Importance of k‐space trajectory in echo‐planar myocardial tagging at rest and during dobutamine stress

Hybrid fast gradient echo/echo‐planar imaging (FGRE‐EPI) can be used to increase temporal resolution, enhance tag contrast, and/or decrease scan time for breathhold myocardial tagging. However, off‐resonance effects and motion can lead to local phase discontinuities in FGRE‐EPI raw data when a conventional interleaved bottom‐up k‐space trajectory is used. These discontinuities can be particularly problematic for myocardial tagging, where the image energy is not only concentrated near the k‐space origin, but is also concentrated in multiple spectral peaks centered throughout k‐space. In this study, tag distortion artifacts in FGRE‐EPI tagging due to off‐resonance and velocity‐induced phase discontinuities were characterized at rest and dobutamine stress, and the flyback and gradient moment smoothing (GMS) methods were shown to reduce these artifacts. For the specific parameters used in this study, flyback and GMS resulted in improved image quality at rest and stress, increased myocardium‐tag contrast‐to‐noise ratio (11.4 ± 2.1 vs. 10.0 ± 2.9, P < 0.01 at rest; 11.1 ± 1.8 vs. 8.1 ± 2.4, P < 0.01 at stress), and reduced full width at half maximum of the tag profile (3.6 vs. 3.8 pixels at rest; 4.0 vs. 5.1 pixels at stress) compared to the conventional trajectory. A limitation of the improved trajectory is a parameter‐dependent decrease in data acquisition efficiency. For the specific imaging protocol used, the repetition time of the improved trajectory increased by 36% compared to the conventional trajectory. Magn Reson Med 50:813–820, 2003. © 2003 Wiley‐Liss, Inc.

[1]  L W Hedlund,et al.  Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging. , 1987, Investigative radiology.

[2]  E. Zerhouni,et al.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion. , 1988, Radiology.

[3]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[4]  Robert Turner,et al.  Echo‐planar imaging with asymmetric gradient modulation and inner‐volume excitation , 1990, Magnetic resonance in medicine.

[5]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[6]  O. Simonetti,et al.  Theoretical aspects of motion sensitivity and compensation in echo‐planar imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[7]  D. Noll,et al.  Homodyne detection in magnetic resonance imaging. , 1991, IEEE transactions on medical imaging.

[8]  Koichi Oshio,et al.  Gradient-echo shifting in fast MRI techniques (ERASE imaging) for correction of field inhomogeneity errors and chemical shift , 1992 .

[9]  Kim Butts,et al.  Analysis of flow effects in echo‐planar imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[10]  E. McVeigh,et al.  Cardiac Tagging with Breath‐Hold Cine MRI , 1992, Magnetic resonance in medicine.

[11]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[12]  D G Nishimura,et al.  A Velocity k‐Space Analysis of Flow Effects in Echo‐Planar and Spiral Imaging , 1995, Magnetic resonance in medicine.

[13]  E. McVeigh,et al.  Multi‐Shot EPI for Improvement of Myocardial Tag Contrast: Comparison with Segmented SPGR , 1995, Magnetic resonance in medicine.

[14]  J R Brookeman,et al.  Off‐resonance image artifacts in interleaved‐EPI and GRASE pulse sequences , 1996, Magnetic resonance in medicine.

[15]  E. McVeigh MRI of myocardial function: motion tracking techniques. , 1996, Magnetic resonance imaging.

[16]  John M. Pauly,et al.  Reducing flow artifacts in echo‐planar imaging , 1997, Magnetic resonance in medicine.

[17]  S J Riederer,et al.  Gradient moment smoothing: A new flow compensation technique for multi‐shot echo‐planar imaging , 1997, Magnetic resonance in medicine.

[18]  E R McVeigh,et al.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T , 1998, Magnetic resonance in medicine.

[19]  F. Epstein,et al.  Segmented k‐space fast cardiac imaging using an echo‐train readout , 1999, Magnetic resonance in medicine.

[20]  E R McVeigh,et al.  Multi‐echo segmented k‐space imaging: An optimized hybrid sequence for ultrafast cardiac imaging , 1999, Magnetic resonance in medicine.

[21]  P Boesiger,et al.  Toward high‐resolution myocardial tagging , 1999, Magnetic resonance in medicine.

[22]  A E Arai,et al.  Optimization of fast cardiac imaging using an echo‐train readout , 2000, Journal of magnetic resonance imaging : JMRI.

[23]  O. Simonetti,et al.  Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. , 2001, Radiology.

[24]  M. Oudkerk,et al.  Dobutamine Cardiovascular Magnetic Resonance for the Detection of Myocardial Ischemia With the Use of Myocardial Tagging , 2003, Circulation.