Comparison of multivariate linear regression methods in micro‐Raman spectrometric quantitative characterization

Chemical imaging was used in this study as a powerful analytical tool to characterize pharmaceuticals in solid form. The majority of analyses are evaluated with bilinear modelling using only the pure component spectra or just the chemical images themselves to estimate the concentrations in each pixel, which are far from true quantitative determination. Our aim was to create more accurate concentration images using regression methods. For the first time in chemical imaging, variable selections with interval partial least squares (PLS) and with genetic algorithms (PLS-GA) were applied to increase the efficiency of the models. These were compared to numerous bilinear modelling and multivariate linear regression methods such as univariate regression, classical least squares (CLS), multivariate curve resolution-alternating least squares (MCR-ALS), principal component regression (PCR) and partial least squares (PLS). Two component spray-dried pharmaceuticals were used as a model. The paper is shown that, in contrast to the usual way of using either external validation or cross-validation, both should be performed simultaneously in order to get a clear picture of the prediction errors and to be able to select the appropriate models. Using PLS with variable selection, the root mean square errors were reduced to 3% per pixel by keeping only those peaks that are truly necessary for the estimation of concentrations. It is also shown that interval PLS can point out the best peak for univariate regression, and can thereby be of great help even when regulations allow only univariate models for product quality testing. Variable selection, besides yielding more accurate overall concentrations across a Raman map, also reduces the deviation among pixel concentrations within the images, thereby increasing the sensitivity of homogeneity studies. Copyright (c) 2015 John Wiley & Sons, Ltd.

[1]  H. Pataki,et al.  Testing the performance of pure spectrum resolution from Raman hyperspectral images of differently manufactured pharmaceutical tablets. , 2012, Analytica chimica acta.

[2]  H. Pataki,et al.  Characterization of drug-cyclodextrin formulations using Raman mapping and multivariate curve resolution. , 2011, Journal of pharmaceutical and biomedical analysis.

[3]  P J Cullen,et al.  Recent applications of Chemical Imaging to pharmaceutical process monitoring and quality control. , 2008, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[4]  Rasmus Bro,et al.  Variable selection in regression—a tutorial , 2010 .

[5]  R. Leardi,et al.  Variable selection for multivariate calibration using a genetic algorithm: prediction of additive concentrations in polymer films from Fourier transform-infrared spectral data , 2002 .

[6]  José Manuel Amigo,et al.  Direct quantification and distribution assessment of major and minor components in pharmaceutical tablets by NIR-chemical imaging. , 2009, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[7]  Romà Tauler,et al.  Multivariate Curve Resolution (MCR) from 2000: Progress in Concepts and Applications , 2006 .

[8]  José Manuel Amigo,et al.  Practical issues of hyperspectral imaging analysis of solid dosage forms , 2010, Analytical and bioanalytical chemistry.

[9]  R. Bro,et al.  Near-infrared chemical imaging (NIR-CI) on pharmaceutical solid dosage forms-comparing common calibration approaches. , 2008, Journal of pharmaceutical and biomedical analysis.

[10]  R. Poppi,et al.  Analysis of pharmaceutical pellets: an approach using near-infrared chemical imaging. , 2011, Analytica chimica acta.

[11]  N. Etxebarria,et al.  Quantitative analysis of essential oils from rosemary in virgin olive oil using Raman spectroscopy and chemometrics , 2012 .

[12]  Keith C Gordon,et al.  Raman mapping of pharmaceuticals. , 2011, International journal of pharmaceutics.

[13]  Romà Tauler,et al.  Local rank analysis for exploratory spectroscopic image analysis. Fixed Size Image Window-Evolving Factor Analysis , 2005 .

[14]  R. Leardi Genetic algorithms in chemometrics and chemistry: a review , 2001 .

[15]  Slobodan Sasić,et al.  An In-Depth Analysis of Raman and Near-Infrared Chemical Images of Common Pharmaceutical Tablets , 2007, Applied spectroscopy.

[16]  George Papandreou,et al.  Multivariate analysis applied to the study of spatial distributions found in drug-eluting stent coatings by confocal Raman microscopy. , 2008, Analytical chemistry.

[17]  Marcel Maeder,et al.  Use of local rank‐based spatial information for resolution of spectroscopic images , 2008 .

[18]  J. I. J. Rozo,et al.  Complementary near-infrared and Raman chemical imaging of pharmaceutical thin films. , 2011, Journal of pharmaceutical sciences.

[19]  Susumu Hasegawa,et al.  Evaluation of solid dispersions on a molecular level by the Raman mapping technique. , 2008, International journal of pharmaceutics.

[20]  M. Blanco,et al.  Content uniformity studies in tablets by NIR-CI. , 2011, Journal of pharmaceutical and biomedical analysis.

[21]  Wolfgang Schrof,et al.  Confocal Raman-Spectroscopy: Analytical Approach to Solid Dispersions and Mapping of Drugs , 1999, Pharmaceutical Research.

[22]  Wim Jiskoot,et al.  Near-Infrared Imaging for Studying Homogeneity of Protein-Sugar Mixtures , 2006, Pharmaceutical Research.

[23]  Cyril Ruckebusch,et al.  Multivariate Curve Resolution Methods in Imaging Spectroscopy: Influence of Extraction Methods and Instrumental Perturbations , 2003, J. Chem. Inf. Comput. Sci..

[24]  E. Widjaja,et al.  Application of Raman microscopy and band-target entropy minimization to identify minor components in model pharmaceutical tablets. , 2008, Journal of pharmaceutical and biomedical analysis.

[25]  C. Gendrin,et al.  Content uniformity of pharmaceutical solid dosage forms by near infrared hyperspectral imaging: A feasibility study. , 2007, Talanta.

[26]  Marc Garland,et al.  Detailed spectroscopic analysis of complex multi‐component materials using a combination of Raman mapping with BTEM , 2012 .

[27]  C. Gendrin,et al.  Pharmaceutical applications of vibrational chemical imaging and chemometrics: a review. , 2008, Journal of pharmaceutical and biomedical analysis.

[28]  G. Marosi,et al.  Raman microscopic evaluation of technology dependent structural differences in tablets containing imipramine model drug. , 2010, Journal of pharmaceutical and biomedical analysis.

[29]  D. Bikiaris,et al.  Combining SEM, TEM, and micro-Raman techniques to differentiate between the amorphous molecular level dispersions and nanodispersions of a poorly water-soluble drug within a polymer matrix. , 2007, International journal of pharmaceutics.

[30]  R. Leardi,et al.  Genetic algorithms applied to feature selection in PLS regression: how and when to use them , 1998 .

[31]  José Manuel Amigo,et al.  A comparison of a common approach to partial least squares-discriminant analysis and classical least squares in hyperspectral imaging. , 2009, International journal of pharmaceutics.

[32]  Cyril Ruckebusch,et al.  Characterisation of heavy oils using near-infrared spectroscopy: optimisation of pre-processing methods and variable selection. , 2011, Analytica chimica acta.

[33]  M. Strlič,et al.  Classification of iron‐based inks by means of micro‐Raman spectroscopy and multivariate data analysis , 2013 .

[34]  R. Tan,et al.  Detection of trace crystallinity in an amorphous system using Raman microscopy and chemometric analysis. , 2011, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[35]  R. Poppi,et al.  NIR imaging spectroscopy for quantification of constituents in polymers thin films loaded with paracetamol. , 2013, Analytica chimica acta.

[36]  G. Marosi,et al.  Comparison of electrospun and extruded Soluplus®-based solid dosage forms of improved dissolution. , 2012, Journal of pharmaceutical sciences.

[37]  Colm P. O'Donnell,et al.  Wavelength Selection for Development of a near Infrared Imaging System for Early Detection of Bruise Damage in Mushrooms (Agaricus Bisporus) , 2012 .

[38]  José Manuel Amigo,et al.  Nir-chemical imaging study of acetylsalicylic acid in commercial tablets. , 2009, Talanta.

[39]  B. Kowalski,et al.  Partial least-squares regression: a tutorial , 1986 .

[40]  Griselda Polla,et al.  Characterization of semi-solid Self-Emulsifying Drug Delivery Systems (SEDDS) of atorvastatin calcium by Raman image spectroscopy and chemometrics. , 2013, Journal of pharmaceutical and biomedical analysis.

[41]  G. Marosi,et al.  Comparison of chemometric methods in the analysis of pharmaceuticals with hyperspectral Raman imaging , 2011 .

[42]  Jia Duan,et al.  Near-infrared spectral imaging for quantitative analysis of active component in counterfeit imidacloprid using PLS regression , 2013 .

[43]  H. Pataki,et al.  Characterization of melt extruded and conventional Isoptin formulations using Raman chemical imaging and chemometrics. , 2011, International journal of pharmaceutics.

[44]  Ronei J. Poppi,et al.  Quantitative analysis of piroxicam polymorphs pharmaceutical mixtures by hyperspectral imaging and chemometrics , 2011 .

[45]  B. Igne,et al.  Effects and detection of raw material variability on the performance of near-infrared calibration models for pharmaceutical products. , 2014, Journal of pharmaceutical sciences.

[46]  B. Vajna,et al.  Analysis of car shredder polymer waste with Raman mapping and chemometrics , 2012 .

[47]  Zou Xiaobo,et al.  Variables selection methods in near-infrared spectroscopy. , 2010, Analytica chimica acta.

[48]  Christophe Collet,et al.  Self-Modelling Curve Resolution of near Infrared Imaging Data , 2008 .

[49]  L. Buhse,et al.  Quality assessment of internet pharmaceutical products using traditional and non-traditional analytical techniques. , 2005, International journal of pharmaceutics.

[50]  R. Tauler,et al.  Application of multivariate curve resolution alternating least squares (MCR-ALS) to the quantitative analysis of pharmaceutical and agricultural samples. , 2008, Talanta.

[51]  M. Khan,et al.  Risperidone solid dispersion for orally disintegrating tablet: its formulation design and non-destructive methods of evaluation. , 2010, International journal of pharmaceutics.

[52]  J. Fages,et al.  Use of supercritical CO2‐aided and conventional melt extrusion for enhancing the dissolution rate of an active pharmaceutical ingredient , 2012 .

[53]  S. Šašiċ,et al.  Raman chemical mapping of low-content active pharmaceutical ingredient formulations. III. Statistically optimized sampling and detection of polymorphic forms in tablets on stability. , 2012, Analytical chemistry.

[54]  Raman Mapping of Low-Content Active-Ingredient Pharmaceutical Formulations. Part II: Statistically Optimized Sampling for Detection of Less Than 1% of an Active Pharmaceutical Ingredient , 2008, Applied spectroscopy.

[55]  P. Geladi,et al.  Hyperspectral NIR imaging for calibration and prediction: a comparison between image and spectrometer data for studying organic and biological samples. , 2006, The Analyst.

[56]  J C Menezes,et al.  A multivariate approach for the statistical evaluation of near-infrared chemical images using Symmetry Parameter Image Analysis (SPIA). , 2011, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[57]  S. Šašiċ,et al.  Raman Mapping of Low-Content API Pharmaceutical Formulations. I. Mapping of Alprazolam in Alprazolam/Xanax Tablets , 2006, Pharmaceutical Research.

[58]  C. B. Lucasius,et al.  Genetic algorithms in wavelength selection: a comparative study , 1994 .

[59]  Clive J Roberts,et al.  Elucidation of the internal physical and chemical microstructure of pharmaceutical granules using X-ray micro-computed tomography, Raman microscopy and infrared spectroscopy. , 2010, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.