Measuring reaction kinetics in a lab-on-a-chip by microcoil NMR.

A microfluidic chip with an integrated planar microcoil was developed for Nuclear Magnetic Resonance (NMR) spectroscopy on samples with volumes of less than a microliter. Real-time monitoring of imine formation from benzaldehyde and aniline in the microreactor chip by NMR was demonstrated. The reaction times in the chip can be set from 30 min down to ca. 2 s, the latter being the mixing time in the microfluidic chip. Design rules will be described to optimize the microreactor and detection coil in order to deal with the inherent sensitivity of NMR and to minimize magnetic field inhomogeneities and obtain sufficient spectral resolution.

[1]  A P M Kentgens,et al.  Towards nuclear magnetic resonance micro-spectroscopy and micro-imaging. , 2004, The Analyst.

[2]  Takehiko Kitamori,et al.  A Microfluidic Device for Conducting Gas-Liquid-Solid Hydrogenation Reactions , 2004, Science.

[3]  Charles Massin Microfabricated planar coils in nuclear magnetic resonance , 2004 .

[4]  Luisa Ciobanu,et al.  Measuring reaction kinetics by using multiple microcoil NMR spectroscopy. , 2003, Angewandte Chemie.

[5]  Eun Kyu Lee,et al.  Applicability of laser-induced Raman microscopy forin situ monitoring of imine formation in a glass microfluidic chip , 2003 .

[6]  N F de Rooij,et al.  Planar microcoil-based microfluidic NMR probes. , 2003, Journal of magnetic resonance.

[7]  Scott D. Collins,et al.  A Micromachined Double-Tuned NMR Microprobe , 2003 .

[8]  D. Raftery,et al.  High-throughput nuclear magnetic resonance analysis using a multiple coil flow probe. , 2003, Analytical chemistry.

[9]  J. Sweedler,et al.  Hyphenation of capillary separations with nuclear magnetic resonance spectroscopy. , 2003, Journal of chromatography. A.

[10]  Jonathan V Sweedler,et al.  Micromixer-based time-resolved NMR: applications to ubiquitin protein conformation. , 2003, Analytical chemistry.

[11]  Volker Hessel,et al.  Chemical micro process engineering , 2003 .

[12]  J. Choo,et al.  Reaction monitoring of imine synthesis using Raman spectroscopy , 2003 .

[13]  Michael Curt Elwenspoek,et al.  Reduction of sidewall inclination and blast lag of powder blasted channels , 2002 .

[14]  A. van den Berg,et al.  Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry. , 2002, Analytical chemistry.

[15]  P.-A. Besse,et al.  High-Q factor RF planar microcoils for micro-scale NMR spectroscopy , 2002 .

[16]  Stephen J. Haswell,et al.  Chemical and biochemical microreactors , 2000 .

[17]  Richard L. Magin,et al.  Integrating microfabricated fluidic systems and NMR spectroscopy , 2000, IEEE Transactions on Biomedical Engineering.

[18]  Andrew G. Webb,et al.  Radiofrequency microcoils in magnetic resonance , 1997 .

[19]  Richard L. Magin,et al.  High-Resolution Microcoil 1H-NMR for Mass-Limited, Nanoliter-Volume Samples , 1995, Science.

[20]  N. Hirota,et al.  TRANSLATIONAL DIFFUSION OF TRANSIENT RADICALS CREATED BY THE PHOTOINDUCED HYDROGEN ABSTRACTION REACTION IN SOLUTION : ANOMALOUS SIZE DEPENDENCE IN THE RADICAL DIFFUSION , 1995 .

[21]  A. Derome,et al.  Modern Nmr Techniques for Chemistry Research , 1987 .

[22]  Gertrud Beggerow,et al.  Numerical data and functional relationships in science and technology , 1976 .

[23]  R. Bechmann,et al.  Numerical data and functional relationships in science and technology , 1969 .