초고층 복층형 아파트의 결로발생 평가 및 대책

The purpose of this study is to analyse and investigate the condensation at two-storied high-rise apartment building. Condensation occurs when the air temperature is decreased under the dew point. It makes problems for healthy trouble, moldy wall, a deformation of the building construction, and etc. In this study, we analyse and take steps to apply the numerical method for glass wall conduction, to calculate the amount of infiltration air, and to simulate computation ally for flow of indoor air. In our model condensation is not caused by from the wall conduction between indoor and outdoor, but by air infiltrating temperature, supply air quantity and indoor air flow. We can prevent the condensation through the air quantity of supply air, change of supply air direction, and installation of convector on the bottom floor under the windows.