Economic feasibility of thermal energy storage systems

This paper investigates the economic feasibility of both building an ice thermal storage and structure a time of rate tariff for the unique air conditioning (A/C) plant of the Grand Holy Mosque of Makkah, Saudi Arabia. The features of the building are unique where the air-conditioned 39,300 m 2 zone is open to the atmosphere and the worshippers fully occupy the building five times a day, in addition hundreds of thousands of worshippers attend the blessed weekend’s prayer at noontime, which escalates the peak electricity load. For economic analysis, the objective function is the daily electricity bill that includes the operation cost and the capital investment of the ice storage system. The operationcost is functionof the energyimportedfor operating theplant in which the tariffstructure, number of operatinghours and the ambient temperature are parameters. The capital recoveryfactor is calculated for 10% interest rate and payback period of 10 years. Full and partial load storage scenarios are considered. The results showed that with the current fixed electricity rate (0.07 $/kWh), there is no gain in introducing ice storage systems for both storage schemes. Combining energy storage and an incentive time structured rate showed reasonable daily bill savings. For base tariff of 0.07 $/kWh during daytime operation and 0.016 $/kWh for off-peak period, savings were achieved for full load storage scenario. Different tariff structure is discussed and the break-even nighttime rate was determined (varies between 0.008 and 0.03 $/kWh). Partial load storage scenario showed to be unattractive where the savings for the base structured tariff was insignificant. # 2006 Elsevier B.V. All rights reserved.

[1]  Moncef Krarti,et al.  Guidelines for improved performance of ice storage systems , 2003 .

[2]  J. L. Peterson,et al.  Component models for computer simulation of ice storage systems , 1989 .

[3]  S. M. Hasnain,et al.  Need for thermal-storage air-conditioning in Saudi Arabia , 2000 .

[4]  A. R. de L. Musgrove,et al.  Optimum design and operation of ice-storage air-conditioning systems under Australian TOU tariffs , 1989 .

[5]  A. Saito Recent advances in research on cold thermal energy storage , 2002 .

[6]  Yousef S.H. Najjar,et al.  Augmentation of gas turbine performance using air coolers , 2004 .

[7]  Moncef Krarti,et al.  A Simulation Environment for the Analysis of Ice Storage Controls , 1997 .

[8]  C. E. Dorgan,et al.  ASHRAE's new design guide for cool thermal storage , 1994 .

[9]  Moncef Krarti,et al.  Ice Storage System Controls for the Reduction of Operating Cost and Energy Use , 1998 .

[10]  Shijun You,et al.  Partial ice-storage: Application to air conditioning systems in Hong Kong , 1999 .

[11]  Moncef Krarti,et al.  Development of a thermal energy storage model for EnergyPlus , 2004 .

[12]  A. Rudin,et al.  Design for the future by looking at the past , 1997 .

[13]  Michael D. Haughey Ice Thermal Storage for Colorado School. , 2003 .

[14]  Keisuke Onishi Thermal storage air conditioning system in subway station building , 2002 .

[15]  Moncef Krarti,et al.  Parametric analysis of active and passive building thermal storage utilization , 2005 .

[16]  James E. Braun,et al.  Modeling partial charging and discharging of area-constrained ice storage tanks , 1999 .

[17]  J. W. Jones,et al.  Evaluation of RP-459 algorithms for modeling external melt, ice-on-pipe thermal storage system components , 1995 .

[18]  S. M. Hasnain,et al.  Prospects of cool thermal storage utilization in Saudi Arabia , 2000 .