Assessing the flexural and axial behaviour of reinforced concrete members at elevated temperatures using sectional analysis

Simplified, rational, and practical models that account for the effect of elevated temperature on concrete and steel properties are needed. These models will enable engineers to design and assess reinforced concrete (RC) structures to satisfy specific fire performance criteria. This paper introduces a simple method that predicts the flexural and axial behaviour of RC sections during exposure to elevated temperatures. The method is based on using finite difference analysis to estimate the temperature distribution within a concrete section and a modified version of the well-known sectional analysis approach to predict the axial and/or flexural behaviour. A rational approach is proposed to convert the two-dimensional temperature distribution to a one-dimensional distribution. This approach converts a complex problem to a simplified one and thus enables engineers to better understand the behaviour and have higher confidence in the results. The predictions of the proposed method are validated using experimental and analytical studies by others. Additional tests are needed to further validate and improve the proposed method.

[1]  S. Thelandersson,et al.  Stress and Deformation Characteristics of Concrete at High Temperatures. 2. Experimental Investigation and Material Behaviour Model , 1976 .

[2]  H. L. Malhotra Design of fire-resisting structures , 1982 .

[3]  Mohamad J. Terro,et al.  Numerical Modeling of the Behavior of Concrete Structures in Fire , 1998 .

[4]  D. Mitchell,et al.  Prestressed Concrete Basics , 1994 .

[5]  Yong Wang,et al.  Designers' guide to EN1991-1-2, EN1992-1-2, EN1993-1-2, and EN1994-1-2. , 2007 .

[6]  M. Sultan,et al.  EFFECT OF TEMPERATURE ON THERMAL PROPERTIES OF HIGH-STRENGTH CONCRETE , 2003 .

[7]  T. T. Lie,et al.  FIRE RESISTANCE OF REINFORCED CONCRETE COLUMNS , 1992 .

[8]  Venkatesh Kodur,et al.  Performance-based Fire Safety Design of Reinforced Concrete Beams: , 2007 .

[9]  Maged A. Youssef,et al.  Simplified seismic modelling of reinforced concrete flexural members , 2007 .

[10]  Yao Yao,et al.  Fire resistance of reinforced concrete columns. , 2002 .

[11]  Venkatesh Kodur,et al.  Effect of Strength and Fiber Reinforcement on Fire Resistance of High-Strength Concrete Columns , 2003 .

[12]  Ulf Wickström,et al.  A very simple method for estimating temperaturein fire exposed concrete structures , 1986 .

[13]  G. Khoury Effect of fire on concrete and concrete structures , 2000 .

[14]  Venkatesh Kodur,et al.  A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams , 2008 .

[15]  Miran Saje,et al.  The effects of different strain contributions on the response of RC beams in fire , 2007 .

[16]  Kristian Dahl Hertz,et al.  Concrete strength for fire safety design , 2005 .

[17]  Arthur H. Nilson,et al.  Design of concrete structures , 1972 .

[18]  T. A. Lie Fire and buildings , 1972 .

[19]  T. T. Lie,et al.  Structural fire protection , 1992 .

[20]  Maged A. Youssef,et al.  General stress–strain relationship for concrete at elevated temperatures , 2007 .

[21]  Jose L. Torero,et al.  Behaviour of concrete structures in fire , 2007 .

[22]  Miran Saje,et al.  Numerical modelling of behaviour of reinforced concrete columns in fire and comparison with Eurocode 2 , 2005 .