Laboratory study of selected personal inhalable aerosol samplers.

Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers have been studied in two laboratory wind tunnels using polydisperse glass-beads' test aerosol. Samplers tested were IOM sampler (UK), two versions of CIP 10-I sampler, v1 and v2 (F), 37-mm closed face cassette sampler (USA), 37-mm cassette fitted up with an ACCU-CAP insert (USA), and Button sampler (USA). Particle size-dependent sampling efficiencies were measured in a horizontal wind tunnel under a 1 m s(-1) wind velocity and in a vertical tunnel under calm air, using a specific method with Coulter(R) counter particle size number distribution determinations. Compared with CEN-ISO-ACGIH sampling criteria for inhalable dust, the experimental results show fairly high sampling efficiency for the IOM and CIP 10-I v2 samplers and slightly lower efficiencies for the Button and CIP 10-I v1 samplers. The closed face cassette (4-mm orifice) produced the poorest performances of all the tested samplers. This can be improved by using the ACCU-CAP internal capsule, which prevents inner wall losses inside the cassette. Significant differences between moving air and calm air sampling efficiency were observed for all the studied samplers.

[1]  James H Vincent,et al.  Experimental methods to determine inhalability and personal sampler performance for aerosols in ultra-low windspeed environments. , 2008, Journal of environmental monitoring : JEM.

[2]  Wolfgang Koch,et al.  Design and Performance of a New Personal Aerosol Monitor , 1999 .

[3]  P. Görner,et al.  High efficiency CIP 10-I personal inhalable aerosol sampler , 2009 .

[4]  J H Vincent,et al.  A new personal sampler for airborne total dust in workplaces. , 1986, The Annals of occupational hygiene.

[5]  Kevin Ashley,et al.  Analytical Performance Criteria , 2007 .

[6]  M. Demange,et al.  AEROSOL EVALUATION DIFFICULTIES DUE TO PARTICLE DEPOSITION ON FILTER HOLDER INNER WALLS , 1990 .

[7]  Brian G. Miller,et al.  Aerosol inhalability at higher windspeeds , 1990 .

[8]  S N Li,et al.  Evaluation of six inhalable aerosol samplers. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[9]  C. N. Davies,et al.  The entry of aerosols into sampling tubes and heads , 1968 .

[10]  J. Agarwal,et al.  A criterion for accurate aerosol sampling in calm air. , 1980, American Industrial Hygiene Association journal.

[11]  Martin Harper,et al.  An evaluation of total and inhalable samplers for the collection of wood dust in three wood products industries. , 2002, Journal of environmental monitoring : JEM.

[12]  K Willeke,et al.  Performance characteristics of the button personal inhalable aerosol sampler. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[13]  S. Paik,et al.  The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies. , 2004, The Annals of occupational hygiene.

[14]  W. Tabakoff,et al.  Airflow and Particle Velocities Near a Personal Aerosol Sampler with a Curved, Porous Aerosol Sampling Surface , 1998 .

[15]  R. W. Lines,et al.  The Electrical Sensing Zone Method (The Coulter Principle) , 1992 .

[16]  Richard Wrobel,et al.  A new experimental wind tunnel facility for aerosol sampling investigations , 1997 .

[17]  M A Puskar,et al.  Internal wall losses of pharmaceutical dusts during closed-face, 37-mm polystyrene cassette sampling. , 1991, American Industrial Hygiene Association journal.

[18]  T. Allen Particle Size Measurement , 1965, Nature.

[19]  Martin Harper,et al.  Comparison of wood-dust aerosol size-distributions collected by air samplers. , 2004, Journal of environmental monitoring : JEM.

[20]  P. Görner,et al.  Personal thoracic CIP10-T sampler and its static version CATHIA-T. , 1998, The Annals of occupational hygiene.

[21]  Olivier Witschger,et al.  Aerosol sampling by annular aspiration slots. , 2008, Journal of environmental monitoring : JEM.

[22]  Paul A. Baron,et al.  Investigation of Filter Bypass Leakage and a Test for Aerosol Sampling Cassettes , 2002 .

[23]  James H Vincent,et al.  Health-related aerosol measurement: a review of existing sampling criteria and proposals for new ones. , 2005, Journal of environmental monitoring : JEM.

[24]  Klaus Willeke,et al.  Evaluation of personal aerosol samplers challenged with large particles , 2001 .

[25]  James H Vincent Testing personal inhalable aerosol samplers: a suggested improved protocol based on new scientific knowledge. , 2006, Journal of environmental monitoring : JEM.

[26]  S A Grinshpun,et al.  Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source. , 2004, The Annals of occupational hygiene.

[27]  D. Mokadam,et al.  Field Performance of the RespiConTMfor Size-Selective Sampling of Industrial Wood Processing Dust , 2005, Journal of occupational and environmental hygiene.

[28]  K. Willeke,et al.  A general equation for aerosol aspiration by thin-walled sampling probes in calm and moving air , 1993 .

[29]  G. Lachapelle,et al.  Behaviour of the IOM aerosol sampler as a function of external wind velocity and orientation , 1998 .

[30]  Akademii︠a︡ medit︠s︡inskikh nauk Sssr Journal of physics , 1939 .

[31]  K. Willeke,et al.  MEASUREMENT OF THE SAMPLING EFFICIENCY OF PERSONAL INHALABLE AEROSOL SAMPLERS USING A SIMPLIFIED PROTOCOL , 2000 .

[32]  James H. Vincent,et al.  Inhalability for aerosols at ultra-low windspeeds , 2009 .

[33]  S C Soderholm,et al.  Aerosol sampling efficiency of 37 mm filter cassettes. , 1986, American Industrial Hygiene Association journal.

[34]  Andrew D. Maynard,et al.  A Survey of Wind Speeds in Indoor Workplaces , 1998 .

[35]  Irma Welling,et al.  Occupational exposure to inhalable wood dust in the member states of the European Union. , 2006, The Annals of occupational hygiene.

[36]  K. Willeke,et al.  Simplified method for testing personal inhalable aerosol samplers , 1998 .

[37]  J. Guichard AEROSOL GENERATION USING FLUIDIZED BEDS , 1976 .

[38]  Richard Wrobel,et al.  Personal thoracic CIP10-T sampler and its static version Cathia-T , 1998 .

[39]  W. Koch,et al.  Small-scale aerosol sampler testing systems , 2000 .

[40]  W. Hinds,et al.  Comparison of a Simplified and Full-Size Mannequin for the Evaluation of Inhalable Sampler Performance , 2001 .

[41]  L. C. Kenny,et al.  A technique for assessing size-selective dust samplers using the APS and polydisperse test aerosols , 1991 .

[42]  S. Grinshpun,et al.  Sampling Errors in Cylindrical Nozzles , 1990 .

[43]  Wolfgang Koch,et al.  Evaluation of the respicon as a personal inhalable sampler in industrial environments. , 2002, Journal of environmental monitoring : JEM.

[44]  P. Görner,et al.  Site comparison of selected aerosol samplers in the wood industry. , 2010, The Annals of occupational hygiene.

[45]  Richard Wrobel,et al.  Experimental method to determine the efficiency of aerosolsamplers using the Coulter counter , 2000 .

[46]  Anders Gudmundsson,et al.  WORKPLACE VALIDATION OF A LABORATORY EVALUATION TEST OF SAMPLERS FOR INHALABLE AND “TOTAL” DUST , 2000 .

[47]  J. Vincent,et al.  Towards a general semi-empirical model for the aspiration efficiencies of aerosol samplers in perfectly calm air , 2004 .

[48]  James S Brown Particle Inhalability at Low Wind Speeds , 2005, Inhalation toxicology.

[49]  Andrew D. Maynard,et al.  Aerosol inhalability in low air movement environments , 1999 .

[50]  A. Maynard,et al.  A survey of wind speeds in indoor workplaces. , 1998, The Annals of occupational hygiene.

[51]  Martin Harper,et al.  The Need for an International Sampling Convention for Inhalable Dust in Calm Air , 2006 .

[52]  Richard Wrobel,et al.  Field comparison of 37-mm closed-face cassettes and IOM samplers. , 2002, Applied occupational and environmental hygiene.

[53]  Towards a new method for experimental determination of aerosol sampler aspiration efficiency in small wind tunnels , 1998 .

[54]  Klaus Willeke,et al.  New aerosol sampler with low wind sensitivity and good filter collection uniformity , 1995 .

[55]  J H Vincent,et al.  Entry characteristics of practical workplace aerosol samplers in relation to the ISO recommendations. , 1990, The Annals of occupational hygiene.

[56]  T. Ogden,et al.  Wind effects on personal dust samplers , 1987 .

[57]  L. Noro,et al.  Institute of Occupational Health , 1966, Suomen laakarilehti. Finlands lakartidning.

[58]  Jean-Francois Fabries,et al.  A NEW INDIVIDUAL RESPIRABLE DUST SAMPLER: THE CIP 10 , 1988 .

[59]  Andrew D. Maynard,et al.  The sampling efficiency of personal inhalable aerosol samplers in low air movement environments , 1999 .

[60]  缪巍 THESE de DOCTORAT de l’UNIVERSITE PARIS VI , 2010 .

[61]  H Kromhout,et al.  A collaborative European study of personal inhalable aerosol sampler performance. , 1997, The Annals of occupational hygiene.

[62]  David L. Bartley,et al.  Inhalable Aerosol Samplers , 1998 .

[63]  G. Gee,et al.  Particle-size Analysis , 2018, SSSA Book Series.