Large-area 97-μm pitch indirect-detection active-matrix flat-panel imager (AMFPI)

The development of the highest resolution, large-area, active- matrix, flat-panel, imager (AMFPI) thus far reported is described. This imager is based on a 97 micrometer pixel pitch array with each pixel comprising a single a-Si:H TFT coupled to a discrete a-Si:H n-i-p photodiode. While the initial configuration chosen for fabrication is a 2048 X 2048 pixel array, a larger monolithic array format of 3072 X 4096 pixels is also permitted by the design. When coupled to an overlying scintillator such as a phosphor screen or CsI:Tl, the array allows indirect detection of incident radiation. The array is operated in conjunction with a recently completed electronic acquisition system featuring asynchronous operation, a large addressing range, fast analog signal extraction and digitization, and 16-bit digitization. This imager, whose empirical characterization will be reported in a subsequent paper, was developed as an engineering prototype to allow investigation of the performance limits of the most aggressive array designs permitted by present active-matrix technology. The development of this new imager builds upon knowledge acquired from the iterative design, fabrication, and quantitative evaluation of earlier engineering prototypes based on a series of 127 micrometer pitch arrays. This paper summarizes the general program of research leading to this new device and puts this in the context of world-wide developments in indirect and direct detection AMFPI technology. Some limitations of present AMFPI technology are described, and possible solutions are discussed. Specifically, the incorporation of multiplexers based on poly-crystalline silicon circuitry into the array design, to facilitate very high resolution imagers, are proposed. In addition, strategies to significantly improve AMFPI performance at very low exposures, such as those commonly encountered in fluoroscopy, involving the reduction of additive noise (such as through lower preamplifier noise) and the enhancement of system gain (such as through the use of lead iodide) are discussed and initial calculations illustrating potential levels of performance are presented.

[1]  Manabu Tanaka,et al.  Development of a selenium-based flat-panel detector for real-time radiography and fluoroscopy , 1998, Medical Imaging.

[2]  Weidong Huang,et al.  A data acquisition system for flat-panel imaging arrays , 1993 .

[3]  Larry E. Antonuk,et al.  High-resolution, high-frame-rate, flat-panel TFT array for digital x-ray imaging , 1994, Medical Imaging.

[4]  Larry E. Antonuk,et al.  Development of thin-film flat-panel arrays for diagnostic and radiotherapy imaging , 1992, Medical Imaging.

[5]  Jeffrey H. Siewerdsen,et al.  DQE and system optimization for indirect-detection flat-panel imagers in diagnostic radiology , 1998, Medical Imaging.

[6]  P. K. Callagher Amorphous silicon arrays promise large-area imagers , 1995 .

[7]  Larry E. Antonuk,et al.  Signal, noise, and readout considerations in the development of amorphous silicon photodiode arrays for radiotherapy and diagnostic x-ray imaging , 1991, Medical Imaging.

[8]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[9]  Thierry Ducourant,et al.  New CsI/a-Si 17" x 17" x-ray flat-panel detector provides superior detectivity and immediate direct digital output for general radiography systems , 1998, Medical Imaging.

[10]  J Yorkston,et al.  Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager. , 1996, International journal of radiation oncology, biology, physics.

[11]  J Yorkston,et al.  Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation. , 1997, Medical physics.

[12]  I. Blevis,et al.  Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. , 1997, Medical physics.

[13]  Denny L. Y. Lee,et al.  New digital detector for projection radiography , 1995, Medical Imaging.

[14]  Kanai S. Shah,et al.  Characterization of X-Ray Imaging Properties of PbI 2 Films , 1997 .

[15]  Muneaki Yamaguchi,et al.  Two-Dimensional Contact-Type Image Sensor Using Amorphous Silicon Photo-Transistor , 1992 .

[16]  Larry E. Antonuk,et al.  Large area, flat-panel a-Si:H arrays for x-ray imaging , 1993, Medical Imaging.

[17]  Neil C. Bird,et al.  2D Image Sensing Arrays with NIP Diodes , 1993 .

[18]  Maxwell J. Allen,et al.  Characterization of an amorphous-silicon fluoroscopic imager , 1997, Medical Imaging.

[19]  Norbert Jung,et al.  Technical and clinical results of an experimental flat dynamic (digital) x-ray image detector (FDXD) system with real-time corrections , 1998, Medical Imaging.

[20]  Wei Zhao,et al.  Flat panel detector for digital radiology using active matrix readout of amorphous selenium , 1996, Medical Imaging.

[21]  Youming Li,et al.  Amorphous silicon image sensor for x-ray applications , 1995, Electronic Imaging.

[22]  Larry E. Antonuk,et al.  Development of a high-resolution active-matrix flat-panel imager with enhanced fill factor , 1997, Medical Imaging.

[23]  J. R. Hughes,et al.  Amorphous Silicon Image Sensor Arrays , 1992 .

[24]  Larry E. Antonuk,et al.  Large-area flat-panel amorphous silicon imagers , 1995, Medical Imaging.

[25]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[26]  J Yorkston,et al.  Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. , 1992, Medical physics.

[27]  Youming Li,et al.  High-resolution amorphous silicon image sensor , 1996, Medical Imaging.

[28]  Robert A. Street,et al.  Large-area x-ray image sensing using a Pbl2 photoconductor , 1998, Medical Imaging.

[29]  Richard L. Weisfield,et al.  Amorphous Silicon Sensor Arrays for X-Ray and Document Imaging , 1997 .

[30]  Brian G. Rodricks,et al.  Radiographic imaging characteristics of a direct conversion detector using selenium and thin film transistor array , 1997, Medical Imaging.

[31]  Larry E. Antonuk,et al.  Amorphous Silicon Sensor Arrays for Radiation Imaging , 1990 .

[32]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency. , 1997, Medical physics.

[33]  Tatsuya Yamazaki,et al.  Novel large-area MIS-type x-ray image sensor for digital radiography , 1998, Medical Imaging.

[34]  Larry E. Antonuk,et al.  Improved spatial resolution in flat-panel imaging systems , 1998, Medical Imaging.

[35]  Larry E. Antonuk,et al.  Thin-film, flat-panel, composite imagers for projection and tomographic imaging , 1994, IEEE Trans. Medical Imaging.