Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis.

Prosthetic joints appear to show a strong relationship between the type of relative motion and wear, requiring careful consideration in the design of wear simulators. This relationship was studied with a 12-station pin-on-disk device, specifically adapted for the wear simulation of prosthetic hip joints. Each station had a unique motion, characterized by the so-called slide track, the track of the pin on the disk. The slide track shapes included 10 ellipses, their aspect ratio (AR) varying from 1.1 to 11.0, and a circle and a straight line as extreme cases. Hence for the first time in hip wear simulation, the motion was systematically varied over a wide range. Conventional UHMWPE pins were tested against polished CoCr disks in diluted calf serum three times for 3 million cycles. Below the AR value of 5.5, the polyethylene wear factor and wear mechanisms agreed with clinical observations. Above this value, the wear factor decreased to unrealistically low values, and the wear surface topography differed from that of retrieved acetabular cups. The wear particles, however, were similar to those isolated from periprosthetic tissues, irrespective of the AR value. In conclusion, it is recommended that the AR value be kept well below the critical point of 5.5.

[1]  C. Bragdon,et al.  The Importance of Multidirectional Motion on the Wear of Polyethylene , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  V. Saikko,et al.  A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. , 1998, Journal of biomedical materials research.

[3]  Olof Calonius,et al.  Force track analysis of contemporary hip simulators. , 2003, Journal of biomechanics.

[4]  J H Dumbleton,et al.  Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement Prostheses , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  Olof Calonius,et al.  Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. , 2002, Journal of biomechanics.

[6]  Olof Calonius,et al.  Slide track analysis of eight contemporary hip simulator designs. , 2002, Journal of biomechanics.

[7]  Olof Calonius,et al.  Tribology of Prosthetic Joints - Validation of Wear Simulation Methods , 2002 .

[8]  C. M. Agrawal,et al.  Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties. , 2002, Journal of biomedical materials research.

[9]  J. Fisher,et al.  Biological reactions to wear debris in total joint replacement , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  R Baker,et al.  The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  V. Saikko,et al.  Type of motion and lubricant in wear simulation of polyethylene acetabular cup , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  Vesa Saikko,et al.  Effect of Lubricant Protein Concentration on the Wear of Ultra-High Molecular Weight Polyethylene Sliding Against a CoCr Counterface , 2003 .

[13]  S. Jani,et al.  Do current wear particle isolation procedures underestimate the number of particles generated by prosthetic bearing components , 2001 .

[14]  A Unsworth,et al.  Wear in Retrieved Charnley Acetabular Sockets , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  V. Saikko,et al.  Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. , 2001, Journal of biomedical materials research.