Low Power Personalized ECG Based System Design Methodology for Remote Cardiac Health Monitoring

This paper describes a mixed-signal electrocardiogram (ECG) system for personalized and remote cardiac health monitoring. The novelty of this paper is fourfold. First, a low power analog front end with an efficient automatic gain control mechanism, maintaining the input of the ADC to a level rendering optimum SNR and the enhanced recyclic folded cascode opamp used as an integrator for ΣΔ ADC. Second, a novel on-the-fly PQRST boundary detection (BD) methodology is formulated for finding the boundaries in continuous ECG signal. Third, a novel low-complexity ECG feature extraction architecture is designed by reusing the same module present in the proposed BD methodology. Fourth, the system is having the capability to reconfigure the proposed low power ADC for low (8 b) and high (12 b) resolution with the use of the feedback signal obtained from the digital block when it is in processing. The proposed system has been tested and validated on patient's data from PTBDB, CSEDB, and in-house IIT Hyderabad Data Base (IITHDB) and we have achieved an accuracy of 99% upon testing on various normal and abnormal ECG signals. The whole system is implemented in 180-nm technology resulting in 9.47-μW (at 1 MHz) power consumption and occupying 1.74-mm2 silicon area.

[1]  Gian Franco Gensini,et al.  A Clinician’s View of Next-Generation Remote Healthcare System , 2014 .

[2]  Minkyu Je,et al.  800 nW 43 nV/√Hz neural recording amplifier with enhanced noise efficiency factor , 2012 .

[3]  J. Goes,et al.  A 0.9V /spl Delta//spl Sigma/ Modulator with 80dB SNDR and 83dB DR Using a Single-Phase Technique , 2006, 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers.

[4]  Koushik Maharatna,et al.  Design of a Low-Power On-Body ECG Classifier for Remote Cardiovascular Monitoring Systems , 2013, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[5]  Amit Acharyya,et al.  A Low-Complexity ECG Feature Extraction Algorithm for Mobile Healthcare Applications , 2013, IEEE Journal of Biomedical and Health Informatics.

[6]  Gabor C. Temes,et al.  A 75-dB SNDR, 5-MHz Bandwidth Stage-Shared 2-2 MASH ΔΣ Modulator Dissipating 16 mW Power. , 2012 .

[7]  Hiroshi Nakajima,et al.  A Wearable Healthcare System With a 13.7 $\mu$ A Noise Tolerant ECG Processor , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[8]  Gabor C. Temes,et al.  A 75-dB SNDR, 5-MHz Bandwidth Stage-Shared 2–2 MASH $\Delta \Sigma$ Modulator Dissipating 16 mW Power , 2012, IEEE Transactions on Circuits and Systems I: Regular Papers.

[9]  D. Schmitt-Landsiedel,et al.  A 0.7V MOSFET-only switched-opamp /spl Sigma//spl Delta/ modulator , 2002, 2002 IEEE International Solid-State Circuits Conference. Digest of Technical Papers (Cat. No.02CH37315).

[10]  Herbert F. Jelinek,et al.  ECG Biometric with Abnormal Cardiac Conditions in Remote Monitoring System , 2014, IEEE Transactions on Systems, Man, and Cybernetics: Systems.

[11]  Refet Firat Yazicioglu,et al.  A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[12]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[13]  Yingchieh Ho,et al.  A 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications , 2014, IEEE Journal of Solid-State Circuits.

[14]  Yong Ping Xu,et al.  A Compact, Low Input Capacitance Neural Recording Amplifier , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[15]  Shuenn-Yuh Lee,et al.  A 0.6-V 1.8-μW automatic gain control circuit for digital hearing aid , 2008, APCCAS 2008 - 2008 IEEE Asia Pacific Conference on Circuits and Systems.

[16]  P. Patra,et al.  An enhanced fully differential Recyclic Folded Cascode OTA , 2012, International Multi-Conference on Systems, Sygnals & Devices.

[17]  José Silva-Martínez,et al.  The Recycling Folded Cascode: A General Enhancement of the Folded Cascode Amplifier , 2009, IEEE Journal of Solid-State Circuits.

[18]  Shey-Shi Lu,et al.  A pliable and batteryless real-time ECG monitoring system-in-a-patch , 2015, VLSI Design, Automation and Test(VLSI-DAT).

[19]  Recommendations for measurement standards in quantitative electrocardiography. The CSE Working Party. , 1985, European heart journal.

[20]  Pachamuthu Rajalakshmi,et al.  Adaptive rule engine based IoT enabled remote health care data acquisition and smart transmission system , 2014, 2014 IEEE World Forum on Internet of Things (WF-IoT).

[21]  Yong Lian,et al.  A 1-V 450-nW Fully Integrated Programmable Biomedical Sensor Interface Chip , 2009, IEEE Journal of Solid-State Circuits.

[22]  Amit Acharyya,et al.  Signal Processing Architecture Implementation Methodologies for Next-Generation Remote Healthcare Systems , 2014 .

[23]  Xiaoyang Zeng,et al.  An Ultra-Low Power QRS Complex Detection Algorithm Based on Down-Sampling Wavelet Transform , 2013, IEEE Signal Processing Letters.

[24]  Christopher M. Twigg,et al.  A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[25]  Refet Firat Yazicioglu,et al.  A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSP , 2015, IEEE Journal of Solid-State Circuits.

[26]  J. Goes,et al.  3.7 A 0.9V ∆Σ Modulator with 80dB SNDR and 83dB DR Using a Single-Phase Technique , 2006 .