Study on heat transfer characteristics of the high temperature reheater tube panel in a 300 MW CFB boiler with fluidized bed heat exchanger

Abstract On the basis of measurements on the fluidized bed heat exchanger (FBHE) of a 300 MW lean-coal-fired circulating fluidized bed (CFB) boiler under different thermal loads and numerical calculation for steam mass flow rate distribution inside the high temperature reheater (HTR) tube panels, the ash-side heat transfer coefficient distribution along the ash movement direction inside the FBHE was obtained in this paper. A cell model with energy and material balances was also developed for the FBHE. The measured and calculated results indicate that the post-combustion phenomenon exists in the FBHE. The ash-flow movement inside the FBHE has an important impact on the bed-to-tube heat transferring process. Specifically, along the ash moving direction, steam temperature at the outlet of corresponding tube panel decreases gradually, as well as the local ash-side heat transfer coefficient. These results can provide referential materials for design and operation of the FBHE in large-scale CFB boilers.

[1]  Song-Charng Kong,et al.  Development of a generalized numerical framework for simulating biomass fast pyrolysis in fluidize , 2013 .

[2]  Q. Lu,et al.  The thermal-hydraulic calculation and analysis of the medium temperature platen superheater in a 300 MWe CFB boiler , 2013 .

[3]  Junye Wang,et al.  Theory of flow distribution in manifolds , 2011 .

[4]  Zheng Li,et al.  Design Theory of Circulating Fluidized Bed Boilers , 2005 .

[5]  Qinhui Wang,et al.  Development of a new external heat exchanger for a circulating fluidized bed boiler , 2003 .

[6]  David Pallarès,et al.  The role of external heat exchangers in oxy-fuel circulating fluidized bed , 2012 .

[7]  E. Paterson,et al.  OpenFOAM for computational fluid dynamics , 2014 .

[8]  N. P. Kikas Laminar flow distribution in solar systems , 1995 .

[9]  E. N. Sieder,et al.  Heat Transfer and Pressure Drop of Liquids in Tubes , 1936 .

[10]  Zhong Li,et al.  Investigation on Heat Transfer Performance of External Heat Exchanger for Circulating Fluidized Bed Boiler , 2013 .

[11]  Xiaofeng Lu,et al.  Gas–solid flow in an integrated external heat exchanger for CFB boiler , 2010 .

[12]  Honghao He,et al.  Calculation and analysis of dissipation heat loss in large-scale circulating fluidized bed boilers , 2010 .

[13]  W. K. Anderson,et al.  Sensitivity analysis for solid oxide fuel cells using a three-dimensional numerical model , 2009 .

[14]  Hu Chang-hu Wear Proof Technology for EHE Heating Surfaces and Its Application , 2013 .

[15]  Guoliang Song,et al.  Heat transfer characteristics of fluidized bed heat exchanger in a 300 MW CFB boiler , 2012 .

[16]  Sun Yunkai Operation Characteristics of Fluidized Bed Heat Exchanger of Large-scale Circulating Fluidized Bed Boiler , 2012 .

[17]  Guangxi Yue,et al.  Latest Development of CFB Boilers in China , 2009 .

[18]  Waldir Antonio Bizzo,et al.  Heat recovery from hot solid particles in a shallow fluidized bed , 2002 .

[19]  Wei Ge,et al.  SPH method for two-fluid modeling of particle–fluid fluidization , 2011 .

[20]  Jianbo Li,et al.  Development on a small scale industrial CFB boiler with an evaporating loop seal , 2012 .

[21]  Mattias Gustavsson,et al.  Numerical simulation of fluid dynamics in fluidized beds with horizontal heat exchanger tubes , 2000 .

[22]  Masoud Arablu,et al.  Using CFD to Study Combustion and Steam Flow Distribution Effects on Reheater Tubes Operation , 2011 .

[23]  Honghao He,et al.  Combustion Characteristics of the External Circulation Loop on Baima’s 300 MWe Circulating Fluidized Bed Boiler , 2011 .