Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison

Abstract Theoretical analysis and comparison of the sensitivity of surface plasmon resonance (SPR) sensors using diffraction at gratings and attenuated total reflection (ATR) in prism couplers for two detection methods-resonant angle interrogation and resonant wavelength interrogation is presented. Analytical expressions for sensitivity of these SPR sensors are derived and the influence of the major design parameters of the sensing structures on the sensor sensitivity is discussed. The analysis shows that grating-based SPR sensors using wavelength interrogation are much less sensitive then their prism coupler-based counterparts. In the angular interrogation mode, the sensitivity of SPR sensors using diffraction gratings depends on the diffraction order and does not differ much from that of SPR sensors based on prism couplers.

[1]  Petr I. Nikitin,et al.  A multi-purpose sensor based on surface plasmon polariton resonance in a Schottky structure , 1994 .

[2]  J. Homola On the sensitivity of surface plasmon resonance sensors with spectral interrogation , 1997 .

[3]  R. Georgiadis,et al.  Two-color approach for determination of thickness and dielectric constant of thin films using surface plasmon resonance spectroscopy , 1996 .

[4]  D C Cullen,et al.  Detection of immuno-complex formation via surface plasmon resonance on gold-coated diffraction gratings. , 1987, Biosensors.

[5]  Eric M. Yeatman,et al.  Resolution and sensitivity in surface plasmon microscopy and sensing , 1996 .

[6]  H. E. de Bruijn,et al.  Choice of metal and wavelength for surface-plasmon resonance sensors: some considerations. , 1992, Applied optics.

[7]  J. D. Swalen,et al.  Surface plasmon spectroscopy of organic monolayer assemblies , 1978 .

[8]  Thomas K. Gaylord,et al.  Rigorous coupled-wave analysis of metallic surface-relief gratings , 1986 .

[9]  H. Raether Surface Plasmons on Smooth and Rough Surfaces and on Gratings , 1988 .

[10]  Jan Greve,et al.  Surface plasmon resonance immunosensors: sensitivity considerations , 1988 .

[11]  B. Liedberg,et al.  Principles of biosensing with an extended coupling matrix and surface plasmon resonance , 1993 .

[12]  J. R. Sambles,et al.  A surface-plasmon-based optical sensor using acousto-optics , 1995 .

[13]  D. Furlong,et al.  Surface plasmon resonance studies of immunoreactions utilizing disposable diffraction gratings. , 1996, Biosensors & bioelectronics.

[14]  Deepak Uttamchandani,et al.  Optical chemical sensing employing surface plasmon resonance , 1988 .

[15]  O. Parriaux,et al.  Plasmon wave versus dielectric waveguiding for surface wave sensing , 1990 .

[16]  G Gauglitz,et al.  Characterization of biomembranes by spectral ellipsometry, surface plasmon resonance and interferometry with regard to biosensor application. , 1994, Biosensors & bioelectronics.