Injection Locking in Coupled Core Fluxgate Magnetometers: Exploiting Nonlinearity to Enhance Sensitivity to Weak, Low Frequency, Target Magnetic Fields

The coupled core fluxgate magnetometer (CCFG) is a nonlinear dynamic system that is underpinned by three wound ferromagnetic cores (with primary and secondary windings) electrically coupled in a unidirectional ring configuration. This device exhibits a transition to highly complex behavior when a control parameter is swept through a critical value. The oscillation frequency of CCFG is very sensitive to small changes in the external (i.e., ambient) magnetic field, e.g., those introduced by a target magnetic signal. The CCFG is known to perform quite well in the case of dc target signals. To improve the detection of ac targets, we apply the idea of injection locking (IL) to the CCFG, with a view to lowering the sensor noise-floor at low frequencies where many magnetic target signals of interest are located. An extensive simulation and experimental investigation has been performed; it shows a distinct benefit from the standpoint of reducing the noise-floor in the lower frequency range and therefore enhancing the detectability of a low frequency target magnetic signal which might, otherwise, be buried in the noise. In addition, an interesting variant of conventional IL is presented here; it affords the possibility of even better noise-floor reduction.

[1]  R. Lang,et al.  Injection locking properties of a semiconductor laser , 1982 .

[2]  Bruno Ando,et al.  Exploiting Nonlinear Dynamics in Novel Measurement Strategies and Devices: From Theory to Experiments and Applications , 2011, IEEE Transactions on Instrumentation and Measurement.

[3]  Juan Torres,et al.  Injection locking near a stochastic bifurcation: The dc SQUID as a case study , 2003 .

[4]  L. J. Paciorek Injection locking of oscillators , 1965 .

[5]  Juan P. Torres Emergent oscillations in unidirectionally coupled overdamped bistable systems , 2004 .

[6]  Wiesenfeld,et al.  Noise tolerance of frequency-locked dynamics. , 1987, Physical review. B, Condensed matter.

[7]  William D. Hunt,et al.  A new method for wideband characterization of resonator-based sensing platforms. , 2011, The Review of scientific instruments.

[8]  Visarath In,et al.  Coupled-core fluxgate magnetometer: Novel configuration scheme and the effects of a noise-contaminated external signal , 2007 .

[9]  Bruno Ando,et al.  Design and characterization of a microwire fluxgate magnetometer , 2009 .

[10]  A.J. Seeds,et al.  Millimeter-wave modulated optical signal generation with high spectral purity and wide-locking bandwidth using a fiber-integrated optical injection phase-lock loop , 2000, IEEE Photonics Technology Letters.

[11]  M. J. Feldman,et al.  Parametric amplification by unbiased Josephson junctions , 1975 .

[12]  Sherwin,et al.  Complete charge density-wave mode locking and freeze-out of fluctuations in NbSe3. , 1985, Physical review. B, Condensed matter.

[13]  Sang Eon Park,et al.  Production of raman laser beams using injection-locking technique , 2002, CPEM 2002.

[14]  Luc Thévenaz,et al.  Novel schemes for optical signal generation using laser injection locking with application to Brillouin sensing , 2004 .

[15]  Kurt Wiesenfeld,et al.  Suppression of period doubling in the dynamics of a bouncing ball , 1987 .

[16]  Frequency-sweep generation by resonant self-injection locking. , 1999, Optics letters.

[17]  Pavel Ripka,et al.  Magnetic sensors and magnetometers , 2002 .

[18]  Wiesenfeld,et al.  Observation of induced subcritical bifurcation by near-resonant perturbations. , 1994, Physical review letters.

[19]  C. Trigona,et al.  Injection-locking benefits for weak AC magnetic field detection in Coupled-Core Fluxgate Magnetometers , 2012, 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[20]  M. Cross,et al.  The amplitude equation near the convective threshold: application to time-dependent heating experiments , 1981, Journal of Fluid Mechanics.

[21]  M. J. Deen,et al.  A Fully Integrated CMOS Power Amplifier Using Superharmonic Injection-Locking for Short-Range Applications , 2011, IEEE Sensors Journal.

[22]  Experimental test of the normal form for period doubling bifurcations , 1995 .

[23]  A R Bulsara,et al.  Stochastic dynamics in a two-dimensional oscillator near a saddle-node bifurcation. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[24]  Brun,et al.  Period-doubling lasers as small-signal detectors. , 1985, Physical review letters.

[25]  Luc Thévenaz,et al.  Novel measurement scheme for injection-locking experiments , 1999 .

[26]  William A. Geyger Nonlinear-magnetic control devices , 1964 .