Configurable bandwidth imaging spectrometer based on acousto-optic tunable filter

This paper presents a new portable instrument called Autonomous Tunable Filtering System (ATFS), developed for highly customisable imaging spectrometry in the VIS-NIR range. The ATFS instrument consists of an Acousto-Optic Tunable Filter (AOTF), an optical system, a Radio Frequency (RF) driver based on a Direct Digital Synthesiser (DDS) and control software. The ATFS can be attached to a variety of high-performance monochrome cameras. The system works as a spectral bandpass filter whose wavelength can be selected between 400nm and 1000nm and whose bandwidth can be adjusted between 4nm and 50nm. The filter can be tuned electronically at a very high speed and accuracy, thanks to the DDS versatility. The control software synchronises the camera with the RF generation and implements a smart auto-exposure algorithm that maximises the dynamic range of the instrument for each band. The software can take a set of spectral images sequentially and save them in ENVI® multispectral format or as multiple TIFF images. The system has been validated using a reference point spectrometer. An optional acquisition procedure has been developed, based on the acquisition of dark and white Spectralon® reference images, in order to use the system in applications involving quantitative (reflectance) measurements. Procedures have been established in order to fully calibrate the instrument. The system has been demonstrated in a real world application, which uses the ATFS to map the leaf chlorophyll content from multispectral reflectance images.

[1]  C. François,et al.  Towards universal broad leaf chlorophyll indices using PROSPECT simulated database and hyperspectral reflectance measurements , 2004 .

[2]  John A. Gamon,et al.  Assessing leaf pigment content and activity with a reflectometer , 1999 .

[3]  G. A. Blackburn,et al.  Quantifying Chlorophylls and Caroteniods at Leaf and Canopy Scales: An Evaluation of Some Hyperspectral Approaches , 1998 .

[4]  P. Thenkabail,et al.  Hyperspectral Vegetation Indices and Their Relationships with Agricultural Crop Characteristics , 2000 .

[5]  C. Creaser,et al.  Analytical applications of spectroscopy , 1988 .

[6]  Luis Gómez-Chova,et al.  400 - to 1000 - Nm Imaging Spectrometer Based on Acousto-optic Tunable Filters , 2006, J. Electronic Imaging.

[7]  Yuri A. Gritz,et al.  Relationships between leaf chlorophyll content and spectral reflectance and algorithms for non-destructive chlorophyll assessment in higher plant leaves. , 2003, Journal of plant physiology.

[8]  R. Tateishi,et al.  Relationships between percent vegetation cover and vegetation indices , 1998 .

[9]  Andrew D. Richardson,et al.  An evaluation of noninvasive methods to estimate foliar chlorophyll content , 2002 .

[10]  Nahum Gat,et al.  Imaging spectroscopy using tunable filters: a review , 2000, SPIE Defense + Commercial Sensing.

[11]  Neelam Gupta,et al.  Telecentric confocal optics for aberration correction of acousto-optic tunable filters. , 2004, Applied optics.

[12]  Jieping Xu,et al.  Acousto-optic devices , 1992 .

[13]  I. C. Chang,et al.  Noncollinear acousto‐optic filter with large angular aperture , 1974 .

[14]  R. Stroud,et al.  Acousto-optic devices : principles, design, and applications , 1992 .

[15]  A. Gitelson,et al.  Spectral reflectance changes associated with autumn senescence of Aesculus hippocastanum L. and Acer platanoides L. leaves. Spectral features and relation to chlorophyll estimation , 1994 .

[16]  D. E. Bowker,et al.  Spectral reflectances of natural targets for use in remote sensing studies , 1985 .