The Effects of Thoracic Inhomogeneities on the Relationship Between Epicardial and Torso Potentials

This study examines the effects of the lungs, spine, sternum, and the anisotropic skeletal muscle layer on the relationship between torso and epicardial potentials. Boundary integral equations representing potentials on the epicardial surface, the torso surface, and the internal conductivity interfaces were solved yielding a set of transfer coefficients valid for any source inside the epicardium and for any conductivity configuration outside the epicardial surface. These transfer coefficients relate potentials on the torso to potentials on the epicardial surface. Calculated torso potentials are generated via the transfer coefficients and measured epicardial potentials for comparison to measured torso potentials. This comparison indicates whether including the thoracic inhomogeneities improves attainable accuracy in calculations relating torso potentials to epicardial potentials.

[1]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. , 1948, British heart journal.

[2]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. Part II , 1947, British heart journal.

[3]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. , 1948, British heart journal.

[4]  C. V. Nelson,et al.  HUMAN THORAX POTENTIALS , 1957, Annals of the New York Academy of Sciences.

[5]  D. B. Geselowitz,et al.  Multipole Representation for an Equivalent Cardiac Generator , 1960, Proceedings of the IRE.

[6]  H. Gelernter,et al.  A MATHEMATICAL-PHYSICAL MODEL OF THE GENESIS OF THE ELECTROCARDIOGRAM. , 1964, Biophysical journal.

[7]  R. Barr,et al.  Determining surface potentials from current dipoles, with application to electrocardiography. , 1966, IEEE transactions on bio-medical engineering.

[8]  S. Rush,et al.  Qualitative effects of thoracic resistivity variations on the interpretation of electrocardiograms: the low resistance surface layer. , 1968, American Heart Journal.

[9]  Electrocardiographic changes in pulmonary emphysema: effects of experimentally induced over-inflation of the lungs on QRS complexes. , 1974, American heart journal.

[10]  R. Barr,et al.  Relating Epicardial to Body Surface Potential Distributions by Means of Transfer Coefficients Based on Geometry Measurements , 1977, IEEE Transactions on Biomedical Engineering.

[11]  D. Geselowitz,et al.  Simulation Studies of the Electrocardiogram: I. The Normal Heart , 1978, Circulation research.

[12]  R. Plonsey,et al.  The Effects of Variations in Conductivity and Geometrical Parameters on the Electrocardiogram, Using an Eccentric Spheres Model , 1979, Circulation research.

[13]  R. Plonsey,et al.  The Eccentric Spheres Model as the Basis for a Study of the Role of Geometry and Inhomogeneities in Electrocardiography , 1979, IEEE Transactions on Biomedical Engineering.

[14]  R. Plonsey,et al.  A Comparison of Volume Conductor and Source Geometry Effects on Body Surface and Epicardial Potentials , 1980, Circulation research.

[15]  R. Plonsey,et al.  The Effect of High Lung Conductivity on Electrocardiographic Potentials: Results from Human Subjects Undergoing Bronchopulmonary Lavage , 1982, Circulation.

[16]  R. Gulrajani,et al.  A Simulation Study of the Effects of Torso Inhomogeneities on Electrocardiographic Potentials, using Realistic Heart and Torso Models , 1983, Circulation research.