Fast tomosynthesis for lung cancer detection using the SBDX geometry

Radiology-based lung-cancer detection is a high-contrast imaging task, consisting of the detection of a small mass of tissue within much lower density lung parenchyma. This imaging task requires removal of confounding image details, fast image acquisition (< 0.1 s for pericardial region), low dose (comparable to a chest x-ray), high resolution (< 0.25 mm in-plane) and patient positioning flexibility. We present an investigation of tomosynthesis, implemented using the Scanning-Beam Digital X-ray System (SBDX), to achieve these goals. We designed an image-based computer model of tomosynthesis using a high-resolution (0.15-mm isotropic voxels), low-noise CT volume image of a lung phantom, numerically added spherical lesions and convolution-based tomographic blurring. Lesion visibility was examined as a function of half-tomographic angle for 2.5 and 4.0 mm diameter lesions. Gaussian distributed noise was added to the projected images. For lesions 2.5 mm and 4.0 mm in diameter, half-tomographic angles of at least 6° and 9° respectively were necessary before visualization of the lesions improved. The addition of noise for a dose equivalent to 1/10 that used for a standard chest radiograph did not significantly impair lesion detection. The results are promising, indicating that lung-cancer detection using a modified SBDX system is possible.

[1]  S Sone,et al.  Visibility of small peripheral lung cancers on chest radiographs: influence of densitometric parameters, CT values and tumour type. , 2001, The British journal of radiology.

[2]  R. Coleman,et al.  PET in lung cancer. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Steven K. Feiner,et al.  Computer graphics: principles and practice (2nd ed.) , 1990 .

[4]  S. Sone,et al.  Characteristics of small lung cancers invisible on conventional chest radiography and detected by population based screening using spiral CT. , 2000, The British journal of radiology.

[5]  R. Munden,et al.  Small pulmonary lesions detected at CT: clinical importance. , 1997, Radiology.

[6]  Edward G. Solomon,et al.  Scanning-beam digital x-ray (SBDX) system for cardiac angiography , 1999, Medical Imaging.

[7]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[8]  Taylor Murray,et al.  Cancer statistics, 2000 , 2000, CA: a cancer journal for clinicians.

[9]  W C Black,et al.  CT screening for lung cancer: not ready for routine practice. , 2001, Radiology.

[10]  H Rusinek,et al.  Pulmonary nodule detection: low-dose versus conventional CT. , 1998, Radiology.

[11]  H. Ohmatsu,et al.  Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. , 1996, Radiology.

[12]  E. Samei,et al.  Simulation of subtle lung nodules in projection chest radiography. , 1997, Radiology.

[13]  A. Gazdar,et al.  Early detection of lung cancer: clinical perspectives of recent advances in biology and radiology. , 2001, Clinical cancer research : an official journal of the American Association for Cancer Research.

[14]  Robert E. Melen,et al.  CdZnTe detector array for a scanning-beam digital x-ray system , 1999, Medical Imaging.

[15]  O S Miettinen,et al.  CT screening for lung cancer: coping with nihilistic recommendations. , 2001, Radiology.

[16]  D S Paik,et al.  Display modes for CT colonography. Part I. Synthesis and insertion of polyps into patient CT data. , 1999, Radiology.

[17]  H. Steinert,et al.  PET in lung cancer. , 2005, Chang Gung medical journal.

[18]  E Samei,et al.  Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. , 1999, Radiology.