Comparative study of PMSM Drive systems based on current control and direct torque control in flux-weakening control region

This paper examines the control performance of permanent magnet synchronous motor (PMSM) drive systems based on current control and direct torque control (DTC) when flux-weakening control is applied. The control law in the M-T frame, which is used in the DTC, requires only armature resistance, whereas the control law in the d-q frame, which is used in current control, requires many motor parameters for flux-weakening control. The experimental results clarify the influence of parameter variation on the control characteristics of flux-weakening and torque limiting. The DTC-based motor drive system combined with the control laws in the M-T frame has several advantages, including insensitivity to parameter variation, simplicity of calculation, and stable control.

[1]  Toshihiko Noguchi,et al.  A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor , 1986, IEEE Transactions on Industry Applications.

[2]  Lixin Tang,et al.  A novel direct torque controlled interior permanent magnet synchronous machine drive with low ripple in flux and torque and fixed switching frequency , 2004, IEEE Transactions on Power Electronics.

[3]  G. Pellegrino,et al.  Direct Flux Field-Oriented Control of IPM Drives With Variable DC Link in the Field-Weakening Region , 2009, IEEE Transactions on Industry Applications.

[4]  Takayoshi Nakano,et al.  A High-Performance Cycloconverter-Fed Synchronous Machine Drive System , 1984, IEEE Transactions on Industry Applications.

[5]  Longya Xu,et al.  A sensorless direct torque control technique for permanent magnet synchronous motors , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[6]  M. Sanada,et al.  Control Method Suitable for Direct-Torque-Control-Based Motor Drive System Satisfying Voltage and Current Limitations , 2012, IEEE Transactions on Industry Applications.

[7]  Seung-Ki Sul,et al.  Speed control of interior permanent magnet synchronous motor drive for flux weakening operation , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[8]  Saverio Bolognani,et al.  Field-weakening in high-performance PMSM drives: a comparative analysis , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[9]  M. F. Rahman,et al.  A direct torque controlled interior permanent magnet synchronous motor drive incorporating field weakening , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[10]  Seung-Ki Sul,et al.  Speed control of interior permanent magnet synchronous motor drive for the flux weakening operation , 1997 .

[11]  Yen-Shin Lai,et al.  Novel Voltage Trajectory Control for Flux Weakening Operation of Surface Mounted PMSM Drives , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[12]  Shigeo Morimoto,et al.  A Novel Method Of Maximum-power operation for IPMSMs in DTC system , 2009, 2009 13th European Conference on Power Electronics and Applications.

[13]  Shigeo Morimoto,et al.  Wide-speed operation of interior permanent magnet synchronous motors with high-performance current regulator , 1994 .

[14]  Shigeo Morimoto,et al.  A novel control scheme for maximum power operation of synchronous reluctance motors including maximum torque per flux control , 2009 .