Fan Noise Suppression

The principal suppressor parameters and their relationships have been used to formulate a suppressor design methodology which has been applied to the design of several full-scale suppressors. Tests of these suppressors on several full-scale fans have demonstrated noise reductions of the order of 10 PNdB. The amount of suppression in several instances seems to have been limited by reaching noise floors that are not clearly at the estimated jet noise level but are not far above it. In addition to identifying noise floors, two other areas are considered. The first is attenuation by the fan exhaust suppressors, which seems in most cases to be less than that of the inlet. The second is the effectiveness of outer cowl treatment alone on multiple pure tones. This question relates to whether a high-speed fan can become as quiet as a low-speed fan without a substantial increase in the amount of treatment.