Evaluation of myocardial defect detection between parallel-hole and fan-beam SPECT using the Hotelling trace

The objective of this study was to implement the Hotelling trace (HT) to evaluate the potential increase in defect detection in myocardial SPECT using high-resolution fan-beam (HRF) versus parallel-hole (HRP) collimation and compare results to a previously reported human observer study (G.K. Gregoriou et al., ibid., vol. 42, p. 1267-75, 1995). Projection data from the 3D MCAT torso phantom were simulated including the effects of attenuation, collimator-detector response blurring and scatter. Poisson noise fluctuations were then simulated. The HRP and HRF collimators had the same spatial resolution at 20 cm. The total counts in the projection data sets were proportional to the detection efficiencies of the collimators and on the order of that found in clinical Tc-99m studies. In six left-ventricular defect locations, the HT found for HRF was superior to that for HRP collimation. For HRF collimation, the HT was calculated for reconstructed images using 64/spl times/64, 128/spl times/128 and 192/spl times/192 grid sizes. The results demonstrate substantial improvement in myocardial defect detection when the grid size was increased from 64/spl times/64 to 128/spl times/128 and slight improvement from 128/spl times/128 to 192/spl times/192. Also, the performance of the Hotelling observer in terms of the HT at the different grid sizes correlates at better than 0.95 to that found in human observers in a previously reported observer experiment and ROC study.

[1]  H H Barrett,et al.  Objective assessment of image quality: effects of quantum noise and object variability. , 1990, Journal of the Optical Society of America. A, Optics and image science.

[2]  Craig K. Abbey,et al.  Practical issues and methodology in assessment of image quality using model observers , 1997, Medical Imaging.

[3]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[4]  Harrison H. Barrett,et al.  Hotelling trace criterion as a figure of merit for the optimization of imaging systems , 1986 .

[5]  Kyle J. Myers,et al.  Model observers for assessment of image quality , 1993 .

[6]  H. Barrett,et al.  Effect of noise correlation on detectability of disk signals in medical imaging. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[7]  H H Barrett,et al.  Hotelling trace criterion and its correlation with human-observer performance. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[8]  G. Gullberg,et al.  Evaluation of the effect of reconstructed image pixel size on defect detectability in Tl-201 fan-beam SPECT by an observer performance study , 1995 .

[9]  Keinosuke Fukunaga,et al.  Effects of Sample Size in Classifier Design , 1989, IEEE Trans. Pattern Anal. Mach. Intell..

[10]  Berkman Sahiner,et al.  Finite-sample effects and resampling plans: applications to linear classifiers in computer-aided diagnosis , 1997, Medical Imaging.

[11]  Jannick P. Rolland,et al.  Factors influencing lesion detection in medical imaging. , 1990 .

[12]  H. Hotelling The Generalization of Student’s Ratio , 1931 .

[13]  H H Barrett,et al.  Addition of a channel mechanism to the ideal-observer model. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[14]  Robin N. Strickland,et al.  Channelized detection filters for detecting tumors in nuclear medical images , 1997, Medical Imaging.

[15]  R. F. Wagner,et al.  Aperture optimization for emission imaging: effect of a spatially varying background. , 1990, Journal of the Optical Society of America. A, Optics and image science.