Hot box measurements of pumice aggregate concrete hollow block walls

Abstract Due to its relatively low thermal conductivity characteristics and being a local product, pumice aggregate concrete (PAC) blocks are increasingly used as a masonry wall unit in Turkey. However, there is limited technical and scientific knowledge on hygrothermal performance of PAC blocks. A research project is conducted to study hygrothermal performance of PAC block walls using a calibrated hot box method. Temperature and humidity measurements were carried out at the surfaces of the test wall and in the hollows of blocks on different courses. The results, in general, indicate that the hollows of blocks perform better in terms of thermal transmittance than the lightweight solid parts of them. Noticeable changes are observed in hygrothermal behaviour of the lower and the upper courses depending on the indoor and outdoor climate test conditions. The heterogeneous material and rough surface characteristics of the blocks, in addition to the wet construction type of block wall are the most problematic issues that make measurements and assessments difficult.

[1]  Jean-Jacques Roux,et al.  Reduced linear state model of hollow blocks walls, validation using hot box measurements , 2004 .

[2]  Targo Kalamees,et al.  Hygrothermal calculations and laboratory tests on timber-framed wall structures , 2003 .

[3]  Mark Bomberg,et al.  Integrated Methodology for Evaluation of Energy Performance of Building Enclosures: Part II — Examples of Application to Residential Walls , 2008 .

[4]  Dominique Derome,et al.  Comparison of experimental and numerical results of wood-frame wall assemblies wetted by simulated wind-driven rain infiltration , 2007 .

[5]  Paul Fazio,et al.  Environmental Chamber for Investigation of Building Envelope Performance , 1997 .

[6]  Mesut B. Özdeniz HYGROTHERMAL PERFORMANCE OF A NEW BRIQUETTE DESIGN , 1996 .

[7]  Hartwig M. Künzel,et al.  Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope , 2005 .

[8]  Pietro Stefanizzi,et al.  Hygro-thermal performance of hollow bricks and current standards , 2001 .

[9]  P. J. García Nieto,et al.  Non-linear thermal analysis of light concrete hollow brick walls by the finite element method and experimental validation , 2006 .

[10]  Mark Bomberg,et al.  Integrated Methodology for Evaluation of Energy Performance of the Building Enclosures — Part 1: Test Program Development , 2008 .

[11]  K. Ghazi Wakili,et al.  U-value of a dried wall made of perforated porous clay bricks Hot box measurement versus numerical analysis , 2003 .