First double-sided 3-D detectors fabricated at CNM-IMB

The first results on double-sided three-dimensional (3-D) silicon radiation detectors are reported in this paper. The detector consists of a three-dimensional array of electrodes that penetrate into the detector bulk with the anode and cathode electrodes etched from opposite sides of the substrate. The geometry of the detector is such that a central anode is surrounded by four cathode contacts. The maximum drift and depletion distances are equal to the electrode spacing rather than detector thickness. This structure is similar to a conventional 3-D detector, but has a simpler fabrication process. The technological and the electrical simulations together with the fabrication steps of this new detector configuration are reported in this paper. The first detectors fabricated at CNM are reported here and have been characterized by electrical measurements.

[1]  Keith Mathieson,et al.  Technology development of 3D detectors for high-energy physics and imaging , 2002 .

[2]  C. Da Via,et al.  Radiation hardness properties of full-3D active edge silicon sensors , 2008 .

[3]  P. Allport,et al.  Performances of miniature microstrip detectors made on oxygen enriched p-type substrates after very high proton irradiation , 2004 .

[4]  The ATLAS pixel detector , 2005 .

[5]  C. Lacasta,et al.  Ultimate limits for the radiation hardness of silicon strip detectors for sLHC , 2007 .

[6]  Michael Moll,et al.  RD50 status report 2006: Radiation hard semiconductor devices for very high luminosity colliders , 2007 .

[7]  G. Lutz,et al.  Semiconductor Radiation Detectors: Device Physics , 1999 .

[8]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[9]  Sherwood Parker,et al.  Silicon detectors with 3-D electrode arrays: fabrication and initial test results , 1999 .

[10]  M. Campbell,et al.  Signal variations in high-granularity Si pixel detectors , 2004, IEEE Transactions on Nuclear Science.

[11]  K. Kano Semiconductor Devices , 1997 .

[12]  R. Bates,et al.  Simulation Results From Double-Sided 3-D Detectors , 2006, IEEE Transactions on Nuclear Science.

[13]  G. Pellegrini,et al.  Performance limits of a 55-/spl mu/m pixel CdTe detector , 2006, IEEE Transactions on Nuclear Science.

[14]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[15]  S. Stapnes,et al.  Physics potential and experimental challenges of the LHC luminosity upgrade , 2002, hep-ph/0204087.

[16]  Sherwood Parker,et al.  Active-edge planar radiation sensors. , 2006, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.