Signal processing of the fetal electrocardiogram.

There has been considerable interest in recent years in the monitoring of the well-being of the fetus by the analysis of changes in morphology of the fetal electrocardiogram (FECG) signal. In this article, a brief review is first made of the use of the scalp electrode method to obtain an enhanced FECG complex. Subsequently, the problems in extracting the fetal signal from measurements taken from the abdomen of the mother are discussed. A comparison is made between two existing algorithms to extract the fetal signal: (1) the method of Akselrod; and (2) the adaptive filtering algorithm of Widrow. These algorithms are evaluated by considering the errors that could occur in locating the fetal R wave in the presence of noise.

[1]  D. L. Kirk,et al.  Techniques for the routine on-line processing of the fetal electrocardiogram , 1986, Journal of perinatal medicine.

[2]  E. Hon,et al.  Instrumentation of fetal electrocardiography. , 1957, Science.

[3]  O. H. Schmitt,et al.  Report of committee on electrocardiography, American Heart Association. Recommendations for standardization of leads and of specifications for instruments in electrocardiography and vectorcardiography. , 1967, Circulation.

[4]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[5]  C J Marvell,et al.  A simple software routine for the reproducible processing of the electrocardiogram. , 1980, Journal of biomedical engineering.

[6]  V D Saini,et al.  Computerized detection of low-level fetal signals in the maternal abdominal electrocardiogram. , 1985, Computers in biology and medicine.

[7]  V. Thomas Rhyne,et al.  Digital signal enchancement of the fetal electrocardiogram , 1968 .

[8]  Piet Bergveld,et al.  A New Technique for the Suppression of the MECG , 1981, IEEE Transactions on Biomedical Engineering.

[9]  Joos Vandewalle,et al.  Two Methods for Optimal MECG Elimination and FECG Detection from Skin Electrode Signals , 1987, IEEE Transactions on Biomedical Engineering.

[10]  J Janssens,et al.  Description of a real-time system to extract the fetal electrocardiogram. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[11]  A. Oosterom,et al.  Spatial filtering of the fetal electrocardiogram , 1986, Journal of perinatal medicine.

[12]  S. Larks THE FETAL ELECTROCARDIOGRAM IN MULTIPLE PREGNANCY , 1959, American journal of obstetrics and gynecology.

[13]  C J Marvell,et al.  The use of labour profiles in assessing the behaviour of the fetal electrocardiogram. , 1980, Journal of biomedical engineering.

[14]  E. Hon,et al.  NOISE REDUCTION IN FETAL ELECTROCARDIOGRAPHY. II. AVERAGING TECHNIQUES. , 1963, American journal of obstetrics and gynecology.

[15]  S. Cerutti,et al.  Variability analysis of fetal heart rate signals as obtained from abdominal electrocardiographic recordings , 1986, Journal of perinatal medicine.

[16]  M. P. Watts,et al.  Trends in electrocardiograph design , 1987 .

[17]  S Abboud,et al.  Power spectrum analysis of fetal heart rate variability using the abdominal maternal electrocardiogram. , 1990, Journal of biomedical engineering.

[18]  R. L. Longini,et al.  Abdominal-Lead Fetal Electrocardiographic R-Wave Enhancement for Heart Rate Determination , 1980, IEEE Transactions on Biomedical Engineering.

[19]  J. Nagel Progresses in Fetal Monitoring by Improved Data Acquisition , 1984, IEEE Engineering in Medicine and Biology Magazine.