embedded control system for a lime delivery machine , 2008, PDeS.

[5]  M. Penhaker,et al.  Global Courseware for Visualization and Processing Biosignals , 2009 .

[6]  Silvia Conforto,et al.  ECG - precordial leads reconstruction , 2009 .

[7]  Mordechai (Muki) Haklay,et al.  Usability Engineering for GIS: Learning from a Screenshot , 2008 .

[8]  Ondrej Krejcar,et al.  Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement , 2009 .

[9]  M. Penhaker,et al.  Sensitivity analysis and application of transducers , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[10]  Jakob Nielsen,et al.  Usability engineering , 1997, The Computer Science and Engineering Handbook.

[11]  Ondrej Krejcar,et al.  Complex Biomedical System with Mobile Clients , 2009 .

[12]  Marek Penhaker,et al.  Methods of Comparing ECG Reconstruction , 2009, 2009 2nd International Conference on Biomedical Engineering and Informatics.

[13]  Peter Brida,et al.  A Novel AoA Positioning Solution for Wireless Ad Hoc Networks Based on Six-Port Technology , 2009, WMNC/PWC.

[14]  Ondrej Krejcar,et al.  Mobile Monitoring Stations and Web Visualization of Biotelemetric System - Guardian II , 2009, EuropeComm.

[15]  M. Penhaker,et al.  The circadian cycle monitoring , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[16]  Martin Cerny,et al.  Design and Implementation of Textile Sensors for Biotelemetry Applications , 2008 .

[17]  M. Penhaker,et al.  The HomeCare and Circadian rhythm , 2008, 2008 International Conference on Information Technology and Applications in Biomedicine.

[18]  M. Penhaker,et al.  Using Frequency Analysis of Vibration for Detection of Epileptic Seizure , 2009 .

[19]  Martin Cerný,et al.  HomeCare — Smart embedded biotelemetry system , 2007 .

[20]  Jan Havlík,et al.  Human Body Motions Classification , 2009 .