Myocardial blood flow quantitation in patients with congestive heart failure: head-to-head comparison between rapid-rotating gantry SPECT and CZT SPECT

PurposeRecently, the feasibility of myocardial blood flow (MBF) quantitation using rapid-rotating gantry (RRG) and cadmium–zinc–telluride (CZT) SPECT cameras has been demonstrated. We compared MBF quantitation using these two camera systems.MethodsTwenty patients with congestive heart failure (CHF) and 20 patients without CHF (non-CHF) were included. On two consecutive days, dynamic SPECT imaging was performed after a bolus injection of 20 mCi of 99mTc-Sestamibi (MIBI) with RRG-SPECT and list-mode acquisition with CZT-SPECT. All dynamic SPECT images were reconstructed with full physical corrections, corrections for ventricular spillover and partial volume effect, using one-tissue kinetic modeling. Resting MBF converted from K1 was then corrected for MIBI extraction fraction and adjusted for rate-pressure product.ResultsIn both patient groups, there was no significant difference between resting MBF values measured with RRG-SPECT and CZT-SPECT systems (P = 0.06, P = 0.2 respectively). For CHF patients, linear regression (LR) was y(RRG) = 1.0412x (CZT) (r = 0.97) with a small systemic difference (Δ = 0.03 mL·min−1·g−1, 95% CI − 0.11 to 0.20) by Bland–Altman analysis. For non-CHF patients, LR was y(RRG) = 1.025x (CZT) (r = 0.89) with also small systemic difference (ΔT= 0.02 mL·min−1·g−1, 95% CI − 0.14 to 0.19) in BA analysis.ConclusionPhysical corrections along with other image corrections can provide comparable MBF quantitations in both CHF and non-CHF patients, regardless of the type of SPECT systems used.

[1]  Lei Wang,et al.  Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation , 2017, Journal of Nuclear Cardiology.

[2]  Denis Mariano-Goulart,et al.  SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements , 2015, The Journal of Nuclear Medicine.

[3]  L. Shao,et al.  A generalized model for the conversion from CT numbers to linear attenuation coefficients , 2002 .

[4]  Wen-Sheng Huang,et al.  Feasibility and operator variability of myocardial blood flow and reserve measurements with 99mTc-sestamibi quantitative dynamic SPECT/CT imaging , 2014, Journal of Nuclear Cardiology.

[5]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[6]  Terrence D. Ruddy,et al.  Optimization of SPECT Measurement of Myocardial Blood Flow with Corrections for Attenuation, Motion, and Blood Binding Compared with PET , 2017, The Journal of Nuclear Medicine.

[7]  Leonid Tsukerman,et al.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[8]  Stephen J. Glick,et al.  Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations , 2005, IEEE Transactions on Medical Imaging.

[9]  Johan Nuyts,et al.  Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[10]  M. Phelps,et al.  Influence of Age and Hemodynamics on Myocardial Blood Flow and Flow Reserve , 1993, Circulation.

[11]  Quanzheng Li,et al.  Quantitative Statistical Methods for Image Quality Assessment , 2013, Theranostics.

[12]  Yen-Kung Chen,et al.  SPECT myocardial blood flow quantitation toward clinical use: a comparative study with 13N-Ammonia PET myocardial blood flow quantitation , 2016, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  Ran Klein,et al.  Short-term repeatability of resting myocardial blood flow measurements using rubidium-82 PET imaging , 2012, Journal of Nuclear Cardiology.

[14]  P. Slomka,et al.  Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study , 2013, The Journal of Nuclear Medicine.

[15]  Ran Klein,et al.  Quantification of myocardial blood flow and flow reserve: Technical aspects , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[16]  Alain Manrique,et al.  First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study , 2018, European Journal of Nuclear Medicine and Molecular Imaging.

[17]  K. Ogawa,et al.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Michael Fiechter,et al.  Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium–Zinc–Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET , 2016, The Journal of Nuclear Medicine.

[19]  Shaoying Liu,et al.  Collimator-detector response compensation in quantitative SPECT reconstruction , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[20]  M. Miyagawa,et al.  Performance of a semiconductor SPECT system: comparison with a conventional Anger-type SPECT instrument , 2012, Annals of Nuclear Medicine.

[21]  Wen-Sheng Huang,et al.  Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease , 2014, European Journal of Nuclear Medicine and Molecular Imaging.