Characterization of implantable microfabricated fluid delivery devices

The formal characterization of the performance of microfluidic delivery devices is crucial for reliable in vivo application. A comprehensive laboratory technique was developed and used to optimize, calibrate and validate microfabricated fluid delivery devices. In vivo experiments were carried out to verify the accuracy and reliability of the pressure driven devices. Acute guinea pig experiments were conducted to measure the response to /spl alpha/-amino-3-hydroxy-5-methyl-4-isoxalone propionic acid, an excitatory neurotransmitter, at multiple locations in the inferior colliculus. A nondimensional parameter, Q/spl tilde/, was successfully used to classify devices in terms of geometry alone (i.e., independent of fluid properties). Functional devices exhibited long-term linearity and reliability in delivering single phase, Newtonian fluids, in discrete volumes with a resolution of 500 picoliters at less than 0.45 lbf/in/sup 2/ (30 mbar) pressure drop. Results for non-Newtonian fluids are not presented here. The acute results showed a proportional increase in the firing rate for delivered volumes of 2 nL up to 10 nL (at rates of between 0.1 and 1 nL/s). Flow characteristics are maintained during acute experiments and post-implant. A control experiment conducted with Ringer solution produced negligible effects, suggesting the results to be truly pharmacological. The experimental techniques employed have proven to be reliable and will be used for future calibration and testing of next generation chronic microfluidic delivery devices.

[1]  B. Bellhouse,et al.  Transdermal ballistic delivery of micro-particles: investigation into skin penetration , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[2]  M. Burns,et al.  Microfabrication technologies for integrated nucleic acid analysis. , 1997, Genome research.

[3]  M. Einarson Controlled-release microchip , 1999, Nature Biotechnology.

[4]  K. Wise,et al.  A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery , 2001, Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090).

[5]  Nasser Kehtarnavaz,et al.  Proceedings of SPIE - The International Society for Optical Engineering , 1991 .

[6]  Chang-Jin Kim Microfluidics using the surface tension force in microscale , 2000, SPIE MOEMS-MEMS.

[7]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  Dorian Liepmann,et al.  PLANAR LAMINAR MIXER , 2000 .

[9]  P. Dario,et al.  Micro-systems in biomedical applications , 2000 .

[10]  Jay N. Zemel,et al.  Liquid Transport In Micron And Submicron Channels , 1989, Optics & Photonics.

[11]  J. Chen A Multichannel Neural Probe for Selective Chemical Delivery at the Cellular Level , 1997 .

[12]  Guang Yang,et al.  Modulation transfer function of active pixel focal plane arrays , 2000, Photonics West - Optoelectronic Materials and Devices.

[13]  Göran Stemme,et al.  A sub-micron particle filter in silicon , 1990 .

[14]  R. Shah Laminar Flow Forced convection in ducts , 1978 .

[15]  Raymond MariellaJr.,et al.  MEMS for Bio-Assays , 2002 .

[16]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[17]  M. Allen,et al.  Microfabricated microneedles for gene and drug delivery. , 2000, Annual review of biomedical engineering.

[18]  Brian N. Johnson,et al.  An integrated nanoliter DNA analysis device. , 1998, Science.

[19]  Teruo Fujii,et al.  A microfabricated reactor for cell-free protein synthesis , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[20]  Qu,et al.  Electro-Viscous Effects on Liquid Flow in Microchannels. , 2001, Journal of colloid and interface science.

[21]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[22]  J. Zemel,et al.  Liquid transport in micron and submicron channels , 1990 .

[23]  J. Urquhart,et al.  Controlled drug delivery: therapeutic and pharmacological aspects , 2000 .

[24]  G. Batchelor,et al.  An Introduction to Fluid Dynamics , 1968 .

[25]  M. Cima,et al.  A controlled-release microchip , 1999, Nature.

[26]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[27]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.