Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review.

Digital volume correlation (DVC) provides experimental measurements of displacements and strains throughout the interior of porous materials such as trabecular bone. It can provide full-field continuum- and tissue-level measurements, desirable for validation of finite element models, by comparing image volumes from subsequent µCT scans of a sample in unloaded and loaded states. Since the first application of DVC for measurement of strain in bone tissue, subsequent reports of its application to trabecular bone cores up to whole bones have appeared within the literature. An "optimal" set of procedures capable of precise and accurate measurements of strain, however, still remains unclear, and a systematic review focussing explicitly on the increasing number of DVC algorithms applied to bone or structurally similar materials is currently unavailable. This review investigates the effects of individual parameters reported within individual studies, allowing to make recommendations for suggesting algorithms capable of achieving high accuracy and precision in displacement and strain measurements. These recommendations suggest use of subsets that are sufficiently large to encompass unique datasets (e.g. subsets of 500 µm edge length when applied to human trabecular bone cores, such as cores 10mm in height and 5mm in diameter, scanned at 15 µm voxel size), a shape function that uses full affine transformations (translation, rotation, normal strain and shear strain), the robust normalized cross-correlation coefficient objective function, and high-order interpolation schemes. As these employ computationally burdensome algorithms, researchers need to determine whether they have the necessary computational resources or time to adopt such strategies. As each algorithm is suitable for parallel programming however, the adoption of high precision techniques may become more prevalent in the future.

[1]  Erwin Hack,et al.  Full Three‐Dimensional Strain Measurements on Wood Exposed to Three‐Point Bending: Analysis by Use of Digital Volume Correlation Applied to Synchrotron Radiation Micro‐Computed Tomography Image Data , 2010 .

[2]  I. Jandejsek,et al.  Precise strain measurement in complex materials using Digital Volumetric Correlation and time lapse micro-CT data , 2011 .

[3]  Mgd Marc Geers,et al.  Computing strain fields from discrete displacement fields in 2D-solids , 1996 .

[4]  G. Ravichandran,et al.  Three-dimensional Full-field Measurements of Large Deformations in Soft Materials Using Confocal Microscopy and Digital Volume Correlation , 2007 .

[5]  M Viceconti,et al.  Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur. , 2008, Journal of biomechanics.

[6]  R. Müller,et al.  Time-lapsed microstructural imaging of bone failure behavior. , 2004, Journal of biomechanics.

[7]  Ralph Müller,et al.  Design and implementation of a novel mechanical testing system for cellular solids. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[8]  E. Morgan,et al.  Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. , 2007, Journal of biomechanics.

[9]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[10]  B. Bay,et al.  Digital volume correlation: Three-dimensional strain mapping using X-ray tomography , 1999 .

[11]  W C Hayes,et al.  Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus. , 1994, Journal of biomechanics.

[12]  M Viceconti,et al.  Structural parameters and mechanical strength of cancellous bone in the femoral head in osteoarthritis do not depend on age. , 2007, Bone.

[13]  Egon Perilli,et al.  Micro-CT examination of human bone: from biopsies towards the entire organ. , 2012, Annali dell'Istituto superiore di sanita.

[14]  P. Thurner,et al.  Mechanical properties of single bovine trabeculae are unaffected by strain rate. , 2011, Journal of biomechanics.

[15]  Gioacchino Viggiani,et al.  Volumetric Digital Image Correlation Applied to X‐ray Microtomography Images from Triaxial Compression Tests on Argillaceous Rock , 2007 .

[16]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[17]  J H Keyak,et al.  Validation of an automated method of three-dimensional finite element modelling of bone. , 1993, Journal of biomedical engineering.

[18]  John Currey,et al.  Measurement of the Mechanical Properties of Bone: A Recent History , 2009, Clinical orthopaedics and related research.

[19]  Tony M Keaveny,et al.  Locations of bone tissue at high risk of initial failure during compressive loading of the human vertebral body. , 2007, Bone.

[20]  M. M. Rashid,et al.  Digital volume correlation including rotational degrees of freedom during minimization , 2002 .

[21]  J. Paul Robinson,et al.  Local, three-dimensional strain measurements within largely deformed extracellular matrix constructs. , 2004, Journal of biomechanical engineering.

[22]  R Huiskes,et al.  Comparison of micro-level and continuum-level voxel models of the proximal femur. , 2006, Journal of biomechanics.

[23]  R. Müller,et al.  Towards validation of computational analyses of peri-implant displacements by means of experimentally obtained displacement maps , 2011, Computer methods in biomechanics and biomedical engineering.

[24]  Brian K. Bay,et al.  Methods and applications of digital volume correlation , 2008 .

[25]  Paul E Barbone,et al.  Digital Volume Correlation for Study of the Mechanics of Whole Bones. , 2012, Procedia IUTAM.

[26]  I. Jandejsek,et al.  Evaluation of strain field in microstructures using micro-CT and digital volume correlation , 2011 .

[27]  R. Huiskes,et al.  A three-dimensional digital image correlation technique for strain measurements in microstructures. , 2004, Journal of biomechanics.

[28]  Stéphane Roux,et al.  3D analysis from micro-MRI during in situ compression on cancellous bone. , 2009, Journal of biomechanics.

[29]  S. Roux,et al.  Comparison of Local and Global Approaches to Digital Image Correlation , 2012 .

[30]  T. Keaveny,et al.  Yield strain behavior of trabecular bone. , 1998, Journal of biomechanics.

[31]  S. Goldstein,et al.  Evaluation of a microcomputed tomography system to study trabecular bone structure , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[32]  W. F. Ranson,et al.  Determination of displacements using an improved digital correlation method , 1983, Image Vis. Comput..

[33]  B. Bay,et al.  Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. , 2006, Journal of biomechanical engineering.

[34]  W. H. Peters,et al.  Application of an optimized digital correlation method to planar deformation analysis , 1986, Image Vis. Comput..

[35]  M. A. Sutton,et al.  Systematic errors in digital image correlation caused by intensity interpolation , 2000 .

[36]  M. Viceconti,et al.  The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. , 2007, Medical engineering & physics.

[37]  Michael R Hardisty,et al.  Whole bone strain quantification by image registration: a validation study. , 2009, Journal of biomechanical engineering.

[38]  Anand Asundi,et al.  Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review , 2009 .

[39]  G. Niebur,et al.  High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. , 2000, Journal of biomechanics.

[40]  T. McMahon,et al.  Trabecular bone exhibits fully linear elastic behavior and yields at low strains. , 1994, Journal of biomechanics.