Estimating 3D L5/S1 moments and ground reaction forces during trunk bending using a full-body ambulatory inertial motion capture system.

Inertial motion capture (IMC) systems have become increasingly popular for ambulatory movement analysis. However, few studies have attempted to use these measurement techniques to estimate kinetic variables, such as joint moments and ground reaction forces (GRFs). Therefore, we investigated the performance of a full-body ambulatory IMC system in estimating 3D L5/S1 moments and GRFs during symmetric, asymmetric and fast trunk bending, performed by nine male participants. Using an ambulatory IMC system (Xsens/MVN), L5/S1 moments were estimated based on the upper-body segment kinematics using a top-down inverse dynamics analysis, and GRFs were estimated based on full-body segment accelerations. As a reference, a laboratory measurement system was utilized: GRFs were measured with Kistler force plates (FPs), and L5/S1 moments were calculated using a bottom-up inverse dynamics model based on FP data and lower-body kinematics measured with an optical motion capture system (OMC). Correspondence between the OMC+FP and IMC systems was quantified by calculating root-mean-square errors (RMSerrors) of moment/force time series and the interclass correlation (ICC) of the absolute peak moments/forces. Averaged over subjects, L5/S1 moment RMSerrors remained below 10Nm (about 5% of the peak extension moment) and 3D GRF RMSerrors remained below 20N (about 2% of the peak vertical force). ICCs were high for the peak L5/S1 extension moment (0.971) and vertical GRF (0.998). Due to lower amplitudes, smaller ICCs were found for the peak asymmetric L5/S1 moments (0.690-0.781) and horizontal GRFs (0.559-0.948). In conclusion, close correspondence was found between the ambulatory IMC-based and laboratory-based estimates of back load.

[1]  Jack T Dennerlein,et al.  A novel method for assessing the 3-D orientation accuracy of inertial/magnetic sensors. , 2013, Journal of biomechanics.

[2]  Sunwook Kim,et al.  Performance evaluation of a wearable inertial motion capture system for capturing physical exposures during manual material handling tasks , 2013, Ergonomics.

[3]  Michael J. Agnew,et al.  Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion. , 2009, Journal of biomechanical engineering.

[4]  Monique H W Frings-Dresen,et al.  Assessing the work-relatedness of nonspecific low-back pain. , 2005, Scandinavian journal of work, environment & health.

[5]  Alison Godwin,et al.  INVESTIGATING THE FEASIBILITY OF NEW METHODS FOR ANALYSIS AND COLLECTION OF HUMAN MOTION IN FIELD APPLICATIONS , 2009 .

[6]  Monique H. W. Frings-Dresen,et al.  Epidemiologic evidence on manual materials handling as a risk factor for back disorders:a systematic review , 1999 .

[7]  I. Kingma,et al.  Cumulative Low Back Load at Work as a Risk Factor of Low Back Pain: A Prospective Cohort Study , 2012, Journal of Occupational Rehabilitation.

[8]  A. Plamondon,et al.  Validation of two 3-D segment models to calculate the net reaction forces and moments at the L(5)/S(1) joint in lifting. , 1996, Clinical biomechanics.

[9]  Jack T. Dennerlein,et al.  Estimating dynamic external hand forces during manual materials handling based on ground reaction forces and body segment accelerations. , 2013, Journal of biomechanics.

[10]  E. Vieira,et al.  Risk factors for work-related musculoskeletal disorders: A systematic review of recent longitudinal studies. , 2009, American journal of industrial medicine.

[11]  Idsart Kingma,et al.  Determination of joint moments with instrumented force shoes in a variety of tasks. , 2010, Journal of biomechanics.

[12]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[13]  P. Veltink,et al.  Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  Bernadette A. Thomas,et al.  Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010 , 2012, The Lancet.

[15]  J H van Dieën,et al.  Working height, block mass and one- vs. two-handed block handling: the contribution to low back and shoulder loading during masonry work , 2009, Ergonomics.

[16]  Idsart Kingma,et al.  Bottom-up estimation of joint moments during manual lifting using orientation sensors instead of position sensors. , 2010, Journal of biomechanics.

[17]  A Plamondon,et al.  Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion. , 2007, Applied ergonomics.

[18]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[19]  Rolf Ellegast,et al.  Quantitative measurement of stressful trunk postures in nursing professions. , 2007, The Annals of occupational hygiene.

[20]  I. Kingma,et al.  Validation of a full body 3-D dynamic linked segment model , 1996 .

[21]  R. Norman,et al.  A comparison of peak vs cumulative physical work exposure risk factors for the reporting of low back pain in the automotive industry. , 1998, Clinical biomechanics.

[22]  P. Veltink,et al.  Ambulatory measurement of the knee adduction moment in patients with osteoarthritis of the knee. , 2013, Journal of biomechanics.

[23]  Laura Rocchi,et al.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors , 2008, Medical & Biological Engineering & Computing.

[24]  A Leardini,et al.  Position and orientation in space of bones during movement: anatomical frame definition and determination. , 1995, Clinical biomechanics.

[25]  F. Lötters,et al.  Are changes in mechanical exposure and musculoskeletal health good performance indicators for primary interventions? , 2002, International archives of occupational and environmental health.

[26]  Jennifer M. Neugebauer,et al.  Ground Reaction Force Estimates from ActiGraph GT3X+ Hip Accelerations , 2014, PloS one.

[27]  D. Roetenberg,et al.  Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors , 2009 .

[28]  Steven A Lavender,et al.  Instrumentation for measuring dynamic spinal load moment exposures in the workplace. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.