Evaluation of a computerized measurement technique for joint alignment before and during periacetabular osteotomy.

Periacetabular osteotomy (PAO) is intended to treat a painful dysplastic hip. Manual radiological angle measurements are used to diagnose dysplasia and to define regions of insufficient femoral head coverage for planning PAO. No method has yet been described that recalculates radiological angles as the acetabular bone fragment is reoriented. In this study, we propose a technique for computationally measuring the radiological angles from a joint contact surface model segmented from CT-scan data. Using oblique image slices, we selected the lateral and medial edge of the acetabulum lunate to form a closed, continuous, 3D curve. The joint surface is generated by interpolating the curve, and the radiological angles are measured directly using the 3D surface. This technique was evaluated using CT data for both normal and dysplastic hips. Manual measurements made by three independent observers showed minor discrepancies between the manual observations and the computerized technique. Inter-observer error (mean difference +/- standard deviation) was 0.04 +/- 3.53 degrees for Observer 1; -0.46 +/- 3.13 degrees for Observer 2; and 0.42 +/- 2.73 degrees for Observer 3. The measurement error for the proposed computer method was -1.30 +/- 3.30 degrees . The computerized technique demonstrates sufficient accuracy compared to manual techniques, making it suitable for planning and intraoperative evaluation of radiological metrics for periacetabular osteotomy.

[1]  Hiroshi Tsumura,et al.  A computer simulation of rotational acetabular osteotomy for dysplastic hip joint: does the optimal transposition of the acetabular fragment exist? , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[2]  K. Tallroth,et al.  Developmental Dysplasia of the Hip 2: Adult , 2006 .

[3]  S B Murphy,et al.  Planning acetabular redirection osteotomies based on joint contact pressures. , 1999, Clinical orthopaedics and related research.

[4]  R. Dussault,et al.  Radiographic measurements of dysplastic adult hips , 1997, Skeletal Radiology.

[5]  R. Ganz,et al.  A new periacetabular osteotomy for the treatment of hip dysplasias. Technique and preliminary results. , 1988, Clinical orthopaedics and related research.

[6]  Randy Ellis,et al.  The Kingston Periacetabular Osteotomy Utilizing Computer Enhancement: A New Technique , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[7]  M Tannast,et al.  Tilt and Rotation Correction of Acetabular Version on Pelvic Radiographs , 2005, Clinical orthopaedics and related research.

[8]  I. Sharp ACETABULAR DYSPLASIA: The Acetabular Angle , 1961 .

[9]  F Langlotz,et al.  Computer Assistance for Pelvic Osteotomies , 1998, Clinical orthopaedics and related research.

[10]  T. Terjesen,et al.  Acetabular angles and femoral anteversion in dysplastic hips in adults: CT investigation. , 1991, Journal of computer assisted tomography.

[11]  M. DeKleuver Changes in load-bearing area after Ganz periacetabular osteotomy , 2005 .

[12]  Miroslav Sochor,et al.  Gradient of contact stress in normal and dysplastic human hips. , 2003, Medical engineering & physics.

[13]  Svein Anda,et al.  Computed tomography measurements of the acetabulum in adult dysplastic hips: which level is appropriate? , 2006, Skeletal Radiology.

[14]  E. Genda,et al.  A computer simulation study of normal and abnormal hip joint contact pressure , 2004, Archives of Orthopaedic and Trauma Surgery.

[15]  E. Chao,et al.  Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living. , 2006, Journal of biomechanics.

[16]  F Langlotz,et al.  The first twelve cases of computer assisted periacetabular osteotomy. , 1997, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[17]  T. Mieno,et al.  Determination of acetabular coverage of the femoral head with use of a single anteroposterior radiograph. A new computerized technique. , 1993, The Journal of bone and joint surgery. American volume.

[18]  Professor Dr. Dietrich Tönnis Congenital Dysplasia and Dislocation of the Hip in Children and Adults , 1987, Springer Berlin Heidelberg.

[19]  Jyri Lepistö,et al.  Computed tomography measurement of acetabular dimensions: Normal values for correction of dysplasia , 2006, Acta orthopaedica.

[20]  R P Veth,et al.  Acetabular coverage of the femoral head after triple pelvic osteotomy: no relation to outcome in 51 hips followed for 8-15 years. , 1999, Acta orthopaedica Scandinavica.

[21]  Alexander Wild,et al.  Computernavigierte Dreifach-Osteotomie des Beckens zur Behandlung der Hüftgelenkdysplasie , 2004 .

[22]  C. P. Duncan,et al.  Three-dimensional CT measurement of adult acetabular dysplasia: technique, preliminary results in normal subjects, and potential applications , 1998, Skeletal Radiology.

[23]  Marta Kersten,et al.  Fast assessment of acetabular coverage using stereoscopic volume rendering. , 2006, Studies in health technology and informatics.

[24]  P. Munk,et al.  CT evaluation of periacetabular osteotomies. , 2000, The Journal of bone and joint surgery. British volume.

[25]  G. Wiberg,et al.  Studies on dysplastic acetabula and congenital subluxation of the hip joint : with special reference to the complication of osteoarthritis , 1939 .

[26]  Robert Trousdale,et al.  Lessons learned after more than 250 periacetabular osteotomies , 2003, Acta orthopaedica Scandinavica.

[27]  R. Ganz,et al.  CT evaluation of coverage and congruency of the hip prior to osteotomy. , 1988, Clinical orthopaedics and related research.

[28]  Mehran Armand,et al.  Outcome of periacetabular osteotomy , 2005, Acta orthopaedica.

[29]  Kjeld Søballe,et al.  Changes in load-bearing area after Ganz periacetabular osteotomy evaluated by multislice CT scanning and stereology , 2004, Acta orthopaedica Scandinavica.

[30]  S B Murphy,et al.  Acetabular dysplasia in the adolescent and young adult. , 1990, Clinical orthopaedics and related research.