Self–Actuating SMA–HPFRC Fuses for Auto–Adaptive Composite Structures

Existing experimental results clearly demonstrate that the structural use of conventional, that is, "passive, " high-performance fiber reinforced concretes (HPFRCs) results in excellent seismic performance. By combining shape memory alloy (SMA) fibers with conventional HPFRCs, self-actuating HPFRCs were recently developed. This paper explores a novel way of using such self-actuating SMA-based HPFRCs to develop more seismically resistant and cost-effective, auto-adaptive frame buildings. A numerical investigation on the use of self-actuating HPFRCs in highly energy absorbing, replaceable, "fuse" zones is presented first. Resulting SMA-HPFRC "fuses" can adjust their response to the level of seismic overload. A brief discussion of the possible use of such self-actuating "fuses" in auto-adaptive structures is also provided. While in an actual auto-adaptive structure "triggering" of the desired self-actuating HPFRC fuse behavior will require the use of "sensing" and control elements, this paper focuses only on the behavior of SMA HPFRC fuses and their effect on the overall structural response.

[1]  Antoine E. Naaman,et al.  SELF-STRESSING FIBER COMPOSITES , 2000 .

[2]  Z. Chen,et al.  Formulation and computational aspects of plasticity and damage models with application to quasi-brittle materials , 1995 .

[3]  Jack R. Hayes,et al.  Structural damping with shape-memory alloys: one class of devices , 1995, Smart Structures.

[4]  E. J. Graesser,et al.  Shape‐Memory Alloys as New Materials for Aseismic Isolation , 1991 .

[5]  Neven Krstulovic-Opara,et al.  Active Confinement of Concrete Members with Self-Stressing Composites , 2000 .

[6]  Mohsen Shahinpoor,et al.  Design, prototyping and computer simulations of a novel large bending actuator made with a shape memory alloy contractile wire , 1997 .

[7]  Rosa Maria Vasconez Behavior of fiber-reinforced concrete connections for precast frames under reversed cyclic loading. , 1997 .

[8]  Arup K. Maji,et al.  Smart Prestressing with Shape-Memory Alloy , 1998 .

[9]  T. W. Duerig,et al.  The Mechanical Aspects of Constrained Recovery , 1990 .

[10]  Michael D. Kotsovos,et al.  Effect of vertical prestressing on the punching failure , 1993 .

[11]  F. Veldpaus,et al.  Application of computed phase transformation power to control shape memory alloy actuators , 1997 .

[12]  James Michael LaFave,et al.  Seismic Retrofit with Discontinuous Slurry Infiltrated Mat Concrete (SIMCON) Jackets , 2000, SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit.

[13]  Satrajit Das,et al.  Seismic Design of Vertically Irregular Reinforced Concrete Structures , 2000 .

[14]  Andrew S. Whittaker,et al.  Testing of Passive Energy Dissipation Systems , 1993 .

[15]  Sir A Harris,et al.  AXIALLY LOADED CONCRETE COLUMNS WITH NON-UNIFORM LATERAL CONFINEMENT , 1987 .

[16]  N. J. Gardner,et al.  Laterally Prestressed Eccentrically Loaded Slender Columns , 1992 .

[17]  C. Liang,et al.  Structural modification of simply-supported laminated plates using embedded shape memory alloy fibers , 1991 .

[18]  S H Perry,et al.  Concrete columns with lateral prestressing , 1991 .

[19]  Neven Krstulovic-Opara,et al.  Tensile behavior of slurry infiltrated mat concrete (SIMCON) , 1997 .

[20]  James M. Kelly,et al.  Experimental and analytical studies of shape-memory alloy dampers for structural control , 1995, Smart Structures.

[21]  Antoine E. Naaman,et al.  Fiber Reinforced Concrete Joints for Precast Construction in Seismic Areas , 1991 .

[22]  Paolo Gardoni,et al.  Seismic response of base-isolated structures with shape memory alloy damping devices , 1997, Smart Structures.

[23]  Tom Borden,et al.  Shape Memory Alloy Fastener Rings , 1990 .

[24]  Madhusudan Khuntia Behavior of fiber-reinforced concrete-encased open web steel joist composite members under monotonic and reversed cyclic loading. , 1998 .