Heat removal from a triangular finned flat-plate solar-energy collector
暂无分享,去创建一个
For a fin-and-tube header-and-riser arrangement of a flat-plate solar-energy collector, the effect of triangular tapering of the absorber fins attached to each riser has been analysed. The heat-removal factor for each triangular fin is greater than for a rectangular fin of the same base width but lower than that of a rectangular fin of the same magnitude of absorber surface area.
[1] W. Beckman,et al. Solar Engineering of Thermal Processes , 1985 .
[2] J. Mackerle. Air-Cooled Automobile Engines , 1961 .
[3] Kirk D. Hagen. Perturbation analysis of tapered fins with nonlinear thermal properties , 1988 .
[4] S. D. Probert,et al. Thermal resistance of a solar-energy collector absorber under a non-uniform flux distribution , 1988 .