EDEL: ENEA DOSEMETER FOR EYE LENS.

Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of Hp(3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements.

[1]  D. Bartlett,et al.  The MCNP-4C2 design of a two element photon/electron dosemeter that uses magnesium/copper/phosphorus doped lithium fluoride. , 2007, Radiation protection dosimetry.

[2]  P. Ferrari,et al.  First results of an eye lens dosimetry survey in an interventional cardiology department , 2015, Journal of radiological protection : official journal of the Society for Radiological Protection.

[3]  S. Mattsson,et al.  Eye lens dosimetry for interventional procedures - Relation between the absorbed dose to the lens and dose at measurement positions , 2011 .

[4]  E. Fantuzzi,et al.  A new cylindrical phantom for eye lens dosimetry development , 2011 .

[5]  R. Czarwinski Implications of the implementation of the reduced dose limits for the lens of the eye: an IRPA activity. , 2013, Journal of radiological protection : official journal of the Society for Radiological Protection.

[6]  A. Auvinen,et al.  A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists. , 2013, Radiation protection dosimetry.

[7]  R Behrens,et al.  Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualities. , 2012, Radiation protection dosimetry.

[8]  T. Olgar,et al.  Assessment of radiation doses to cardiologists during interventional examinations. , 2009, Medical physics.

[9]  F. Vanhavere,et al.  Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED project , 2011 .

[10]  E. Fantuzzi,et al.  Characterisation of a Personal TL Photon Dosemeter Based on Two LiF(Mg,Cu,P) Detectors in Terms of Hp(0.07,a) and Hp(10,a) , 1999 .

[11]  G. O'reilly,et al.  Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. , 2013, The British journal of radiology.

[12]  Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom. , 2013, Radiation protection dosimetry.

[13]  E P Efstathopoulos,et al.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures. , 2011, The British journal of radiology.

[14]  J H Hendry,et al.  ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection Context , 2012, Annals of the ICRP.

[15]  C J Martin,et al.  A review of radiology staff doses and dose monitoring requirements. , 2009, Radiation protection dosimetry.

[16]  G Gualdrini,et al.  ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,alpha). , 2011, Radiation protection dosimetry.

[17]  M. Pelliccioni,et al.  On the Conversion Coefficients from Fluence to Ambient Dose Equivalent , 1994 .