Examination of the reliability of an inertial sensor-based gait analysis system

Abstract Gait analysis is an important and useful part of the daily therapeutic routine. InvestiGAIT, an inertial sensor-based system, was developed for using in different research projects with a changing number and position of sensors and because commercial systems do not capture the motion of the upper body. The current study is designed to evaluate the reliability of InvestiGAIT consisting of four off-the-shelf inertial sensors and in-house capturing and analysis software. Besides the determination of standard gait parameters, the motion of the upper body (pelvis and spine) can be investigated. Kinematic data of 25 healthy individuals (age: 25.6±3.3 years) were collected using a test-retest design with 1 week between measurement sessions. We calculated different parameters for absolute [e.g. limits of agreement (LoA)] and relative reliability [intraclass correlation coefficients (ICC)]. Our results show excellent ICC values for most of the gait parameters. Midswing height (MH), height difference (HD) of initial contact (IC) and terminal contact (TC) and stride length (SL) are the gait parameters, which did not exhibit acceptable values representing absolute reliability. Moreover, the parameters derived from the motion of the upper body (pelvis and spine) show excellent ICC values or high correlations. Our results indicate that InvestiGAIT is suitable for reliable measurement of almost all the considered gait parameters.

[1]  F. Horak,et al.  Role of Body-Worn Movement Monitor Technology for Balance and Gait Rehabilitation , 2014, Physical Therapy.

[2]  Adrian Burns,et al.  An adaptive gyroscope-based algorithm for temporal gait analysis , 2010, Medical & Biological Engineering & Computing.

[3]  Martina Mancini,et al.  Objective biomarkers of balance and gait for Parkinson's disease using body‐worn sensors , 2013, Movement disorders : official journal of the Movement Disorder Society.

[4]  Kamiar Aminian,et al.  3D gait assessment in young and elderly subjects using foot-worn inertial sensors. , 2010, Journal of biomechanics.

[5]  R. Moe-Nilssen Test-retest reliability of trunk accelerometry during standing and walking. , 1998, Archives of physical medicine and rehabilitation.

[6]  Andrea Mannini,et al.  Gait phase detection and discrimination between walking-jogging activities using hidden Markov models applied to foot motion data from a gyroscope. , 2012, Gait & posture.

[7]  J. Richards,et al.  The measurement of human motion: A comparison of commercially available systems , 1999 .

[8]  Hylton B Menz,et al.  Accelerometry: a technique for quantifying movement patterns during walking. , 2008, Gait & posture.

[9]  P H Veltink,et al.  Detection of the onset of gait initiation using kinematic sensors and EMG in transfemoral amputees. , 2014, Gait & posture.

[10]  R. Moe-Nilssen,et al.  Test-retest reliability of trunk accelerometric gait analysis. , 2004, Gait & posture.

[11]  Yu-Liang Hsu,et al.  Gait and Balance Analysis for Patients With Alzheimer's Disease Using an Inertial-Sensor-Based Wearable Instrument , 2014, IEEE Journal of Biomedical and Health Informatics.

[12]  Michael W. Whittle,et al.  Clinical gait analysis: A review , 1996 .

[13]  Alexander Horsch,et al.  Description of spatio-temporal gait parameters in elderly people and their association with history of falls: results of the population-based cross-sectional KORA-Age study , 2015, BMC Geriatrics.

[14]  C. Terwee,et al.  When to use agreement versus reliability measures. , 2006, Journal of clinical epidemiology.

[15]  Angelo M. Sabatini,et al.  Quaternion-based strap-down integration method for applications of inertial sensing to gait analysis , 2006, Medical and Biological Engineering and Computing.

[16]  Katja Orlowski,et al.  Evaluation of KINECT and SHIMMER Sensors for Detection of Gait Parameters , 2013, BIOSIGNALS.

[17]  Sheldon R Simon,et al.  Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. , 2004, Journal of biomechanics.

[18]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[19]  F. Coutts,et al.  Gait analysis in the therapeutic environment. , 1999, Manual therapy.

[20]  R Senden,et al.  Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system. , 2016, Medical engineering & physics.

[21]  Christopher R. Harris,et al.  Accurate and Reliable Gait Cycle Detection in Parkinson's Disease , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[22]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[23]  C. Lamoth,et al.  Gait and cognition: the relationship between gait stability and variability with executive function in persons with and without dementia. , 2012, Gait & posture.

[24]  W. Zijlstra,et al.  A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking. , 2008, Gait & posture.

[25]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[26]  Dara Meldrum,et al.  Test-retest reliability of three dimensional gait analysis: including a novel approach to visualising agreement of gait cycle waveforms with Bland and Altman plots. , 2014, Gait & posture.

[27]  Daniel Tik-Pui Fong,et al.  The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review , 2010, Sensors.

[28]  Wiebren Zijlstra,et al.  Subjects with hip osteoarthritis show distinctive patterns of trunk movements during gait-a body-fixed-sensor based analysis , 2012, Journal of NeuroEngineering and Rehabilitation.

[29]  Graham K. Kerr,et al.  Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces , 2014, PloS one.

[30]  F. Horak,et al.  Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed. , 2012, Gait & posture.

[31]  D. Cicchetti Guidelines, Criteria, and Rules of Thumb for Evaluating Normed and Standardized Assessment Instruments in Psychology. , 1994 .

[32]  Begonya Garcia-Zapirain,et al.  Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications , 2014, Sensors.

[33]  Steven Morrison,et al.  Reliability of segmental accelerations measured using a new wireless gait analysis system. , 2006, Journal of biomechanics.

[34]  Pedram Azad Visual Perception for Manipulation and Imitation in Humanoid Robots , 2008, Cognitive Systems Monographs.

[35]  Navrag B. Singh,et al.  Kinematic measures for assessing gait stability in elderly individuals: a systematic review , 2011, Journal of The Royal Society Interface.

[36]  Ralf Kauert,et al.  Reliabilitätsstudie zum Ganganalysesystem RehaWatch / Reliability of the novel gait analysis system RehaWatch , 2010, Biomedizinische Technik. Biomedical engineering.

[37]  Daniel Hamacher,et al.  Towards clinical application: repetitive sensor position re-calibration for improved reliability of gait parameters. , 2014, Gait & posture.

[38]  Katja Orlowski,et al.  Evaluation of Gait Parameters Determined by InvestiGAIT against a Reference System , 2016, BIOSIGNALS.

[39]  R. Fitzpatrick,et al.  Age-related differences in walking stability. , 2003, Age and ageing.

[40]  K. Holt,et al.  Gait Characteristics of Elderly People With a History of Falls: A Dynamic Approach , 2006, Physical Therapy.

[41]  Daniel Hamacher,et al.  A cognitive dual task affects gait variability in patients suffering from chronic low back pain , 2014, Experimental Brain Research.