A system to measure the kinematics during the entire ski jump sequence using inertial sensors.
暂无分享,去创建一个
Julien Favre | Kamiar Aminian | Julien Chardonnens | Florian Cuendet | Gérald Gremion | K. Aminian | G. Gremion | J. Favre | J. Chardonnens | Florian Cuendet
[1] Julien Favre,et al. Automatic measurement of key ski jumping phases and temporal events with a wearable system , 2012, Journal of sports sciences.
[2] John Weston,et al. Strapdown Inertial Navigation Technology , 1997 .
[3] Marco Parvis,et al. Procedure for effortless in-field calibration of three-axial rate gyro and accelerometers , 1995 .
[4] D. Roetenberg,et al. Estimating Body Segment Orientation by Applying Inertial and Magnetic Sensing Near Ferromagnetic Materials , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[5] B M Jolles,et al. Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance. , 2010, Journal of biomechanics.
[6] K. Spring. Euler parameters and the use of quaternion algebra in the manipulation of finite rotations: A review , 1986 .
[7] Maurice R. Yeadon,et al. A Multisegment Dynamic Model of Ski Jumping , 1989 .
[8] Julien Favre,et al. An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system. , 2012, Journal of biomechanics.
[9] K. Aminian,et al. Ambulatory measurement of 3D knee joint angle. , 2008, Journal of biomechanics.
[10] D. Bates,et al. Mixed-Effects Models in S and S-PLUS , 2001 .
[11] Julien Favre,et al. A wearable system to assess risk for anterior cruciate ligament injury during jump landing: measurements of temporal events, jump height, and sagittal plane kinematics. , 2011, Journal of biomechanical engineering.
[12] K. Aminian,et al. A comparison between joint coordinate system and attitude vector for multi-segment foot kinematics. , 2012, Journal of biomechanics.
[13] Pascal Fua,et al. Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors , 2006, IEEE Transactions on Biomedical Engineering.
[14] Peter H. Veltink,et al. Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.
[15] T. Andriacchi,et al. Characterization of thigh and shank segment angular velocity during jump landing tasks commonly used to evaluate risk for ACL injury. , 2012, Journal of biomechanical engineering.
[16] Simon M. Luethi,et al. Methodological Problems in Optimization of the Flight Phase in Ski Jumping , 1987 .
[17] M P Kadaba,et al. On the estimation of joint kinematics during gait. , 1991, Journal of biomechanics.
[18] Richard C. Nelson. Introduction to Sport Biomechanics , 1980 .
[19] Julien Favre,et al. Measurement of multi-segment foot joint angles during gait using a wearable system. , 2012, Journal of biomechanical engineering.
[20] E S Grood,et al. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.
[21] Mikko Virmavirta,et al. Techniques Used by Olympic Ski Jumpers in the Transition From Takeoff to Early Flight , 1995 .
[22] Naser El-Sheimy,et al. A Standard Testing and Calibration Procedure for Low Cost MEMS Inertial Sensors and Units , 2008, Journal of Navigation.
[23] Hermann Schwameder,et al. Biomechanics research in ski jumping, 1991–2006 , 2008, Sports biomechanics.
[24] J. Bortz. A New Mathematical Formulation for Strapdown Inertial Navigation , 1971, IEEE Transactions on Aerospace and Electronic Systems.
[25] Maurice R. Yeadon. A Method for Obtaining Three-Dimensional Data on Ski Jumping Using Pan and Tilt Cameras , 1989 .
[26] Valentina Camomilla,et al. Countermovement jump performance assessment using a wearable 3D inertial measurement unit , 2011, Journal of sports sciences.
[27] W Müller,et al. Individual flight styles in ski jumping: results obtained during Olympic Games competitions. , 2005, Journal of biomechanics.
[28] T. Andriacchi,et al. Inertial Sensor-Based Feedback Can Reduce Key Risk Metrics for Anterior Cruciate Ligament Injury During Jump Landings , 2012, The American journal of sports medicine.
[29] Erich Müller,et al. Collecting kinematic data on a ski/snowboard track with panning, tilting, and zooming cameras: Is there sufficient accuracy for a biomechanical analysis? , 2010, Journal of sports sciences.
[30] B M Jolles,et al. Functional calibration procedure for 3D knee joint angle description using inertial sensors. , 2009, Journal of biomechanics.
[31] A. Cappozzo,et al. Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.
[32] K. Aminian,et al. Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement , 2006 .
[33] P. de Leva. Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters. , 1996, Journal of biomechanics.