Evaluation of the Anterior Segment Angle-to-Angle Scan of Cirrus High-Definition Optical Coherence Tomography and Comparison With Gonioscopy and With the Visante OCT.

Purpose To evaluate the diagnostic performance of the anterior segment angle-to-angle scan of the Cirrus high-definition optical coherence tomography (HD-OCT) in detecting eyes with closed angles. Methods All subjects underwent dark-room gonioscopy by an ophthalmologist. A technician performed anterior segment imaging with Cirrus (n = 202) and Visante OCT (n = 85) under dark-room conditions. All eyes were categorized by two masked graders as per number of closed quadrants. Each quadrant of anterior chamber angle was categorized as a closed angle if posterior trabecular meshwork could not be seen on gonioscopy or if there was any irido-corneal contact anterior to scleral spur in Cirrus and Visante images. An eye was graded as having a closed angle if two or more quadrants were closed. Agreement and area under the curve (AUC) were performed. Results There were 50 (24.8%) eyes with closed angles. The agreements of closed-angle diagnosis (by eye) between Cirrus HD-OCT and gonioscopy (k = 0.59; 95% confidence interval (CI) 0.45-0.72; AC1 = 0.76) and between Cirrus and Visante OCT (k = 0.65; 95% CI 0.48-0.82, AC1 = 0.77) were moderate. The AUC for diagnosing the eye with gonioscopic closed angle by Cirrus HD-OCT was good (AUC = 0.86; sensitivity = 83.33; specificity = 77.78). The diagnostic performance of Cirrus HD-OCT in detecting the eyes with closed angles was similar to that of Visante (AUC 0.87 vs. 0.9, respectively; P = 0.51). Conclusions The anterior segment angle-to-angle scans of Cirrus HD-OCT demonstrated similar diagnostic performance as Visante in detecting gonioscopic closed angles. The agreement between Cirrus and gonioscopy for detecting eyes with closed angles was moderate.

[1]  E. DeLong,et al.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. , 1988, Biometrics.

[2]  Tin Aung,et al.  Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment. , 2012, Investigative ophthalmology & visual science.

[3]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[4]  Neha Chaturvedi,et al.  Application of anterior segment optical coherence tomography in glaucoma. , 2014, Survey of ophthalmology.

[5]  D. Machin,et al.  The prevalence of glaucoma in Chinese residents of Singapore: a cross-sectional population survey of the Tanjong Pagar district. , 2000, Archives of ophthalmology.

[6]  Mingguang He,et al.  Anterior chamber angle assessment techniques. , 2008, Survey of ophthalmology.

[7]  Joel S Schuman,et al.  Spectral domain optical coherence tomography for glaucoma (an AOS thesis). , 2008, Transactions of the American Ophthalmological Society.

[8]  P. Foster The epidemiology of primary angle closure and associated glaucomatous optic neuropathy , 2002, Seminars in ophthalmology.

[9]  R. Ritch,et al.  Quantitative evaluation of anterior segment parameters in the era of imaging. , 2007, Transactions of the American Ophthalmological Society.

[10]  J. Fujimoto,et al.  Optical biopsy and imaging using optical coherence tomography , 1995, Nature Medicine.

[11]  T. Aung,et al.  Imaging of the iridocorneal angle with the RTVue spectral domain optical coherence tomography. , 2012, Investigative ophthalmology & visual science.

[12]  J. S. Myers Anterior chamber angle imaging with optical coherence tomography , 2012 .

[13]  Tin Aung,et al.  High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. , 2009, Archives of ophthalmology.

[14]  J. Myers,et al.  Comparison of Gonioscopy and Anterior Segment Ocular Coherence Tomography in Detecting Angle Closure in Different Quadrants of the Anterior Chamber Angle , 2009 .

[15]  D. Friedman,et al.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. , 2008, Ophthalmology.

[16]  Y H Chan,et al.  Biostatistics 104: correlational analysis. , 2003, Singapore medical journal.

[17]  D. Friedman,et al.  Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. , 2007, Ophthalmology.

[18]  J. Fujimoto Optical coherence tomography for ultrahigh resolution in vivo imaging , 2003, Nature Biotechnology.

[19]  A. Viera,et al.  Understanding interobserver agreement: the kappa statistic. , 2005, Family medicine.

[20]  P. Schacknow,et al.  The Glaucoma Book A Practical, Evidence-Based Approach to Patient Care , 2010 .

[21]  E. B. Rodrigues,et al.  Anterior Segment Tomography with the Cirrus Optical Coherence Tomography , 2012, Journal of ophthalmology.