Towards a Modular Suturing Catheter for Minimally Invasive Vascular Surgery

Endovascular aneurysm repair (EVAR) is a minimally invasive approach for abdominal aortic aneurysm (AAA) treatment. Compared to open surgery, the benefits of EVAR include faster recovery and shorter time in hospital as well as no general anesthesia (in most cases). Though EVAR has become a preferred way to treat AAA with an increasing number of procedures, there are persisting complications, e.g. stent graft migration. Suturing the stent graft to the aorta increases the displacement force necessary to move the implant. This paper describes the design of a suturing catheter for EVAR. The suturing device consist of two modules which can be inserted through the femoral arteries into the abdominal aorta where both join using an electro-magnetic connector. The positioning module provides an anchor inside the aorta for the suturing module and new sequential positions for each stitch. Our large-scale prototype is validated inside a phantom vessel made of silicone material. We are able to successfully prove the concept of this novel single-sided suturing catheter for EVAR.

[1]  M. Morasch,et al.  Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses. , 1996, The Journal of thoracic and cardiovascular surgery.

[2]  Martin Buss,et al.  Automation of a suturing device for minimally invasive surgery , 2011, Surgical Endoscopy.

[3]  Kaspar Althoefer,et al.  A Novel Concept for Safe, Stiffness-Controllable Robot Links. , 2017, Soft robotics.

[4]  Axel Krieger,et al.  Smart Tissue Anastomosis Robot (STAR): A Vision-Guided Robotics System for Laparoscopic Suturing , 2014, IEEE Transactions on Biomedical Engineering.

[5]  A. Kapoor,et al.  Suturing in confined spaces: constrained motion control of a hybrid 8-DoF robot , 2005, ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005..

[6]  T. Huber Outcomes Following Endovascular vs Open Repair of Abdominal Aortic Aneurysm: A Randomized Trial , 2010 .

[7]  Y. Gouëffic,et al.  Long-Term Results of Large Stent Grafts to Treat Abdominal Aortic Aneurysms. , 2015, Annals of vascular surgery.

[8]  L. V. von Segesser,et al.  Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  Haifeng Luo,et al.  Suturing and tying knots assisted by a surgical robot system in laryngeal MIS , 2009, Robotica.

[10]  Daniel Martins,et al.  New Kinematic Structures For One-side Stitching Devices , 2015 .

[11]  Hiniduma Lokuge,et al.  Design of remote endoscopic suturing device , 2003 .

[12]  A. Cuschieri,et al.  Essential Surgical Practice: Higher Surgical Training in General Surgery , 2015 .

[13]  A. Halliday The United Kingdom EVAR Trial Investigators. Endovascular versus Open Repair of Abdominal Aortic Aneurysm , 2010 .

[14]  K. Komori,et al.  Long-term Comparison of Endovascular and Open Repair of Abdominal Aortic Aneurysms: Retrospective Analysis of Matched Cohorts with Propensity Score. , 2017, Annals of vascular surgery.

[15]  Kaspar Althoefer,et al.  Embedded electro-conductive yarn for shape sensing of soft robotic manipulators , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[16]  A. Moritz,et al.  The Heartflo device for distal coronary anastomoses: clinical experiences in 60 patients. , 2002, The Annals of thoracic surgery.

[17]  Santosh Iyer,et al.  A single arm, single camera system for automated suturing , 2013, 2013 IEEE International Conference on Robotics and Automation.

[18]  A. Saratzis,et al.  Helical EndoStaples enhance endograft fixation in an experimental model using human cadaveric aortas. , 2012, Journal of vascular surgery.

[19]  Kaspar Althoefer,et al.  Tendon and pressure actuation for a bio-inspired manipulator based on an antagonistic principle , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[20]  Axel Krieger,et al.  Smart Tissue Anastomosis Robot (STAR): Accuracy evaluation for supervisory suturing using near-infrared fluorescent markers , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[21]  Alois Knoll,et al.  Automation of tissue piercing using circular needles and vision guidance for computer aided laparoscopic surgery , 2010, 2010 IEEE International Conference on Robotics and Automation.

[22]  Kaspar Althoefer,et al.  Image-Based Optical Miniaturized Three-Axis Force Sensor for Cardiac Catheterization , 2016, IEEE Sensors Journal.

[23]  Wyatt S. Newman,et al.  Real-Time Visual Tracking of Dynamic Surgical Suture Threads , 2018, IEEE Transactions on Automation Science and Engineering.

[24]  Kaspar Althoefer,et al.  Lecture Notes in Computer Science: An Antagonistic Actuation Technique for Simultaneous Stiffness and Position Control , 2015, ICIRA.

[25]  P. Peduzzi,et al.  Outcomes following endovascular vs open repair of abdominal aortic aneurysm: a randomized trial. , 2009, JAMA.

[26]  A. Giannoukas,et al.  Systematic review and meta-analysis of migration after endovascular abdominal aortic aneurysm repair , 2016, Vascular.

[27]  Kenneth Y. Goldberg,et al.  Automating multi-throw multilateral surgical suturing with a mechanical needle guide and sequential convex optimization , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[28]  Mamoru Mitsuishi,et al.  Preliminary study of needle tracking in a microsurgical robotic system for automated operations , 2013, 2013 13th International Conference on Control, Automation and Systems (ICCAS 2013).

[29]  C. Zarins,et al.  The association between iliac fixation and proximal stent-graft migration during EVAR follow-up: mid-term results of 154 Talent devices. , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[30]  Allison M. Okamura,et al.  Tissue property estimation and graphical display for teleoperated robot-assisted surgery , 2009, 2009 IEEE International Conference on Robotics and Automation.

[31]  Christopher K Zarins,et al.  The importance of iliac fixation in prevention of stent graft migration. , 2006, Journal of vascular surgery.

[32]  T. Resch,et al.  The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. , 2000, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[33]  Thomas Looi,et al.  KidsArm — An image-guided pediatric anastomosis robot , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[34]  A. Moritz,et al.  Sutured Coronary Artery Grafting Utilizing the Heartflo™ Anastomosis Device - First Clinical Experiences , 2002, The Thoracic and cardiovascular surgeon.