Analysis of leakage flux distributions in a salient-pole synchronous machine using finite elements
暂无分享,去创建一个
[1] Rafael Escarela-Perez,et al. A novel finite-element transient computation of two-axis parameters of solid-rotor generators for use in power systems , 1998 .
[2] Nabeel A. O. Demerdash,et al. Coupled finite-element/state-space modeling of turbogenerators in the abc frame of reference-the short-circuit and load cases including saturated parameters , 1995 .
[3] S. Tandon,et al. Load Characteristics of Synchronous Generators by the Finite-Element Method , 1981, IEEE Transactions on Power Apparatus and Systems.
[4] S. Nasar,et al. A general equivalent circuit (GEC) of electric machines including cross-coupling saturation and frequency effects , 1988 .
[5] Gordon R. Slemon. An equivalent circuit approach to analysis of synchronous machines with saliency and saturation , 1990 .
[6] Kazumasa Ide,et al. Analysis of saturated synchronous reactances of large turbine generator by considering cross-magnetizing reactances using finite elements , 1999 .
[7] A.B.J. Reece,et al. Turbine-generator steady-state reactances , 1985 .
[8] G. W. Buckley,et al. The Effects of Saturation on the Armature Leakage Reactance of Large Synchronous Machines , 1984, IEEE Power Engineering Review.
[9] Kazumasa Ide,et al. Variation of Saturated Reactances of a Salient-Pole Synchronous Motor in the Field-Weakening Region , 1997 .
[10] Toshiro Matsumura,et al. Development of a Synchronous Generator Model founded on a Permeance-based Air-Gap Flux Density Analysis , 1991 .
[11] Kazumasa Ide,et al. Calculation of leakage inductances of a salient-pole synchronous machine using finite elements , 1999 .
[12] J.W. Dougherty,et al. Finite Element Modeling of Large Turbine Generators; Calculations Versus Load Test Data , 1981, IEEE Transactions on Power Apparatus and Systems.
[13] L. A. Kilgore,et al. Calculation of Synchronous Machine Constants- Reactances and Time Constants Affecting Transient Characteristics , 1931, Transactions of the American Institute of Electrical Engineers.
[14] I. M. Canay,et al. Causes of Discrepancies on Calculation of Rotor Quantities and Exact Equivalent Diagrams of the Synchronous Machine , 1969 .
[15] Innocent Kamwa,et al. A two-factor saturation model for synchronous machines with multiple rotor circuits , 1995 .