MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation

Objective: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). Method: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. Results: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. Conclusion: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. Significance: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.

[1]  Greig C. Scott,et al.  An Optically Coupled System for Quantitative Monitoring of MRI-Induced RF Currents Into Long Conductors , 2010, IEEE Transactions on Medical Imaging.

[2]  Paul A Bottomley,et al.  Radiofrequency Ablation, MR Thermometry, and High-Spatial-Resolution MR Parametric Imaging with a Single, Minimally Invasive Device. , 2016, Radiology.

[3]  Alireza Mehrtash,et al.  Real‐time active MR‐tracking of metallic stylets in MR‐guided radiation therapy , 2015, Magnetic resonance in medicine.

[4]  Ergin Atalar,et al.  In Vivo Magnetic Resonance Imaging of Mesenchymal Stem Cells in Myocardial Infarction , 2003, Circulation.

[5]  R. Mallozzi,et al.  Phase‐field dithering for active catheter tracking , 2010, Magnetic resonance in medicine.

[6]  Ergin Atalar,et al.  Modeling of radio-frequency induced currents on lead wires during MR imaging using a modified transmission line method. , 2011, Medical physics.

[7]  Anthony Z. Faranesh,et al.  Segmented nitinol guidewires with stiffness-matched connectors for cardiovascular magnetic resonance catheterization: preserved mechanical performance and freedom from heating , 2015, Journal of Cardiovascular Magnetic Resonance.

[8]  Mark E Ladd,et al.  Spatial distribution of RF‐induced E‐fields and implant heating in MRI , 2008, Magnetic resonance in medicine.

[9]  Bernard De Bruyne,et al.  Fractional Flow Reserve, Coronary Pressure Wires, and Drift. , 2016, Circulation journal : official journal of the Japanese Circulation Society.

[10]  Volkmar Schulz,et al.  Transmission line for improved RF safety of interventional devices , 2005, Magnetic resonance in medicine.

[11]  Sung-Min Park,et al.  Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer function , 2007, Journal of magnetic resonance imaging : JMRI.

[12]  I. R. Young,et al.  Magneto-Inductive Catheter Receiver for Magnetic Resonance Imaging , 2013, IEEE Transactions on Biomedical Engineering.

[13]  Graham A. Wright,et al.  Miniaturizing Floating Traps to Increase RF Safety of Magnetic-Resonance-Guided Percutaneous Procedures , 2017, IEEE Transactions on Biomedical Engineering.

[14]  L Darrasse,et al.  Optimization of NMR receiver bandwidth by inductive coupling. , 1992, Magnetic resonance imaging.

[15]  W. Nitz,et al.  On the heating of linear conductive structures as guide wires and catheters in interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[16]  Toby Rogers,et al.  Interventional CMR: Clinical Applications and Future Directions , 2015, Current Cardiology Reports.

[17]  Toby Rogers,et al.  Real-time inversion recovery for infarct visualization during MR-guided interventions , 2016, Journal of Cardiovascular Magnetic Resonance.

[18]  Alastair J. Martin,et al.  Safety of retained microcatheters: an evaluation of radiofrequency heating in endovascular microcatheters with nitinol, tungsten, and polyetheretherketone braiding at 1.5 T and 3 T , 2013, Journal of NeuroInterventional Surgery.

[19]  Robert G. Weiss,et al.  Magnetic Resonance Assessment of the Substrate for Inducible Ventricular Tachycardia in Nonischemic Cardiomyopathy , 2005, Circulation.

[20]  G. Mckinnon,et al.  Vascular interventions guided by ultrafast MR imaging: Evaluation of different materials , 1994, Magnetic resonance in medicine.

[21]  Matthias Gutberlet,et al.  Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[22]  J C Ehrhardt,et al.  Prediction of tumor control in patients with cervical cancer: analysis of combined volume and dynamic enhancement pattern by MR imaging. , 2000, AJR. American journal of roentgenology.

[23]  Mark A. Griswold,et al.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter , 2016, IEEE Transactions on Biomedical Engineering.

[24]  Ergin Atalar,et al.  Magnetic resonance image‐guided trans‐septal puncture in a swine heart , 2005, Journal of magnetic resonance imaging : JMRI.

[25]  Ehud J Schmidt,et al.  MRI use for atrial tissue characterization in arrhythmias and for EP procedure guidance , 2017, The International Journal of Cardiovascular Imaging.

[26]  Derek Seeber,et al.  Floating shield current suppression trap , 2004 .

[27]  Aravindan Kolandaivelu,et al.  Non‐contrast‐enhanced T1‐weighted MRI of myocardial radiofrequency ablation lesions , 2018, Magnetic resonance in medicine.

[28]  G. Randy Duensing,et al.  Common mode signal rejection methods for MRI: Reduction of cable shield currents for high static magnetic field systems , 2003 .

[29]  H. Ho,et al.  Safety of metallic implants in magnetic resonance imaging , 2001, Journal of magnetic resonance imaging : JMRI.

[30]  Ergin Atalar,et al.  of the 23 rd Annual EMBS International Conference , October 25-28 , Istanbul , Turkey RF Safety of Wires in Interventional MRI : Using a Safety Index , 2004 .

[31]  R. Kim,et al.  Magnetic resonance imaging for the assessment of myocardial viability , 2004, Journal of magnetic resonance imaging : JMRI.

[32]  Christian Kirisits,et al.  Image guided adaptive brachytherapy with combined intracavitary and interstitial technique improves the therapeutic ratio in locally advanced cervical cancer: Analysis from the retroEMBRACE study. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  J. Bird Electrical Circuit Theory and Technology, 5th ed , 2013 .