Thermal-hydraulic analysis of an innovative decay heat removal system for lead-cooled fast reactors

Abstract Improvement of safety requirements in GEN IV reactors needs more reliable safety systems, among which the decay heat removal system (DHR) is one of the most important. Complying with the diversification criteria and based on pure passive and very reliable components, an additional DHR for the ALFRED reactor (Advanced Lead Fast Reactor European Demonstrator) has been proposed and its thermal-hydraulic performances are analyzed. It consists in a coupling of two innovative subsystems: the radiative-based direct heat exchanger (DHX), and the pool heat exchanger (PHX). Preliminary thermal-hydraulic analyses, by using RELAP5 and RELAP5-3D© computer programs, have been carried out showing that the whole system can safely operate, in natural circulation, for a long term. Sensitivity analyses for: the emissivity of the DHX surfaces, the PHX water heat transfer coefficient (HTC) and the lead HTC have been carried out. In addition, the effects of the density variation uncertainty on the results has been analyzed and compared. It allowed to assess the feasibility of the system and to evaluate the acceptable range of the studied parameters. A comparison of the results obtained with RELAP5 and RELAP5-3D© has been carried out and the analysis of the differences of the two codes for lead is presented. The features of the innovative DHR allow to match the decay heat removal performance with the trend of the reactor decay heat power after shutdown, minimizing at the same time the risk of lead freezing. This system, proposed for the diversification of the DHR in the LFRs, could be applicable in the other pool-type liquid metal fast reactors.

[1]  Hyun-Sik Park,et al.  Experimental study on the natural circulation of a passive residual heat removal system for an integral reactor following a safety related event , 2008 .

[2]  Massimiliano Polidori,et al.  Thermal-hydraulics analyses of ELSY lead fast reactor with open square core option , 2011 .

[3]  Seong-O Kim,et al.  Feasibility Study of a Passive DHR System with Heat Transfer Enhancement Mechanism in a Lead-Cooled Fast Reactor , 2007 .

[4]  Fabio Giannetti,et al.  An innovative pool with a passive heat removal system , 2012 .

[5]  D. Struwe,et al.  European lead fast reactor—ELSY , 2011 .

[6]  A. P. Sorokin,et al.  An experimental study of heat transfer in the core of a BREST-OD-300 reactor with lead cooling on models , 2002 .

[7]  Paride Meloni,et al.  Design, experiments and Relap5 code calculations for the perseo facility , 2005 .

[8]  Eckhard Krepper,et al.  Experimental and numerical investigations of natural circulation phenomena in passive safety systems for decay heat removal in large pools , 2010 .

[9]  A. V. Zhukov,et al.  Heat transfer to liquid metals in regular arrays of fuel elements , 1978 .

[10]  Andrea Alfonsi,et al.  New RELAP5-3D Lead and LBE Thermophysical Properties Implementation for Safety Analysis of Gen IV Reactors , 2016 .

[11]  Ammirabile Luca Guidance Document for Integrated Safety Assessment Methodology (ISAM) - (GDI): EC JRC report prepared for GIF Risk and Safety Working Group , 2014 .

[12]  M. A. Gotovskii,et al.  Heat transfer to liquid metals in longitudinally wetted bundles of rods , 1969 .

[13]  P. Chellapandi,et al.  Decay heat removal in pool type fast reactor using passive systems , 2012 .

[14]  Konstantin Mikityuk,et al.  Heat transfer to liquid metal: Review of data and correlations for tube bundles , 2009 .

[15]  T. C. Hung,et al.  CFD modeling and thermal-hydraulic analysis for the passive decay heat removal of a sodium-cooled fast reactor , 2011 .

[16]  A. John Arul,et al.  Functional reliability analysis of Safety Grade Decay Heat Removal System of Indian 500 MWe PFBR , 2008 .

[17]  Fabio Manni,et al.  Innovative radiation-based direct heat exchanger (DHX) for liquid metal cooled reactors , 2013 .

[18]  Luciano Burgazzi,et al.  Confronto e valutazione della risposta di sistemi attivi e passivi in reattori innovativi a fronte di sequenze incidentali significative ai fini della sicurezza , 2013 .

[19]  A. John Arul,et al.  Reliability analysis of safety grade decay heat removal system of Indian prototype fast breeder reactor , 2006 .