Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device

BackgroundThe aim of this study was to quantify the effect of the new Low-profile Visualized Intraluminal Support (LVIS®D) device and the difference of fluid diverting effect compared with the Pipeline device and the Enterprise stent using computational fluid dynamics (CFD).MethodsIn this research, we simulated three aneurysms constructed from 3D digital subtraction angiography (DSA). The Enterprise, LVIS and the Pipeline device were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. Computational fluid dynamics analysis was performed to compare the hemodynamic differences such as WSS, Velocity and Pressure among these stents.ResultsControl referred to the unstented model, the percentage of hemodynamic changes were all compared to Control. A single LVIS stent caused more wall shear stress reduction than double Enterprise stents (39.96 vs. 30.51 %) and velocity (23.13 vs. 18.64 %). Significant reduction in wall shear stress (63.88 %) and velocity (46.05 %) was observed in the double-LVIS stents. A single Pipeline showed less reduction in WSS (51.08 %) and velocity (37.87 %) compared with double-LVIS stent. The double-Pipeline stents resulted in the most reduction in WSS (72.37 %) and velocity (54.26 %). Moreover, the pressure increased with minuscule extent after stenting, compared with the unstented model.ConclusionsThis is the first study analyzing flow modifications associated with LVIS stents. We found that the LVIS stent has certain hemodynamic effects on cerebral aneurysms: a single LVIS stent caused more flow reductions than the double-Enterprise stent but less than a Pipeline device. Nevertheless, the double-LVIS stent resulted in a better flow diverting effect than a Pipeline device.

[1]  C. Putman,et al.  Flow–area relationship in internal carotid and vertebral arteries , 2008, Physiological measurement.

[2]  M. Bendszus,et al.  The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy , 2014, Neuroradiology.

[3]  A. Turk,et al.  Low-profile visible intraluminal support device: immediate outcome of the first three US cases , 2012, Journal of NeuroInterventional Surgery.

[4]  David H. Frakes,et al.  Flow diverter effect on cerebral aneurysm hemodynamics: an in vitro comparison of telescoping stents and the Pipeline , 2013, Neuroradiology.

[5]  Hervé Delingette,et al.  General Object Reconstruction Based on Simplex Meshes , 1999, International Journal of Computer Vision.

[6]  C. Sohn,et al.  Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS™) device , 2014, Neuroradiology.

[7]  E. Ring SUMMARY OF SAFETY AND PROBABLE BENEFIT , 2003 .

[8]  Kyehan Rhee,et al.  CFD modeling of blood flow following coil embolization of aneurysms. , 2004, Medical engineering & physics.

[9]  R. Rosenwasser,et al.  ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILS , 2004, Neurosurgery.

[10]  J. Palmaz,et al.  Intravascular stents: tissue-stent interactions and design considerations. , 1993, AJR. American journal of roentgenology.

[11]  Fumihito Arai,et al.  The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters , 2012, Asian journal of neurosurgery.

[12]  A. Aliseda,et al.  Cerebral Aneurysms Treated with Flow-Diverting Stents: Computational Models with Intravascular Blood Flow Measurements , 2014, American Journal of Neuroradiology.

[13]  B. Frémont,et al.  SUMMARY OF SAFETY AND EFFECTIVENESS DATA , 2002 .

[14]  T. Terada,et al.  Hemodynamic Effects of Stent Struts versus Straightening of Vessels in Stent-Assisted Coil Embolization for Sidewall Cerebral Aneurysms , 2014, PloS one.

[15]  Gábor Janiga,et al.  Impact of stents and flow diverters on hemodynamics in idealized aneurysm models. , 2011, Journal of biomechanical engineering.

[16]  J. Xiang,et al.  Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization , 2015, Journal of NeuroInterventional Surgery.

[17]  J. Xiang,et al.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents. , 2010, World neurosurgery.

[18]  Jianping Xiang,et al.  High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms. , 2015, Journal of neurosurgery.

[19]  Sebastian Fischer,et al.  Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections , 2011, Neuroradiology.

[20]  I. Saatci,et al.  Stent-Assisted Coiling in Endovascular Treatment of 500 Consecutive Cerebral Aneurysms with Long-Term Follow-Up , 2013, American Journal of Neuroradiology.

[21]  E. Balaras,et al.  Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms. , 2007, Journal of biomechanical engineering.

[22]  A. Weber,et al.  Low-profile Visualized Intraluminal Support device (LVIS Jr) as a novel tool in the treatment of wide-necked intracranial aneurysms: initial experience in 32 cases , 2014, Journal of NeuroInterventional Surgery.

[23]  K. Safranow,et al.  The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registry , 2014, Journal of NeuroInterventional Surgery.

[24]  L. Ge,et al.  Numerical Modeling of the Flow in Intracranial Aneurysms: Prediction of Regions Prone to Thrombus Formation , 2008, Annals of Biomedical Engineering.

[25]  R. Löhner,et al.  Fast numerical solutions of patient‐specific blood flows in 3D arterial systems , 2010, International journal for numerical methods in biomedical engineering.

[26]  Hui Meng,et al.  Comparison of Two Stents in Modifying Cerebral Aneurysm Hemodynamics , 2008, Annals of Biomedical Engineering.

[27]  A. Wakhloo,et al.  Self-expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response. , 1995, AJNR. American journal of neuroradiology.

[28]  Guanghong Ding,et al.  High Shear Stress and Flow Velocity in Partially Occluded Aneurysms Prone to Recanalization , 2011, Stroke.

[29]  Hai-yun Li,et al.  Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: a patient-specific computational fluid dynamic simulation study. , 2012, Journal of neurosurgery.

[30]  N. Stergiopulos,et al.  Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral Aneurysms , 2011, Annals of Biomedical Engineering.

[31]  L. Solymosi,et al.  A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms , 2007, Neuroradiology.

[32]  Zhijie Wang,et al.  Complex Hemodynamics at the Apex of an Arterial Bifurcation Induces Vascular Remodeling Resembling Cerebral Aneurysm Initiation , 2007, Stroke.

[33]  Alejandro F. Frangi,et al.  Fast virtual deployment of self-expandable stents: Method and in vitro evaluation for intracranial aneurysmal stenting , 2012, Medical Image Anal..

[34]  J. Mocco,et al.  Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. , 2009, Journal of neurosurgery.

[35]  Philippe Bijlenga,et al.  Intracranial aneurysm stenting: Follow‐up with MR angiography , 2006, Journal of magnetic resonance imaging : JMRI.

[36]  D. Fiorella,et al.  Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-up , 2005, Neurosurgery.

[37]  Alejandro F. Frangi,et al.  Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics , 2011, Interface Focus.

[38]  Alexa N Richie,et al.  Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report , 2013, Journal of NeuroInterventional Surgery.

[39]  David F. Kallmes,et al.  Endovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis , 2013, Stroke.

[40]  Nikhil Paliwal,et al.  Fast Virtual Stenting With Vessel-Specific Initialization and Collision Detection , 2014 .