Emerging Trends in Heart Valve Engineering: Part III. Novel Technologies for Mitral Valve Repair and Replacement

In this portion of an extensive review of heart valve engineering, we focus on the current and emerging technologies and techniques to repair or replace the mitral valve. We begin with a discussion of the currently available mechanical and bioprosthetic mitral valves followed by the rationale and limitations of current surgical mitral annuloplasty methods; a discussion of the technique of neo-chordae fabrication and implantation; a review the procedures and clinical results for catheter-based mitral leaflet repair; a highlight of the motivation for and limitations of catheter-based annular reduction therapies; and introduce the early generation devices for catheter-based mitral valve replacement.

[1]  S. Solomon,et al.  Treatment of functional mitral regurgitation by percutaneous annuloplasty: results of the TITAN Trial , 2012, European journal of heart failure.

[2]  Alexei Marko,et al.  Transapical mitral implantation of the Tiara bioprosthesis: pre-clinical results. , 2014, JACC: Cardiovascular Interventions.

[3]  M. Schmoeckel,et al.  Impact of failed mitral clipping on subsequent mitral valve operations. , 2014, The Annals of thoracic surgery.

[4]  Scott Lim,et al.  Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. , 2009, Journal of the American College of Cardiology.

[5]  E. Wolner,et al.  The On-X prosthetic heart valve at five years. , 2002, The Annals of thoracic surgery.

[6]  S. Goldberg,et al.  Percutaneous Mitral Annuloplasty for Functional Mitral Regurgitation: Results of the CARILLON Mitral Annuloplasty Device European Union Study , 2009, Circulation.

[7]  Neelakantan Saikrishnan,et al.  Micro Particle Image Velocimetry Measurements of Steady Diastolic Leakage Flow in the Hinge of a St. Jude Medical® Regent™ Mechanical Heart Valve , 2013, Annals of Biomedical Engineering.

[8]  K. Riemslagh,et al.  A Three-dimensional Analysis of Flow in the Pivot Regions of an ATS Bileaflet Valve , 1999, The International journal of artificial organs.

[9]  William A Zoghbi,et al.  Dynamic annular geometry and function in patients with mitral regurgitation: insight from three-dimensional annular tracking. , 2010, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[10]  E. Sowton,et al.  Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve. , 1993, Journal of the American College of Cardiology.

[11]  Samuel Z Goldhaber,et al.  "Bridging" and mechanical heart valves: perils, promises, and predictions. , 2006, Circulation.

[12]  P. Herijgers,et al.  Fifteen-year experience with the mitral Carpentier-Edwards PERIMOUNT pericardial bioprosthesis. , 2001, The Annals of thoracic surgery.

[13]  Lakshmi Prasad Dasi,et al.  Procoagulant Properties of Flow Fields in Stenotic and Expansive Orifices , 2007, Annals of Biomedical Engineering.

[14]  B. Griffin,et al.  Glycosaminoglycan profiles of myxomatous mitral leaflets and chordae parallel the severity of mechanical alterations. , 2003, Journal of the American College of Cardiology.

[15]  John Fisher,et al.  An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics , 1994 .

[16]  Arash Kheradvar Development and Testing a Dynamic Bi-leaflet Mitral Prosthesis , 2009 .

[17]  Denis Bouchard,et al.  Fifteen years of clinical and echocardiographic follow up with the carbomedics heart valve. , 2006, The Journal of heart valve disease.

[18]  E. Schwammenthal,et al.  Integrated mechanism for functional mitral regurgitation: leaflet restriction versus coapting force: in vitro studies. , 1996, Circulation.

[19]  Susan Armstrong,et al.  Twenty-year results of the Hancock II bioprosthesis. , 2006, The Journal of heart valve disease.

[20]  Wei Yin,et al.  A Biocompatible Flow Chamber to Study the Hemodynamic Performance of Prosthetic Heart Valves , 2012, ASAIO journal.

[21]  U. Steinseifer,et al.  Closing click of St Jude Medical and Duromedics Edwards bileaflet valves: complaints created by valve noise and their relation to sound pressure and hearing level. , 1991, European heart journal.

[22]  Nancy M Albert,et al.  2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, The Journal of thoracic and cardiovascular surgery.

[23]  Uberto Bortolotti,et al.  Mitral valve repair with artificial chordae: a review of its history, technical details, long-term results, and pathology. , 2012, The Annals of thoracic surgery.

[24]  G. Gerosa,et al.  In vitro comparison of different mechanical prostheses suitable for replacement of the systemic atrioventricular valve in children. , 2012, The Journal of thoracic and cardiovascular surgery.

[25]  F. Laborde,et al.  Pericarbon pericardial bioprosthesis: an experience based on the lessons of the past. , 2001, The Annals of thoracic surgery.

[26]  Shmuel Einav,et al.  Design Optimization of a Mechanical Heart Valve for Reducing Valve Thrombogenicity—A Case Study with ATS Valve , 2010, ASAIO journal.

[27]  T. Feldman,et al.  Percutaneous approaches to valve repair for mitral regurgitation. , 2014, Journal of the American College of Cardiology.

[28]  Robert C Gorman,et al.  Ischemic mitral regurgitation: a quantitative three-dimensional echocardiographic analysis. , 2011, The Annals of thoracic surgery.

[29]  Laura Mauri,et al.  The EVEREST II Trial: design and rationale for a randomized study of the evalve mitraclip system compared with mitral valve surgery for mitral regurgitation. , 2010, American heart journal.

[30]  A. Kalangos,et al.  Regarding "The EVEREST II Trial: design and rationale for a randomized study of the Evalve MitraClip system compared with mitral valve surgery for mitral regurgitation". , 2011, American heart journal.

[31]  Arash Kheradvar,et al.  Echocardiographic particle image velocimetry: a novel technique for quantification of left ventricular blood vorticity pattern. , 2010, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[32]  U Althaus,et al.  Early experience with the new Masters series of St. Jude Medical heart valve: in vivo hemodynamic and clinical results in patients with narrowed aortic annulus. , 1997, The Journal of heart valve disease.

[33]  B. Griffin,et al.  Mitral valve prolapse , 2005, The Lancet.

[34]  Arash Kheradvar,et al.  High-speed particle image velocimetry to assess cardiac fluid dynamics in vitro: From performance to validation , 2012 .

[35]  Arash Kheradvar,et al.  The effects of dynamic saddle annulus and leaflet length on transmitral flow pattern and leaflet stress of a bileaflet bioprosthetic mitral valve. , 2012, The Journal of heart valve disease.

[36]  T. Feldman,et al.  Transcatheter mitral valve interventions: current status and future perspective. , 2012, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[37]  P. Pibarot,et al.  Prosthetic Heart Valves Selection of the Optimal Prosthesis and Long-Term Management , 2009 .

[38]  J. Gardin,et al.  Burden of valvular heart diseases: a population-based study , 2006, The Lancet.

[39]  Anja Mueller,et al.  Synthesis of a low thrombogenic heart valve coating with horseradish peroxidase , 2005 .

[40]  R. Levy,et al.  Prevention of bioprosthetic heart valve calcification by ethanol preincubation. Efficacy and mechanisms. , 1997, Circulation.

[41]  Peter Kremer,et al.  Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[42]  Robert W Emery,et al.  Five-year follow up of the ATS mechanical heart valve. , 2004, The Journal of heart valve disease.

[43]  K. Kuck,et al.  Early Insight into Mitralign Direct Annuloplasty for Treatment of Functional Mitral Regurgitation , 2011 .

[44]  Thoralf M Sundt,et al.  2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Circulation.

[45]  Hélène A. Simon,et al.  A Numerical Investigation of Blood Damage in the Hinge Area of Aortic Bileaflet Mechanical Heart Valves During the Leakage Phase , 2012, Annals of Biomedical Engineering.

[46]  Thoralf M Sundt,et al.  2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Journal of the American College of Cardiology.

[47]  T. David Artificial chordae. , 2004, Seminars in thoracic and cardiovascular surgery.

[48]  Peter Johansen,et al.  Are sounds from mechanical heart valves equal for different valve types? , 2008, The Journal of heart valve disease.

[49]  Thierry Bové,et al.  Twenty-year single-center experience with the medtronic open pivot mechanical heart valve. , 2014, The Annals of thoracic surgery.

[50]  G. Gerosa,et al.  Mid-Term Follow-Up in Patients with Biocor Porcine Bioprostheses , 2002, Cardiovascular surgery.

[51]  Robert W Emery,et al.  The initial experience with the ATS Medical mechanical cardiac valve prosthesis. , 2003, The Annals of thoracic surgery.

[52]  David H Adams,et al.  Large annuloplasty rings facilitate mitral valve repair in Barlow's disease. , 2006, The Annals of thoracic surgery.

[53]  Hélène A. Simon,et al.  FLUID MECHANICS OF ARTIFICIAL HEART VALVES , 2009, Clinical and experimental pharmacology & physiology.

[54]  T. Athanasiou,et al.  Outcomes of mitral valve repair using artificial chordae. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[55]  Marcio Forleo,et al.  Effect of Hypertension on the Closing Dynamics and Lagrangian Blood Damage Index Measure of the B-Datum Regurgitant Jet in a Bileaflet Mechanical Heart Valve , 2013, Annals of Biomedical Engineering.

[56]  Timothy J Gardner,et al.  Mitral-valve repair versus replacement for severe ischemic mitral regurgitation. , 2014, The New England journal of medicine.

[57]  E. Verrier,et al.  Valvular Heart Disease : Changing Concepts in Disease Management , 2009 .

[58]  Francesca N. Delling,et al.  Epidemiology and Pathophysiology of Mitral Valve Prolapse: New Insights Into Disease Progression, Genetics, and Molecular Basis , 2014, Circulation.

[59]  V. Babaliaros,et al.  Transcatheter Mitral Valve-in-Valve Therapy. , 2016, Interventional cardiology clinics.

[60]  P. Pibarot,et al.  Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. , 2000, Journal of the American College of Cardiology.

[61]  Thierry Bové,et al.  Fifteen years' single-center experience with the ATS bileaflet valve. , 2009, The Journal of heart valve disease.

[62]  E. Foster,et al.  4-year results of a randomized controlled trial of percutaneous repair versus surgery for mitral regurgitation. , 2013, Journal of the American College of Cardiology.

[63]  Tanya Shipkowitz,et al.  Evaluation technique for bileaflet mechanical valves. , 2002, The Journal of heart valve disease.

[64]  E. DeLong,et al.  Prediction of operative mortality after valve replacement surgery. , 2001, Journal of the American College of Cardiology.

[65]  J. Marshall,et al.  Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. , 1989, Circulation.

[66]  P. Vostanis Mental health of looked after children , 2003 .

[67]  Shmuel Einav,et al.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. , 2010, Journal of biomechanics.

[68]  Gino Gerosa,et al.  The fate of Hancock II porcine valve recipients 25 years after implant. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[69]  L. Badano,et al.  Quantitative analysis of mitral annular geometry and function in healthy volunteers using transthoracic three-dimensional echocardiography. , 2014, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[70]  M. Fishbein,et al.  Tissue characterization and calcification potential of commercial bioprosthetic heart valves. , 2001, The Annals of thoracic surgery.

[71]  Friedrich-Christian Riess,et al.  Hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis up to ten years. , 2007, The Annals of thoracic surgery.