Real-time stability testing of air-dried primers and fluorogenic hydrolysis probes stabilized by trehalose and xanthan.

A method for conserving primers and differently labeled fluorogenic hydrolysis (i.e., TaqMan) probes at ambient conditions is presented. Primers and hydrolysis probes with four different fluorophore-quencher combinations (6- FAM-BHQ1, HEX-BHQ1, ROX-BHQ650, and Cy5-BHQ2) were mixed with trehalose and xanthan at final concentrations of 56 mM and 2.78 mM, respectively. Mixtures were air-dried at 23°C for 30 min on strips composed of cyclo olefin polymer (COP), a material widely used in the manufacturing of in vitro diagnostic (IVD) test carriers. After one year of storage, the functionality of the primers and fluorophore-quencher combinations was validated by real-time polymerase chain reaction (real-time PCR), confirming their stability when stored in the presence of stabilizers, with the best results achieved using trehalose. This approach could be of great benefit for manufacturing IVD systems, for example, for genotyping applications based on multiplexing using different fluorescent dyes.

[1]  W. Saenger Structure and dynamics of water surrounding biomolecules. , 1987, Annual review of biophysics and biophysical chemistry.

[2]  C. Colaco,et al.  Extraordinary Stability of Enzymes Dried in Trehalose: Simplified Molecular Biology , 1992, Bio/Technology.

[3]  D S Reid,et al.  Is trehalose special for preserving dry biomaterials? , 1996, Biophysical journal.

[4]  K. Livak,et al.  Real time quantitative PCR. , 1996, Genome research.

[5]  A. Pühler,et al.  Xanthan gum biosynthesis and application: a biochemical /genetic perspective , 1998, Applied Microbiology and Biotechnology.

[6]  J. Carpenter,et al.  The role of vitrification in anhydrobiosis. , 1998, Annual review of physiology.

[7]  J. Casas,et al.  Xanthan gum: production, recovery, and properties. , 2000, Biotechnology Advances.

[8]  C. N. Gundry,et al.  Real-time multiplex PCR assays. , 2001, Methods.

[9]  John Comley qPCR ASSAYS end user practices and latest vendor offerings , 2008 .

[10]  R. Zengerle,et al.  Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. , 2010, Chemical Society reviews.

[11]  Pedro S. Nunes,et al.  Cyclic olefin polymers: emerging materials for lab-on-a-chip applications , 2010 .

[12]  Roland Zengerle,et al.  Centrifugal microfluidic system for primary amplification and secondary real-time PCR. , 2010, Lab on a chip.

[13]  Aarthy Palaniraj,et al.  Production, recovery and applications of xanthan gum by Xanthomonas campestris , 2011 .

[14]  A. Lampen,et al.  Preservation of primer and probes on “ready-to-use” 96-well microtiter plates: A step forward towards enhancing throughput and harmonization of real-time PCR applications in food and feed control , 2012 .

[15]  Martina Hitzbleck,et al.  Reagents in microfluidics: an 'in' and 'out' challenge. , 2013, Chemical Society reviews.

[16]  Roland Zengerle,et al.  Multiplex genotyping of KRAS point mutations in tumor cell DNA by allele-specific real-time PCR on a centrifugal microfluidic disk segment , 2014, Microchimica Acta.