Tunable Laser Diode System for Noninvasive Blood Glucose Measurements

Tight control of blood glucose levels has been shown to dramatically reduce the long-term complications of diabetes. Current invasive technology for monitoring glucose levels is effective but underutilized by people with diabetes because of the pain of repeated finger-sticks and the cost of reagent strips. Optical sensing of glucose could potentially allow more frequent monitoring and tighter glucose control for people with diabetes. The key to a successful optical non-invasive measurement of glucose is the collection of an optical spectrum with a very high signal-to-noise-ratio in a spectral region with significant glucose absorption. Unfortunately, the optical throughput of skin is very small due to absorption and scattering. To overcome these difficulties, we have developed a high-brightness tunable laser system for measurements in the 2.0-2.5 μm wavelength range. The system is based on a 2.3 micron wavelength, strained quantum-well laser diode incorporating GaInAsSb wells and AlGaAsSb barrier and cladding layers. Wavelength control is provided by coupling the laser diode to an external cavity that includes an acousto-optic tunable filter. Tuning ranges of greater than 110 nm have been obtained. Because the tunable filter has no moving parts, scans can be completed very quickly, typically in less than 10 ms. We describe the performance of the laser system and its potential for use in a non-invasive glucose sensor.

[1]  A. Mckellar,et al.  Infrared spectrum of the water–carbon monoxide complex in the CO stretching region , 1998 .

[2]  Martin Walther,et al.  Growth and layer structure optimization of 2.26 μm (AlGaIn)(AsSb) diode lasers for room temperature operation , 2001 .

[3]  N. Ray,et al.  Economic Consequences of Diabetes Mellitus in the U.S. in 1997 , 1998, Diabetes Care.

[4]  W. J. Devlin,et al.  242 nm continuous tuning from a GRIN-SC-MQW-BH InGaAsP laser in an extended cavity , 1990 .

[5]  Minoru Yamada,et al.  An improved analysis of semiconductor laser dynamics under strong optical feedback , 2003 .

[6]  David G. Mehuys,et al.  1 W CW, diffraction-limited, tunable external-cavity semiconductor laser , 1993 .

[7]  George S. Wilson Making an imprint on blood glucose monitoring , 1997, Nature Biotechnology.

[8]  R. Hanson,et al.  In situ combustion measurements of CO with diode-laser absorption near 2.3 microm. , 2000, Applied optics.

[9]  O. Khalil,et al.  Spectroscopic and clinical aspects of noninvasive glucose measurements. , 1999, Clinical chemistry.

[10]  Minoru Yamada,et al.  Field fluctuations and spectral line shape in semiconductor lasers subjected to optical feedback , 2004 .

[11]  Ronald K. Hanson,et al.  A potential remote sensor of CO in vehicle exhausts using 2.3 µm diode lasers , 2000 .

[12]  Ronald Brazg,et al.  A continuous glucose sensor based on wired enzyme technology -- results from a 3-day trial in patients with type 1 diabetes. , 2003, Diabetes technology & therapeutics.

[13]  L. Jovanovic,et al.  Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. , 1999, JAMA.

[14]  A. Cho,et al.  Sensitive absorption spectroscopy with a room-temperature distributed-feedback quantum-cascade laser. , 1998, Optics letters.

[15]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[16]  Martin Walther,et al.  Strain adjustment in (GaIn)(AsSb)/(AlGa)(AsSb) QWs for 2.3–2.7 μm laser structures , 2000 .

[17]  Martin Walther,et al.  Arsenic incorporation in molecular beam epitaxy (MBE) grown (AlGaIn)(AsSb) layers for 2.0–2.5 μm laser structures on GaSb substrates , 1999 .

[18]  Claude Alibert,et al.  Tunable diode laser absorption spectroscopy of carbon monoxide around 2.35 μm , 1998 .

[19]  Martin Walther,et al.  Room-temperature low-threshold low-loss continuous-wave operation of 2.26 μm GaInAsSb/AlGaAsSb quantum-well laser diodes , 2000 .

[20]  F. Capasso,et al.  Quantum-cascade laser measurements of stratospheric methane and nitrous oxide. , 2001, Applied optics.

[21]  Randy D. May,et al.  Open‐path, near‐infrared tunable diode laser spectrometer for atmospheric measurements of H2O , 1998 .

[22]  Hiroshi Ishikawa,et al.  External grating tunable MQW laser with wide tuning range of 240 nm , 1990 .

[23]  Klaus Petermann,et al.  External optical feedback phenomena in semiconductor lasers , 1995, Other Conferences.