Low-pressure membrane integrity tests for drinking water treatment: A review.

Low-pressure membrane systems, including microfiltration (MF) and ultrafiltration (UF) membranes, are being increasingly used in drinking water treatments due to their high level of pathogen removal. However, the pathogen will pass through the membrane and contaminate the product if the membrane integrity is compromised. Therefore, an effective on-line integrity monitoring method for MF and UF membrane systems is essential to guarantee the regulatory requirements for pathogen removal. A lot of works on low-pressure membrane integrity tests have been conducted by many researchers. This paper provides a literature review about different low-pressure membrane integrity monitoring methods for the drinking water treatment, including direct methods (pressure-based tests, acoustic sensor test, liquid porosimetry, etc.) and indirect methods (particle counting, particle monitoring, turbidity monitoring, surrogate challenge tests). Additionally, some information about the operation of membrane integrity tests is presented here. It can be realized from this review that it remains urgent to develop an alternative on-line detection technique for a quick, accurate, simple, continuous and relatively inexpensive evaluation of low-pressure membrane integrity. To better satisfy regulatory requirements for drinking water treatments, the characteristic of this ideal membrane integrity test is proposed at the end of this paper.

[1]  Munir Cheryan,et al.  Ultrafiltration and Microfiltration Handbook , 1998 .

[2]  Graham Pearce,et al.  Water and wastewater filtration: Membrane module format , 2007 .

[3]  Wei Zhang,et al.  Membrane characterization using porosimetry and contact angle measurements: a comparison with experimental ultrafiltration results , 1989 .

[4]  Graham A. Gagnon,et al.  Indirect integrity testing on a pilot-scale UF membrane , 2005 .

[5]  B. Roffel,et al.  Statistical analysis of data from accelerated ageing tests of PES UF membranes , 2007 .

[6]  Robert M. Clark,et al.  Application of nanoscale probes for the evaluation of the integrity of ultrafiltration membranes , 2006 .

[7]  Peer C. Kamp,et al.  Development of a membrane integrity monitoring strategy for the UF/RO Heemskerk drinking water treatment plant , 2001 .

[8]  James H. Naismith,et al.  Membrane integrity — direct turbidity measurement of filtrate from MF membrane modules at an operating potable water treatment plant , 2005 .

[9]  Jan Hofman,et al.  Fiber failure frequency and causes of hollow fiber integrity loss , 2006 .

[10]  D. Bursill,et al.  Drinking water treatment-understanding the processes and meeting the challenges , 2001 .

[11]  Waldo A. Steiner,et al.  Separation of Gases by Fractional Permeation through Membranes , 1950 .

[12]  P. Lipp,et al.  Characterization of nanoparticulate fouling and breakthrough during low-pressure membrane filtration , 2009 .

[13]  Benito Jose Marinas,et al.  Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit , 2002 .

[14]  Anthony Bennett,et al.  Maintaining the integrity of filtration systems , 2005 .

[15]  M W Phillips,et al.  A validatible porosimetric technique for verifying the integrity of virus-retentive membranes. , 1996, Biologicals : journal of the International Association of Biological Standardization.

[16]  Z. Do-Quang,et al.  Assessment of a particle counting method for hollow fiber membrane integrity , 1997 .

[17]  Atsushi Hashimoto,et al.  Experimental Assessment of the Efficacy of Microfiltration and Ultrafiltration for Cryptosporidium R , 1998 .

[18]  Khosrow Farahbakhsh,et al.  Monitoring the Integrity of low‐pressure membranes , 2003 .

[19]  Samer Adham,et al.  Assessing the Reliability of Low Pressure Membrane Systems for Microbial Removal , 1994 .

[20]  Robert M. Clark,et al.  Nanoscale probes for the evaluation of the integrity of ultrafiltration membranes , 2006 .

[21]  Anthony G. Fane,et al.  Novel membrane-based sensor for online membrane integrity monitoring , 2008 .

[22]  Nandakishore Rajagopalan,et al.  Use of paramagnetic particles in membrane integrity testing , 2008 .

[23]  Pierre Aimar,et al.  Study of the effects of defects in ultrafiltration membranes on the water flux and the molecular weight cut-off , 2002 .

[24]  Khosrow Farahbakhsh,et al.  Estimating air diffusion contribution to pressure decay during membrane integrity tests , 2004 .

[25]  Alasdair Donn,et al.  Membrane solution to a significant risk Cryptosporidium groundwater source , 2001 .

[26]  Satoshi Takizawa,et al.  Effects of nanoparticles on the ultrafiltration of surface water , 2009 .

[27]  Nicola Randles,et al.  Large scale operating experience in membrane systems for water and waste water reclamation , 1997 .

[28]  R. Field,et al.  Critical flux concept for microfiltration fouling , 1995 .

[29]  Ralf Kuriyel,et al.  A liquid porosimetry technique for correlating intrinsic protein sieving: Applications in ultrafiltration processes , 1997 .

[30]  Sal Giglia,et al.  High sensitivity binary gas integrity test for membrane filters , 2008 .

[31]  P. Trimboli,et al.  Demonstrating the integrity of a large scale microfiltration plant using a Bacillus spore challenge test , 2001 .

[32]  Warren T. Johnson,et al.  Automatic monitoring of membrane integrity in microfiltration systems , 1997 .

[33]  Avner Adin,et al.  Fluorescent dye labeled bacteriophages--a new tracer for the investigation of viral transport in porous media: 1. Introduction and characterization. , 2002, Water research.

[34]  J. Lozier,et al.  Monitoring membrane integrity using high sensitivity laser turbidimetry , 2001 .

[35]  Jean-Michel Laine,et al.  Risk management approach for monitoring UF membrane integrity and experimental validation using Ms2-phages , 2008 .

[36]  Keith E. Carns,et al.  Low‐Pressure Membrane Filtration for Removing Giardia and Microbial Indicators , 1991 .

[37]  J. Howell,et al.  Sub-critical flux operation of microfiltration , 1995 .

[38]  Warren T. Johnson,et al.  Predicting log removal performance of membrane systems using in-situ integrity testing , 1998 .

[39]  Stefan Panglisch,et al.  Monitoring the integrity of capillary membranes by particle counters , 1998 .

[40]  Anthony Bennett,et al.  Drinking water: Pathogen removal from water – technologies and techniques , 2008 .

[41]  Samer Adham,et al.  Low‐pressure membranes: assessing integrity , 1995 .

[42]  K. Glucina,et al.  Acoustic sensor: a novel technique for low pressure membrane integrity monitoring☆ , 1998 .