Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump

Geothermal heat pump technology is currently one of the most interesting technologies used to heat buildings. There are two designs used in the industry: geothermal heat pump using a secondary ground loop and Direct Expansion (DX) ground source heat pump. The latter is less used, possibly because less research has been carried out for the design of this kind of heat pump. In this paper, a transient model using the Comsol Multiphysic of a DX ground heat pump is presented in heating mode with R22, and a comparison with experimental results is presented with a 24-hour test. It is shown that the model was adequately validated by our experiment with only a maximum difference of 15%. Following this validation, a parametric analysis was realised on the geometry of the borehole. This study concluded that to have the best heat extraction of the ground, the pipes shank spacing need to be important without increasing the borehole diameter. Article History : Received January 16 th 2017; Received in revised form May 28 th 2017; Accepted June 6 th 2017; Available online How to Cite This Article : Rousseau, C., Fannou, J.L.C., Lamarche, L. and Kajl, S. (2017) Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump. International Journal of Renewable Energy Development, 6(2), 145-155. https://doi.org/10.14710/ijred.6.2.145-155

[1]  Yuanwei Lu,et al.  An experimental study of a direct expansion ground‐coupled heat pump system in heating mode , 2009 .

[2]  Michele De Carli,et al.  Design of borehole heat exchangers for ground-source heat pumps: A literature review, methodology comparison and analysis on the penalty temperature , 2012 .

[3]  Stephen White,et al.  Modelling the performance of a transcritical CO2 heat pump for high temperature heating , 2002 .

[4]  Mustafa Inalli,et al.  Modelling of a vertical ground coupled heat pump system by using artificial neural networks , 2009, Expert Syst. Appl..

[5]  J. R. Goulburn,et al.  Domestic heat pump with deep hole ground source evaporator , 1983 .

[6]  Mohamed Ouzzane,et al.  Modeling of a two-phase CO2-filled vertical borehole for geothermal heat pump applications , 2014 .

[7]  K. Sumathy,et al.  Parametric study on the performance of a direct-expansion geothermal heat pump using carbon dioxide , 2011 .

[8]  J. R. Goulburn,et al.  Deep ground coil evaporators for heat pumps , 1978 .

[9]  C. Montagud,et al.  Reference data sets for validating GSHP system models and analyzing performance parameters based on a five-year operation period , 2014 .

[10]  S. Garimella,et al.  Heat Transfer and Pressure Drop Characteristics of Spirally Fluted Annuli: Part II—Heat Transfer , 1995 .

[11]  Louis Lamarche,et al.  Experimental analysis of a direct expansion geothermal heat pump in heating mode , 2014 .

[12]  S. Garimella,et al.  Heat Transfer and Pressure Drop Characteristics of Spirally Fluted Annuli: Part I—Hydrodynamics , 1995 .

[13]  J. Vargas,et al.  Simulation in transient regime of a heat pump with closed-loop and on-off control , 1995 .

[14]  J. C. Chen Correlation for Boiling Heat Transfer to Saturated Fluids in Convective Flow , 1966 .

[15]  V. Gnielinski New equations for heat and mass transfer in the turbulent flow in pipes and channels , 1975 .

[16]  A. Miyara,et al.  Condensation heat transfer of binary refrigerant mixtures of R22 and R114 inside a horizontal tube with internal spiral grooves , 1990 .

[17]  Stanislaw Kajl,et al.  Modeling and experimental validation of a transient direct expansion geothermal heat exchanger , 2015 .

[18]  김대성,et al.  Geothermal heat pump , 2011 .

[19]  Louis Lamarche,et al.  Semi-analytical model for geothermal borefields with independent inlet conditions , 2016 .

[20]  Marc A. Rosen,et al.  Geothermal heat pump systems: Status review and comparison with other heating options , 2013 .

[21]  Michel Bernier,et al.  Dynamic model of a hermetic reciprocating compressor in on–off cycling operation (Abbreviation: Compressor dynamic model) , 2010 .

[22]  E. A. Freund,et al.  Earth source heat pumps: Characteristics, design, and operation , 1959, Transactions of the American Institute of Electrical Engineers, Part II: Applications and Industry.

[23]  G. Hellström Ground heat storage : thermal analyses of duct storage systems , 1991 .

[24]  Stanisław,et al.  A Numerical Model of a U-Tube Vertical Ground Heat Exchanger Used as an Evaporator , 2013 .

[25]  Zhihao Chen,et al.  Experimental investigation on the operation performance of a direct expansion ground source heat pump system for space heating , 2013 .