The radiated fields of focussing air-coupled ultrasonic phased arrays.

This paper presents an investigation into the fields radiated into air by ultrasonic phased arrays under transient excitation. In particular, it includes a theoretical prediction of spatial variations in amplitude throughout the both the near-field and far-field of such arrays. The approach has been used to predict the result of phasing to produce a focus in air, which can be seen to be particularly effective in the near-field of the array. Interesting features are observed, which are then described in terms of the performance of both individual elements and the resulting array. It is shown how some elements of design can be used to improve performance in focussing. The predictions are compared to the results of experiments in air using electrostatic arrays, where good focussing could be achieved provided the appropriate design principles were followed. The approach has been developed specifically for use in air, but the results would also hold for modelling in certain medical arrays where a focussing requirement might be needed close to the array itself.

[1]  Philip Webb,et al.  High-resolution beam forming for ultrasonic arrays , 1996, IEEE Trans. Robotics Autom..

[2]  Randy L. Haupt,et al.  Introduction to Adaptive Arrays , 1980 .

[3]  C Wykes,et al.  The performance of capacitive ultrasonic transducers using v-grooved backplates , 1991 .

[4]  J.L. San Emeterio,et al.  A new algorithm to calculate the transient near-field of ultrasonic phased arrays , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  H. Torp,et al.  Which transducer array is best , 1995 .

[6]  N. Suzuki,et al.  A linear-array freehand 3-D endoscopic ultrasound. , 2003, Ultrasound in medicine & biology.

[7]  A. Freedman Sound Field of a Rectangular Piston , 1960 .

[8]  D. W. Schindel,et al.  Ultrasonic imaging of solid surfaces using a focussed air-coupled capacitance transducer , 1998 .

[9]  K. Suzuki,et al.  A silicon electrostatic ultrasonic transducer , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  S. M. Kramer,et al.  Characteristics of wide-band planar ultrasonic transducers using plane and edge wave contributions , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Michael Moles,et al.  Phased array ultrasonic inspection of Friction Stir Weldments , 2000 .

[12]  Shi-Chang Wooh,et al.  A Simulation Study of the Beam Steering Characteristics for Linear Phased Arrays , 1999 .

[13]  W.S.H. Munro,et al.  Arrays for airborne 100 kHz ultrasound , 1994 .

[14]  Charles J Bruce,et al.  Intracardiac phased-array imaging: methods and initial clinical experience with high resolution, under blood visualization: initial experience with intracardiac phased-array ultrasound. , 2002, Journal of the American College of Cardiology.

[15]  Shi-Chang Wooh,et al.  Optimum beam steering of linear phased arrays , 1999 .

[16]  L. Rayleigh,et al.  The theory of sound , 1894 .

[17]  David A. Hutchins,et al.  Advances in ultrasonic electrostatic transduction , 1998 .

[18]  David A. Hutchins,et al.  An air-coupled line-focused capacitive ultrasonic transducer , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[19]  A. G. Bashford,et al.  Focussing of ultrasonic waves in air using a micromachined Fresnel zone-plate , 1997 .

[20]  Shi-Chang Wooh,et al.  Influence of phased array element size on beam steering behavior , 1998 .

[21]  Adrian Neild Ultrasonic air-coupled capacitive arrays , 2003 .

[22]  J. C. Lockwood,et al.  High‐speed method for computing the exact solution for the pressure variations in the nearfield of a baffled piston , 1973 .

[23]  David A. Hutchins,et al.  Capacitive and piezoelectric air-coupled transducers for resonant ultrasonic inspection , 1996 .

[24]  D. Schindel,et al.  The design and characterization of micromachined air-coupled capacitance transducers , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  José Luis San Emeterio,et al.  Diffraction impulse response of rectangular transducers , 1992 .

[26]  W. Wilkening,et al.  Brain perfusion and ultrasonic imaging techniques. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[27]  Toby James Gray Robertson Advances in ultrasonic capacitive transducer technology , 2001 .

[28]  C. Wykes,et al.  Diagnostic measurements in capacitive transducers , 1993 .

[29]  M. Lethiecq,et al.  Experimental investigation of electrostatic ultrasonic transducers with grooved backplates , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[30]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[31]  D. Cosgrove,et al.  Advances in ultrasound. , 2002, Clinical radiology.

[32]  Sung-Jin Song,et al.  Development of an ultra sonic phased array system for nondestructive tests of nuclear power plant components , 2002 .

[33]  Shi-Chang Wooh,et al.  Three-dimensional beam directivity of phase-steered ultrasound , 1999 .

[34]  R. Gibney,et al.  Technical report. Intra-operative ultrasound-guided needle localization for impalpable testicular lesions. , 2003, Clinical radiology.