Development and validation of patient-specific finite element models of the hemipelvis generated from a sparse CT data set.

To produce a patient-specific finite element (FE) model of a bone such as the pelvis, a complete computer tomographic (CT) or magnetic resonance imaging (MRI) geometric data set is desirable. However, most patient data are limited to a specific region of interest such as the acetabulum. We have overcome this problem by providing a hybrid method that is capable of generating accurate FE models from sparse patient data sets. In this paper, we have validated our technique with mechanical experiments. Three cadaveric embalmed pelves were strain gauged and used in mechanical experiments. FE models were generated from the CT scans of the pelves. Material properties for cancellous bone were obtained from the CT scans and assigned to the FE mesh using a spatially varying field embedded inside the mesh while other materials used in the model were obtained from the literature. Although our FE meshes have large elements, the spatially varying field allowed them to have location dependent inhomogeneous material properties. For each pelvis, five different FE meshes with a varying number of patient CT slices (8-12) were generated to determine how many patient CT slices are needed for good accuracy. All five mesh types showed good agreement between the model and experimental strains. Meshes generated with incomplete data sets showed very similar stress distributions to those obtained from the FE mesh generated with complete data sets. Our modeling approach provides an important step in advancing the application of FE models from the research environment to the clinical setting.

[1]  P Zioupos,et al.  Effect of formaldehyde fixation on some mechanical properties of bovine bone. , 1995, Biomaterials.

[2]  C. Chadwick,et al.  The use of the Internet by orthopaedic outpatients. , 2001, The Journal of bone and joint surgery. British volume.

[3]  N. Palastanga,et al.  Anatomy and Human Movement: Structure and Function , 1989 .

[4]  B. Augereau,et al.  Experimental study of periacetabular deformations before and after implantation of hip prostheses. , 1996, Journal of biomechanics.

[5]  Peter J Hunter,et al.  The use of sparse CT datasets for auto-generating accurate FE models of the femur and pelvis. , 2007, Journal of biomechanics.

[6]  F. G. Evans,et al.  The mechanical properties of bone. , 1969, Artificial limbs.

[7]  J. Lotz,et al.  Impact biomechanics and pelvic deformation during insertion of press-fit acetabular cups. , 2002, The Journal of arthroplasty.

[8]  R. Huiskes,et al.  Load transfer across the pelvic bone. , 1995, Journal of biomechanics.

[9]  P J Hunter,et al.  An anatomically based patient-specific finite element model of patella articulation: towards a diagnostic tool , 2005, Biomechanics and modeling in mechanobiology.

[10]  T D Brown,et al.  A contact-coupled finite element analysis of the natural adult hip. , 1984, Journal of biomechanics.

[11]  Marco Viceconti,et al.  An improved method for the automatic mapping of computed tomography numbers onto finite element models. , 2004, Medical engineering & physics.

[12]  J. Weiss,et al.  Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. , 2005, Journal of biomechanical engineering.

[13]  J B Finlay,et al.  Pelvic stresses in vitro--I. Malsizing of endoprostheses. , 1986, Journal of biomechanics.

[14]  H B Skinner,et al.  Correlation of Computed Finite Element Stresses to Bone Density After Remodeling Around Cementless Femoral Implants , 1994, Clinical orthopaedics and related research.

[15]  R I Price,et al.  Formalin fixation effects on vertebral bone density and failure mechanics: an in-vitro study of human and sheep vertebrae. , 1994, Clinical biomechanics.

[16]  J. Pugh,et al.  Cortical pelvic strains with varying size hemiarthroplasty in vitro. , 1989, Journal of biomechanics.

[17]  E. Schneider,et al.  The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. , 2001, Journal of biomechanics.

[18]  H. Hirschfelder,et al.  A computed tomography assessment of femoral and acetabular bone changes after total hip arthroplasty , 2002, International Orthopaedics.

[19]  P. Hunter,et al.  Ventricular mechanics in diastole: material parameter sensitivity. , 2003, Journal of biomechanics.

[20]  Peter Wriggers,et al.  Computational Contact Mechanics , 2002 .

[21]  Angelo Cappello,et al.  Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. , 2004, Journal of biomechanics.

[22]  T D Brown,et al.  In vitro contact stress distributions in the natural human hip. , 1983, Journal of biomechanics.

[23]  P. Pellicci,et al.  Bone Density Adjacent to Press-Fit Acetabular Components: A Prospective Analysis with Quantitative Computed Tomography , 2001, The Journal of bone and joint surgery. American volume.

[24]  D R Carter,et al.  Stress distributions in the acetabular region--I. Before and after total joint replacement. , 1982, Journal of biomechanics.

[25]  D R Pedersen,et al.  An axisymmetric model of acetabular components in total hip arthroplasty. , 1982, Journal of biomechanics.

[26]  H Oonishi,et al.  Mechanical analysis of the human pelvis and its application to the artificial hip joint--by means of the three dimensional finite element method. , 1983, Journal of biomechanics.

[27]  P. Hunter,et al.  Integration from proteins to organs: the Physiome Project , 2003, Nature Reviews Molecular Cell Biology.

[28]  R. Huiskes,et al.  Development and validation of a three-dimensional finite element model of the pelvic bone. , 1995, Journal of biomechanical engineering.

[29]  Justin W. Fernandez,et al.  Anatomically based geometric modelling of the musculo-skeletal system and other organs , 2004, Biomechanics and modeling in mechanobiology.

[30]  C. Dietschi,et al.  Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis. , 1976, Journal of biomechanics.

[31]  M. Raimondi,et al.  Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model. , 2007, Medical engineering & physics.

[32]  E. F. Byars,et al.  EFFECT OF EMBALMING ON THE MECHANICAL PROPERTIES OF BEEF BONE. , 1964, Journal of applied physiology.

[33]  R. Huiskes,et al.  Mechanical and textural properties of pelvic trabecular bone. , 1993, Journal of biomechanics.

[34]  N. Sharkey,et al.  Modified Transverse Locking Nail Fixation of Proximal Femoral Fractures , 1997, Clinical orthopaedics and related research.

[35]  N L Svensson,et al.  Stresses in the normal pelvis. , 1978, Computers in biology and medicine.

[36]  D. J. Rapperport,et al.  Contact finite element stress analysis of porous ingrowth acetabular cup implantation, ingrowth, and loosening , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[37]  Luis Gracia,et al.  Long-term study of bone remodelling after femoral stem: a comparison between dexa and finite element simulation. , 2007, Journal of biomechanics.

[38]  M. Viceconti,et al.  The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. , 2007, Medical engineering & physics.

[39]  J Fisher,et al.  The Influence of Loading Time and Lubricant on the Friction of Articular Cartilage , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[40]  L. E. Malvern Introduction to the mechanics of a continuous medium , 1969 .

[41]  R. Landsberg,et al.  Pelvic stresses in vitro--II. A study of the efficacy of metal-backed acetabular prostheses. , 1986, Journal of biomechanics.

[42]  J. Alonso,et al.  Contact pressures in the flexed hip joint during lateral trochanteric loading , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[43]  A S Greenwald,et al.  The transmission of load through the human hip joint. , 1971, Journal of biomechanics.

[44]  Marco Viceconti,et al.  Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy. , 2006, Journal of biomechanics.

[45]  G. Bergmann,et al.  Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. , 2000, Journal of Biomechanics.

[46]  K. Bathe Finite Element Procedures , 1995 .

[47]  Jan Schmitt,et al.  Femoral strain changes after total hip arthroplasty--patient-specific finite element analyses 12 years after operation. , 2005, Medical engineering & physics.

[48]  D. J. Rapperport,et al.  Contact finite element stress analysis of the hip joint , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[49]  D R Carter,et al.  Stress distributions in the acetabular region--II. Effects of cement thickness and metal backing of the total hip acetabular component. , 1982, Journal of biomechanics.

[50]  T. Santner,et al.  Acetabular cup geometry and bone-implant interference have more influence on initial periprosthetic joint space than joint loading and surgical cup insertion. , 2006, Journal of Biomechanical Engineering.

[51]  P S Walker,et al.  Effects of prosthetic acetabular replacement on strains in the pelvis , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[52]  W R Walsh,et al.  Computational bone remodelling simulations and comparisons with DEXA results , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[53]  D. Hungerford,et al.  The initial stability of uncemented acetabular components. , 1992, The Journal of bone and joint surgery. British volume.