Rationale of Dead Space Measurement by Volumetric Capnography

Dead space is the portion of a tidal volume that does not participate in gas exchange because it does not get in contact with blood flowing through the pulmonary capillaries. It is commonly calculated using volumetric capnography, the plot of expired carbon dioxide (CO2) versus tidal volume, which is an easy bedside assessment of the inefficiency of a particular ventilatory setting. Today, Bohr's original dead space can be calculated in an entirely noninvasive and breath-by-breath manner as the mean alveolar partial pressure of CO2 (PACO2) which can now be determined directly from the capnogram. The value derived from Enghoff's modification of Bohr's formula (using PaCO2 instead of PACO2) is a global index of the inefficiency of gas exchange rather than a true “dead space” because it is influenced by all causes of ventilation/perfusion mismatching, from real dead space to shunt. Therefore, the results obtained by Bohr's and Enghoff's formulas have different physiological meanings and clinicians must be conscious of such differences when interpreting patient data. In this article, we describe the rationale of dead space measurements by volumetric capnography and discuss its main clinical implications and the misconceptions surrounding it.

[1]  Peter D Wagner Causes of a high physiological dead space in critically ill patients , 2008, Critical care.

[2]  G. Hedenstierna,et al.  Monitoring dead space during recruitment and PEEP titration in an experimental model , 2006, Intensive Care Medicine.

[3]  D. Gómez A PHYSICO-MATHEMATICAL STUDY OF LUNG FUNCTION IN NORMAL SUBJECTS AND IN PATIENTS WITH OBSTRUCTIVE PULMONARY DISEASES. , 1965, Medicina thoracalis.

[4]  C. Mélot,et al.  Contribution of multiple inert gas elimination technique to pulmonary medicine. 5. Ventilation-perfusion relationships in acute respiratory failure. , 1994, Thorax.

[5]  J. Severinghaus,et al.  Alveolar Dead Space as an Index of Distribution of Blood Flow in Pulmonary Capillaries , 1957 .

[6]  P. Suter,et al.  Optimum end-expiratory airway pressure in patients with acute pulmonary failure. , 1975, The New England journal of medicine.

[7]  M. J. Turner,et al.  Systematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram. , 2007, British journal of anaesthesia.

[8]  J. Pappenheimer,et al.  Components of the respiratory dead space and their variation with pressure breathing and with bronchoactive drugs. , 1955, Journal of applied physiology.

[9]  R. Rodríguez-Roisín,et al.  Contribution of multiple inert gas elimination technique to pulmonary medicine , 1994 .

[10]  Franck Verschuren,et al.  Volumetric capnography as a screening test for pulmonary embolism in the emergency department. , 2004, Chest.

[11]  J. Richardson,et al.  Effect of breathing pattern on gas mixing in a model with asymmetrical alveolar ducts. , 1985, Journal of applied physiology.

[12]  I. Cheifetz,et al.  Deadspace to tidal volume ratio predicts successful extubation in infants and children , 2000, Critical care medicine.

[13]  R W Glenny,et al.  Fractal nature of regional ventilation distribution. , 2000, Journal of applied physiology.

[14]  C. Bohr Ueber die Lungenathmung1 , 1891 .

[15]  D. Duncalf,et al.  Effect of anatomic shunt on physiologic deadspace-to-tidal volume ratio--a new equation. , 1969, Anesthesiology.

[16]  R. Riley,et al.  Analysis of factors affecting partial pressures of oxygen and carbon dioxide in gas and blood of lungs; theory. , 1951, Journal of applied physiology.

[17]  S. Böhm,et al.  Alveolar recruitment improves ventilatory efficiency of the lungs during anesthesia , 2004, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[18]  C. G. Douglas,et al.  The carbon dioxide stimulus to breathing in severe exercise , 1954, The Journal of physiology.

[19]  A. Krogh,et al.  On the average composition of the alveolar air and its variations during the respiratory cycle , 1914, The Journal of physiology.

[20]  A. B. Crawford,et al.  Convection- and diffusion-dependent ventilation maldistribution in normal subjects. , 1985, Journal of applied physiology.

[21]  L. A. Engel,et al.  Model analysis of intra-acinar gas exchange. , 1985, Respiration physiology.

[22]  Gerardo Tusman,et al.  Validation of Bohr dead space measured by volumetric capnography , 2011, Intensive Care Medicine.

[23]  N. Burki The dead space to tidal volume ratio in the diagnosis of pulmonary embolism. , 1986, The American review of respiratory disease.

[24]  R. Riley,et al.  Ideal alveolar air and the analysis of ventilation-perfusion relationships in the lungs. , 1949, Journal of applied physiology.

[25]  J B West,et al.  Measurement of continuous distributions of ventilation-perfusion ratios: theory. , 1974, Journal of applied physiology.

[26]  R. Benattar,et al.  Time‐resolved evolution of laser‐produced plasmas in spherical expansion regime , 1983 .

[27]  P. Breen,et al.  Comparison of End-Tidal PCO2 and Average Alveolar Expired PCO2 During Positive End-Expiratory Pressure , 1996, Anesthesia and analgesia.

[28]  S. Böhm,et al.  Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III , 2009, Journal of Clinical Monitoring and Computing.

[29]  D V BATES,et al.  The respiratory dead space measured by single breath analysis of oxygen, carbon dioxide, nitrogen or helium. , 1954, The Journal of clinical investigation.

[30]  M F Roizen,et al.  Simple computer measurement of pulmonary VCO2 per breath. , 1992, Journal of applied physiology.

[31]  W. O. Fenn,et al.  Alveolar CO2 during the respiratory cycle. , 1952, Journal of applied physiology.

[32]  W. S. Fowler Lung function studies; the respiratory dead space. , 1948, The American journal of physiology.

[33]  L. L. Shik [Respiratory dead space]. , 1976, Fiziologicheskii zhurnal SSSR imeni I. M. Sechenova.

[34]  G. Hedenstierna,et al.  Assessing dead space. A meaningful variable? , 2006, Minerva anestesiologica.

[35]  J. Severinghaus,et al.  Alveolar dead space as an index of distribution of blood flow in pulmonary capillaries. , 1958, Journal of applied physiology.

[36]  E. Klein The Bacteria of Swine Plague , 1884, The Journal of physiology.

[37]  A. E. Clark-Kennedy,et al.  On the fluctuation in the composition of the alveolar air during the respiratory cycle in muscular exercise , 1928, The Journal of physiology.

[38]  M Paiva,et al.  Model simulations of gas mixing and ventilation distribution in the human lung. , 1990, Journal of applied physiology.

[39]  Leopoldo C Cancio,et al.  Ventilation-perfusion relationships following experimental pulmonary contusion. , 2007, Journal of applied physiology.

[40]  R Fletcher Deadspace, invasive and non-invasive. , 1985, British journal of anaesthesia.

[41]  G. Cumming,et al.  Alveolar gas mixing efficiency in the human lung. , 1982, Clinical science.

[42]  J S Haldane,et al.  The regulation of the lung‐ventilation , 1905, The Journal of physiology.

[43]  Computation of the boundary conditions for diffusion in the human lung. , 1972, Computers and biomedical research, an international journal.

[44]  S. Bohm,et al.  Compliance and Dead Space Fraction Indicate an Optimal Level of Positive End-Expiratory Pressure After Recruitment in Anesthetized Patients , 2008, Anesthesia and analgesia.

[45]  R Fletcher,et al.  Clinical studies of gas exchange during ventilatory support--a method using the Siemens-Elema CO2 analyzer. , 1980, British journal of anaesthesia.

[46]  R Fletcher,et al.  The concept of deadspace with special reference to the single breath test for carbon dioxide. , 1981, British journal of anaesthesia.

[47]  E. Swenson,et al.  Contribution of continuing gas exchange to phase III exhaled PCO2 and PO2 profiles. , 1987, Journal of applied physiology.

[48]  Rian,et al.  PULMONARY DEAD-SPACE FRACTION AS A RISK FACTOR FOR DEATH IN THE ACUTE RESPIRATORY DISTRESS SYNDROME , 2002 .

[49]  M. Matthay,et al.  Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method. , 2005, Respiratory care.

[50]  J. Kline,et al.  Diagnostic accuracy of a bedside D-dimer assay and alveolar dead-space measurement for rapid exclusion of pulmonary embolism: a multicenter study. , 2001, JAMA.

[51]  Giovanni Gandini,et al.  Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. , 2007, American journal of respiratory and critical care medicine.

[52]  S. Bohm,et al.  Effect of pulmonary perfusion on the slopes of single-breath test of CO2. , 2005, Journal of applied physiology.

[53]  L. A. Engel Gas mixing within the acinus of the lung. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[54]  A. Dubois Alveolar CO2 and O2 during breath holding, expiration, and inspiration. , 1952, Journal of applied physiology.

[55]  G. Hedenstierna,et al.  The effect of anaesthesia and intermittent positive pressure ventilation with different frequencies on the anatomical and alveolar deadspace. , 1975, British journal of anaesthesia.

[56]  G Cumming,et al.  Functional consequences of airway morphology. , 1968, Journal of applied physiology.