Design and fabrication of custom-made dental implants

Dental implant has been attracting more and more attention due to their advantages of reliability and comfort. It is estimated that 10% of people will need dental implants in their life time. Especially, companies offer a system for customer to choice. But, no one research on custom-made dental implants. Traditional implants have their limitation and they are not better fit due to the difference of patient’s oral condition. The advantages of custom implant are accuracy fit and esthetic emergence profile. So, custom-made implant is desirable. Another key problem of custom-made dental implant is manufacturing. Dental implant is difficult to machine due to its complex features and its material (titanium). With the ever increasing demand for tight tolerance and increased complexity and accuracy, traditional machine tools have become ineffective for machining them. So, we design and built a PC-based CNC Turn-Mill-Hob professional machining center for machining our custom-made dental implants accurately and efficiently. This paper introduces our method: firstly, the custom-made dental implant in various oral conditions is designed by using our implant database. And then, FEA results indicate the stress distribution and magnitude of implant-bone interface for dentist referring. Finally, samples are automatic machined by our machining center.

[1]  Franchi Marco,et al.  Peri-implant osteogenesis in health and osteoporosis. , 2005, Micron.

[2]  Ilser Turkyilmaz,et al.  Influence of bone density on implant stability parameters and implant success: a retrospective clinical study , 2008, BMC oral health.

[3]  B. Johanson,et al.  INTRA-OSSEOUS ANCHORAGE OF DENTAL PROSTHESES , 1970 .

[4]  S. Hansson,et al.  The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. , 2003, Journal of biomechanics.

[5]  F. Mante,et al.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. , 1998, The Journal of oral implantology.

[6]  P. Branemark,et al.  Intra-Osseous Anchorage of Dental Prostheses , 1970, Scandinavian Journal of Plastic and Reconstructive Surgery.

[7]  Jörgen Lindström,et al.  Intra-osseous anchorage of dental prostheses. I. Experimental studies , 1971 .

[8]  B Rangert,et al.  Influence of implant diameters on the integration of screw implants. An experimental study in rabbits. , 1997, International journal of oral and maxillofacial surgery.

[9]  Steven E Eckert,et al.  Survey of implant experience by prosthodontists in the United States. , 2002, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[10]  Robert F Wright,et al.  Effect of implant size and shape on implant success rates: a literature review. , 2005, The Journal of prosthetic dentistry.

[11]  M. C. Shaw Metal Cutting Principles , 1960 .

[12]  Tao Li,et al.  Optimal design of thread height and width on an immediately loaded cylinder implant: A finite element analysis , 2010, Comput. Biol. Medicine.

[13]  J. Hirsch,et al.  Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. , 1998, European journal of oral sciences.

[14]  P. J. Reucroft,et al.  Mechanical properties of environmental-electro-discharge-sintered porous Ti implants , 2005 .

[15]  Gabor Tepper,et al.  A 5-year prospective multicenter study on 1-stage smooth-surface Brånemark System implants with early loading in edentulous mandibles. , 2008, The International journal of oral & maxillofacial implants.

[16]  P I Brånemark,et al.  Intra-osseous anchorage of dental prostheses. II. Review of clinical approaches. , 1972, Scandinavian journal of plastic and reconstructive surgery.

[17]  R Z LeGeros,et al.  Three‐Dimensional Finite Element Analyses of Four Designs of a High‐Strength Silicon Nitride Implant , 2000, Implant dentistry.

[18]  Ming-Jyi Jang,et al.  Modeling and high-precision control of a ball-screw-driven stage , 2004 .

[19]  D Buser,et al.  Persistent Acute Inflammation at the Implant-Abutment Interface , 2003, Journal of dental research.

[20]  P P Binon,et al.  Implants and components: entering the new millennium. , 2000, The International journal of oral & maxillofacial implants.

[21]  Reymond Clavel,et al.  Issues in precision motion control and microhandling , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[22]  S Winkler,et al.  The influence of implant type, material, coating, diameter, and length on periotest values at second-stage surgery: DICRG interim report no. 4. Dental Implant Clinical Research Group. , 1994, Implant dentistry.

[23]  Emre Tezulas,et al.  Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone. , 2008, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[24]  Rui Hou,et al.  Bivariate evaluation of cylinder implant diameter and length: a three-dimensional finite element analysis. , 2008, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[25]  Hirohiko Suwa,et al.  Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study. , 2005, Bone.

[26]  C. Misch Contemporary Implant Dentistry , 1993 .

[27]  P Missika,et al.  Optimal implant stabilization in low density bone. , 2001, Clinical oral implants research.

[28]  Nobuyuki Matsui,et al.  GMDH-based modeling and feedforward compensation for nonlinear friction in table drive systems , 2003, IEEE Trans. Ind. Electron..

[29]  Zhou Lei [Progress of dental implantology]. , 2009, Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology.