Reduced-Capacity Inrush Current Suppressor Using a Matrix Converter in a Wind Power Generation System with Squirrel-Cage Induction Machines

This paper describes the reduced capacity of the inrush current suppressor using a matrix converter (MC) in a large-capacity wind power generation system (WPGS) with two squirrel-cage induction machines (SCIMs). These SCIMs are switched over depending on the wind speed. The input side of the MC is connected to the source in parallel. The output side of the MC is connected in series with the SCIM through matching transformers. The modulation method of the MC used is direct duty ratio pulse width modulation. The reference output voltage of the MC is decided by multiplying the SCIM current with the variable control gain. Therefore, the MC performs as resistors for the inrush current. Digital computer simulation is implemented to confirm the validity and practicability of the proposed inrush current suppressor using PSCAD/EMTDC (power system computer-aided design/electromagnetic transients including DC). Furthermore, the equivalent resistance of the MC is decided by the relationship between the equivalent resistance and the capacity of the MC. Simulation results demonstrate that the proposed inrush current suppressor can suppress the inrush current perfectly.

[1]  A. Alesina,et al.  Analysis and design of optimum-amplitude nine-switch direct AC-AC converters , 1989 .

[2]  Yukihiko Sato,et al.  A Space Vector Modulation Scheme for Matrix Converter that Gives Top Priority to the Improvement of the Output Control Performance , 2008 .

[3]  Byung-Moon Han,et al.  Direct Duty Ratio Pulse Width Modulation Method for Matrix Converters , 2008 .

[4]  T. Petru,et al.  Flicker contribution from wind turbine installations , 2004, IEEE Transactions on Energy Conversion.

[5]  Elías Jesús Medina-Domínguez,et al.  Critical Clearing Time and Wind Power in Small Isolated Power Systems Considering Inertia Emulation , 2015 .

[6]  T. Hanamoto,et al.  A novel method of suppressing inrush currents of squirrel-cage induction machine using matrix converter in wind power generation systems , 2014, 2012 International Conference on Renewable Energy Research and Applications (ICRERA).

[7]  佐藤 以久也,et al.  キャリア比較方式を用いた仮想AC/DC/AC変換方式によるマトリックスコンバータの制御法 , 2004 .

[8]  Seung-Ki Sul,et al.  Carrier-based Modulation Method for Matrix Converter with Input Power Factor Control and under Unbalanced Input Voltage Conditions , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[9]  Kichiro Yamamoto,et al.  Compensation for Harmonic Currents and Reactive Power in Wind Power Generation System using PWM Inverter , 2004 .

[10]  T. Thiringer Grid-Friendly Connecting of Constant-Speed Wind Turbines Using External Resistors , 2002, IEEE Power Engineering Review.

[11]  Yoshitaka Minari,et al.  Compensation for Magnetizing Inrush Currents in Transformers using PWM Inverter , 2001 .

[12]  Wei Xu,et al.  A New Method of Compensating Harmonic Currents for Wind Power Generation Systems with the Soft Starter Using A Hybrid Active Filter , 2007, 2007 Power Conversion Conference - Nagoya.

[13]  Johann W. Kolar,et al.  A Review of Control and Modulation Methods for Matrix Converters , 2012, IEEE Transactions on Industrial Electronics.

[14]  T. Higuchi,et al.  Analysis of Control Performance of Matrix Converter in a High-speed Region using Circuit Simulator , 2007, 2007 Power Conversion Conference - Nagoya.

[15]  Jun-ichi Itoh,et al.  A control method for the matrix converter based on virtual AC/DC/AC conversion using carrier comparison method , 2005 .