Monolithic Multiband CMUTs for Photoacoustic Computed Tomography With In Vivo Biological Tissue Imaging

Among the biomedical imaging modalities, photoacoustic computed tomography (PACT) was one of the emerging hybrid techniques in recent years. In designing the PACT imaging system, a finite-bandwidth transducer is one of the limited factors for the overall performance. As the target size is inversely proportional to the dominant frequency components of the generated photoacoustic (PA) signal, a broad bandwidth transducer is desired for different scales’ imaging. In this paper, a monolithic multiband capacitive micromachined ultrasonic transducer (CMUT) array was designed and fabricated for the reception of the wideband PA signals so as to provide high-resolution images with high-frequency CMUT arrays and present the high signal-to-noise-ratio major structure with low-frequency CMUT arrays. To demonstrate its performance, a phantom experiment was conducted to show and evaluate the various qualities of multiresolution images. In addition, an in vivo mouse model experiment was also carried out for revealing the multiscale PA imaging capability with the multiband CMUTs on biological tissues. From the obtained results, the images from different CMUT arrays could show the structures of the mouse brain in different scales. In addition, the images from the high-frequency CMUT arrays were able to reveal the major blood vasculatures, whereas the images from low-frequency CMUT arrays showed the gross macroscopic anatomy of the brain with higher contrast.

[1]  Qifa Zhou,et al.  All-optical photoacoustic microscopy based on plasmonic detection of broadband ultrasound , 2015 .

[2]  Paul C. Beard,et al.  Optical detection system for biomedical photoacoustic imaging , 2000, BiOS.

[3]  Zhen Yuan,et al.  Photoacoustic Tomography Imaging of the Adult Zebrafish by Using Unfocused and Focused High-Frequency Ultrasound Transducers , 2016 .

[4]  Quing Zhu,et al.  Real-time photoacoustic tomography of cortical hemodynamics in small animals. , 2010, Journal of biomedical optics.

[5]  Pai-Chi Li,et al.  A photoacoustic imager with light illumination through an infrared-transparent silicon CMUT array , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  A. Bouakaz,et al.  Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Hans J. Hedrich,et al.  The laboratory mouse , 2004 .

[8]  L. Miranda,et al.  Investigation of poling field effects on PVDF pyroelectric detectors: Photoacoustic thermal diffusivity measurements , 1990 .

[9]  Quing Zhu,et al.  A real-time photoacoustic tomography system for small animals. , 2009, Optics express.

[10]  Roger J. Zemp,et al.  Multifrequency Interlaced CMUTs for Photoacoustic Imaging , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[11]  Charles H. Sherman,et al.  Transducers and Arrays for Underwater Sound , 2008 .

[12]  D. Vray,et al.  Dual Frequency Band Annular Probe for Volumetric Pulse-echo Optoacoustic Imaging , 2015 .

[13]  Butrus T. Khuri-Yakub,et al.  Deep Tissue Photoacoustic Imaging Using a Miniaturized 2-D Capacitive Micromachined Ultrasonic Transducer Array , 2012, IEEE Transactions on Biomedical Engineering.

[14]  Da Xing,et al.  Characterization of lipid-rich aortic plaques by intravascular photoacoustic tomography: ex vivo and in vivo validation in a rabbit atherosclerosis model with histologic correlation. , 2014, Journal of the American College of Cardiology.

[15]  Aya Kamaya,et al.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Lihong V. Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography. , 2005 .

[17]  Xuefeng Zhuang,et al.  Capacitive micromachined ultrasonic transducers with through-wafer interconnects , 2008 .

[18]  Hongkai Zhao,et al.  An Efficient Neumann Series-Based Algorithm for Thermoacoustic and Photoacoustic Tomography with Variable Sound Speed , 2011, SIAM J. Imaging Sci..

[19]  S. Gambhir,et al.  1E-3 Tomographic Photoacoustic Imaging Using Capacitive Micromachined Ultrasonic Transducer (CMUT) Technology , 2006, 2006 IEEE Ultrasonics Symposium.

[20]  O. Oralkan,et al.  Photoacoustic imaging using a two-dimensional CMUT array , 2005, IEEE Ultrasonics Symposium, 2005..

[21]  Alexander Sampaleanu,et al.  Top orthogonal to bottom electrode (TOBE) 2-D CMUT arrays for 3-D photoacoustic imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[22]  Huabei Jiang,et al.  Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy , 2012, Biomedical optics express.

[23]  S L Jacques,et al.  Optical properties of intralipid: A phantom medium for light propagation studies , 1992, Lasers in surgery and medicine.

[24]  Quing Zhu,et al.  Three-dimensional photoacoustic tomography based on the focal-line concept. , 2011, Journal of biomedical optics.

[25]  M. Karaman,et al.  Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  B. Khuri-Yakub,et al.  Surface micromachined capacitive ultrasonic transducers , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  Paulina S. Kuo,et al.  Capacitive micromachined ultrasonic transducers (CMUTs) for photoacoustic imaging , 2006, SPIE BiOS.

[28]  Jingkuang Chen,et al.  A Miniature Capacitive Micromachined Ultrasonic Transducer Array for Minimally Invasive Photoacoustic Imaging , 2010, Journal of Microelectromechanical Systems.

[29]  Sigrid Berg,et al.  Capacitive micromachined ultrasonic transducers : Acoustic challenges and proposed solutions , 2012 .

[30]  Geng Ku,et al.  Multiple-bandwidth photoacoustic tomography. , 2004, Physics in medicine and biology.

[31]  Cheng Sun,et al.  Optical Detection of Ultrasound in Photoacoustic Imaging , 2017, IEEE Transactions on Biomedical Engineering.

[32]  Zhen Yuan,et al.  Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography , 2016, BioMed research international.

[33]  Kwan Kyu Park,et al.  Acoustic lens for capacitive micromachined ultrasonic transducers , 2014 .

[34]  Huabei Jiang,et al.  Quantitative photoacoustic tomography , 2009, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[35]  Kin Fong Lei,et al.  Development of a multi-band photoacoustic tomography imaging system based on a capacitive micromachined ultrasonic transducer array. , 2017, Applied optics.

[36]  Sanjiv S. Gambhir,et al.  3-D Deep penetration photoacoustic imaging with a 2-D CMUT array , 2010, 2010 IEEE International Ultrasonics Symposium.

[37]  Tsuyoshi Shiina,et al.  Photoacoustic mammography capable of simultaneously acquiring photoacoustic and ultrasound images , 2016, Journal of biomedical optics.

[38]  Lihong V Wang,et al.  Photoacoustic tomography and sensing in biomedicine , 2009, Physics in medicine and biology.

[39]  Minghua Xu,et al.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[40]  Navalgund Rao,et al.  Basics and Clinical Applications of Photoacoustic Imaging , 2009 .

[41]  John Mould,et al.  Silicon substrate ringing in microfabricated ultrasonic transducers , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[42]  O. Warshavski,et al.  Experimental evaluation of cMUT and PZT transducers in receive only mode for photoacoustic imaging , 2016, SPIE BiOS.

[43]  Roman Gr. Maev Acoustic Microscopy: Fundamentals and Applications , 2008 .

[44]  B.T. Khuri-Yakub,et al.  Finite-element analysis of capacitive micromachined ultrasonic transducers , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[45]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducers: fabrication technology , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[46]  Xu Xiao Photoacoustic imaging in biomedicine , 2008 .

[47]  M. Haltmeier,et al.  Exact and approximative imaging methods for photoacoustic tomography using an arbitrary detection surface. , 2007, Physical review. E, Statistical, nonlinear, and soft matter physics.

[48]  A. Oraevsky,et al.  Detection of ultrawide-band ultrasound pulses in optoacoustic tomography , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.